Real-time color-flow MRI at 3 T using variable-density spiral phase contrast

被引:12
|
作者
Liu, Chia-Ying [1 ,2 ,3 ]
Varadarajan, Padmini [4 ,5 ]
Pohost, Gerald M. [2 ,4 ,6 ]
Nayak, Krishna S. [2 ,4 ]
机构
[1] Univ Wisconsin, Dept Radiol, CSC, Madison, WI 53792 USA
[2] Univ So Calif, Viterbi Sch Engn, Los Angeles, CA USA
[3] Univ Wisconsin, Dept Med Phys, Madison, WI 53792 USA
[4] Univ So Calif, Keck Sch Med, Los Angeles, CA 90033 USA
[5] Loma Linda Med Ctr, Loma Linda, CA USA
[6] Salick Cardiovasc Ctr Inc, Beverly Hills, CA USA
关键词
3 T MRI; real-time MRI; phase contrast; spiral; color flow;
D O I
10.1016/j.mri.2008.01.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to demonstrate and evaluate the performance of real-time color-flow MRI at 3 T using variable-density spiral (VDS) phase contrast. Spiral phase contrast imaging was implemented within a flexible real-time interactive MRI system that provided continuous image reconstruction and an intuitive user interface. The pulse sequence consisted of a spectral-spatial excitation, bipolar gradient, spiral readout and gradient spoiler. VDSs were utilized to increase spatial and/or temporal resolution relative to uniform-density spirals (UDSs). Parameter choices were guided by specific applications. Sliding window reconstruction was used to achieve a maximum display rate of 40 frames/s. No breath-holding or gating was used. Our results demonstrated that real-time color-flow movies using UDS and VDS provided adequate visualization of intracardiac flow, carotid flow and proximal coronary flow in healthy volunteers. Average aortic outflow velocity measured at the aortic valve plane using VDS was 29.4% higher than that using UDS. Peak velocity measured in the common carotid artery using VDS was 9.8% higher than that using UDS, Published by Elsevier Inc.
引用
收藏
页码:661 / 666
页数:6
相关论文
共 50 条
  • [31] Blood and cerebrospinal fluid flow oscillations measured with real-time phase-contrast MRI: breathing mode matters
    Lagana, Maria Marcella
    Di Tella, Sonia
    Ferrari, Francesca
    Pelizzari, Laura
    Cazzoli, Marta
    Alperin, Noam
    Jin, Ning
    Zaca, Domenico
    Baselli, Giuseppe
    Baglio, Francesca
    [J]. FLUIDS AND BARRIERS OF THE CNS, 2022, 19 (01)
  • [32] Real-time image reconstruction for spiral MRI using fixed-point calculation
    Liao, JR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (07) : 690 - 698
  • [33] Real-time blood flow imaging using autocalibrated spiral sensitivity encoding
    Nezafat, R
    Kellman, P
    Derbyshire, JA
    McVeigh, ER
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (06) : 1557 - 1561
  • [34] Carotid artery flow as determined by real-time phase-contrast flow MRI and neurovascular ultrasound: A comparative study of healthy subjects
    Maier, Ilko L.
    Hofer, Sabine
    Joseph, Arun A.
    Merboldt, K. Dietmar
    Tan, Zhengguo
    Schregel, Katharina
    Knauth, Michael
    Baehr, Mathias
    Psychogios, Marios-Nikos
    Liman, Jan
    Frahm, Jens
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2018, 106 : 38 - 45
  • [35] Carotid Artery Flow as Determined by Real-Time Phase-Contrast Flow Mri and Neurovascular Ultrasound: a Comparative Study of Healthy Subjects
    Maier, Ilko
    Hofer, Sabine
    Joseph, Arun A.
    Merboldt, Klaus-Dietmar
    Tan, Zhengguo
    Schregel, Katharina
    Knauth, Michael
    Bahr, Mathias
    Psychogios, Marios-Nikos
    Liman, Jan
    Frahm, Jens
    [J]. STROKE, 2018, 49
  • [36] REAL-TIME FLOOD FLOW IMAGING BY SPIRAL SCAN PHASE-VELOCITY MAPPING
    GATEHOUSE, PD
    FIRMIN, DN
    COLLINS, S
    LONGMORE, DB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (05) : 504 - 512
  • [37] Real-time monitoring of solid-phase peptide synthesis using a variable bed flow reactor
    Sletten, Eric T.
    Nuno, Manuel
    Guthrie, Duncan
    Seeberger, Peter H.
    [J]. CHEMICAL COMMUNICATIONS, 2019, 55 (97) : 14598 - 14601
  • [38] Assessing Vascular Response To Exercise Using a Combination of Real-Time Spiral Phase Contrast MR and Noninvasive Blood Pressure Measurements
    Steeden, Jennifer A.
    Atkinson, David
    Taylor, Andrew M.
    Muthurangu, Vivek
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (04) : 997 - 1003
  • [39] REAL-TIME COLOR DEBUGGING OF OPTICAL-IMAGES PSEUDOCOLORING DENSITY WITH PHASE MODULATION
    ZHOU, K
    CHEN, ZP
    ZHONG, YB
    [J]. CHINESE PHYSICS, 1990, 10 (02): : 411 - 417
  • [40] Real-Time Phase-Contrast MRI to Monitor Cervical Blood and Cerebrospinal Fluid Flow Beat-by-Beat Variability
    Baselli, Giuseppe
    Fasani, Federica
    Pelizzari, Laura
    Cazzoli, Marta
    Baglio, Francesca
    Lagana, Maria Marcella
    [J]. BIOSENSORS-BASEL, 2022, 12 (06):