Accuracy of dental implant surgery using dynamic navigation and robotic systems: An in vitro study

被引:64
|
作者
Tao, Baoxin [1 ]
Feng, Yuan [2 ]
Fan, Xingqi [3 ]
Zhuang, Minjie [1 ]
Chen, Xiaojun [3 ]
Wang, Feng [4 ]
Wu, Yiqun [1 ]
机构
[1] Shanghai Jiao Tong Univ, Coll Stomatol,Sch Med,Shanghai Key Lab Stomatol,S, Chinese Acad Med Sci,Res Unit Oral & Maxillofacia, Natl Ctr Stomatol,Natl Clin Res Ctr Oral Dis,Dept, 280 Mohe Rd, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Mech Engn, Dongchuan Rd 800, Shanghai 200240, Peoples R China
[3] Shanghai Jiao Tong Univ, Inst Biomed Mfg & Life Qual Engn, Sch Mech Engn, State Key Lab Mech Syst & Vibrat, Room 805,Dongchuan Rd 800, Shanghai 200240, Peoples R China
[4] Shanghai Jiao Tong Univ, Dept Oral Implantol,Sch Med,Res Unit Oral & Maxil, Chinese Acad Med Sci,Shanghai Key Lab Stomatol,Sh, Coll Stomatol,Natl Ctr Stomatol,Natl Clin Res Ctr, 639 Zhizaoju Rd, Shanghai, Peoples R China
关键词
Accuracy; Computer-assisted surgery; Robot-assisted surgery; Phantom study; CURRENT STATE; PLACEMENT; METAANALYSIS; GUIDE;
D O I
10.1016/j.jdent.2022.104170
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare the accuracy of dental implant placement using a dynamic navigation and a robotic system. Methods: Eighty three-dimensional (3D) printed phantoms, including edentulous and partially edentulous jaws, were assigned to two groups: a dynamic navigation system (Beidou-SNS) group and a robotic system (Hybrid Robotic System for Dental Implant Surgery, HRS-DIS) group. The entry, exit and angle deviations of the implants in 3D world were measured after pre-operative plans and postoperative cone-beam computed tomography (CBCT) fusion. A linear mixed model with a random intercept was applied, and a p value <.05 was considered statistically significant. Results: A total of 480 implants were placed in 80 phantoms. The comparison deviation of the dynamic navigation system and robotic system groups showed a mean (+/- SD) entry deviation of 0.96 +/- 0.57 mm vs. 0.83 +/- 0.55 mm (p=0.04), a mean exit deviation of 1.06 +/- 0.59 mm vs. 0.91 +/- 0.56 mm (p=0.04), and a mean angle deviation of 2.41 +/- 1.42 degrees vs. 1 +/- 0.48 degrees (p<0.00). Conclusions: The implant positioning accuracy of the robotic system was superior to that of the dynamic navigation system, suggesting that this prototype robotic system (HRS-DIS) could be a promising tool in dental implant surgery.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] A Comparative Prospective Study on the Accuracy and Efficiency of Autonomous Robotic System Versus Dynamic Navigation System in Dental Implant Placement
    Yu, Muqiao
    Luo, Yilin
    Li, Bolin
    Xu, Lingqiao
    Yang, Xingmei
    Man, Yi
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2025, 52 (02) : 280 - 288
  • [22] Comparison of robotic system and dynamic navigation for zygomatic implant placement: An in vitro study
    Guo, Houzuo
    Jiang, Xi
    Lin, Ye
    JOURNAL OF DENTISTRY, 2024, 150
  • [23] Accuracy of a Dynamic Dental Implant Navigation System in a Private Practice
    Stefanelli, Luigi, V
    DeGroot, Bradley S.
    Lipton, David, I
    Mandelaris, George A.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (01) : 205 - 213
  • [24] Accuracy of Computer-Aided Dynamic Navigation Compared to Computer-Aided Static Navigation for Dental Implant Placement: An In Vitro Study
    Mediavilla Guzman, Alfonso
    Riad Deglow, Elena
    Zubizarreta-Macho, Alvaro
    Agustin-Panadero, Ruben
    Hernandez Montero, Sofia
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (12)
  • [25] Implant Placement Accuracy Using Dynamic Navigation
    Block, Michael S.
    Emery, Robert W.
    Lank, Kathryn
    Ryan, James
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) : 92 - 99
  • [26] Accuracy and efficiency of a calibration approach in dynamic navigation for implant placement: An in vitro study
    Pei, Xiyan
    Weng, Jinlong
    Sun, Feng
    Ma, Yu
    Iao, Siniong
    Liu, Xiaoqiang
    JOURNAL OF DENTAL SCIENCES, 2024, 19 (01) : 51 - 57
  • [27] Dynamic Navigation in Dental Implantology: The Influence of Surgical Experience on Implant Placement Accuracy and Operating Time. An in Vitro Study
    Pellegrino, Gerardo
    Bellini, Pierantonio
    Cavallini, Pier Francesco
    Ferri, Agnese
    Zacchino, Andrea
    Taraschi, Valerio
    Marchetti, Claudio
    Consolo, Ugo
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (06)
  • [28] Effect of Clinical Experience on Accuracy of Implant Placement Using Dynamic Navigation and Static Guidance: An In Vitro Study
    Fang, Qiao
    Lozada, Jaime
    Kan, Joseph
    Al-Ardah, Aladdin
    Li, Yiming
    JOURNAL OF ORAL IMPLANTOLOGY, 2024, 50 (06) : 626 - 635
  • [29] Influence of Metal Guide Sleeves on the Accuracy and Precision of Dental Implant Placement Using Guided Implant Surgery: An In Vitro Study
    Adams, Coleman R.
    Ammoun, Rami
    Deeb, George R.
    Bencharit, Sompop
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (01): : 62 - 70
  • [30] Accuracy of dental implant placement using augmented reality-based navigation, static computer assisted implant surgery, and the free-hand method: An in vitro study
    Kivovics, Marton
    Takacs, Anna
    Penzes, Dorottya
    Nemeth, Orsolya
    Mijiritsky, Eitan
    JOURNAL OF DENTISTRY, 2022, 119