Accuracy of dental implant surgery using dynamic navigation and robotic systems: An in vitro study

被引:64
|
作者
Tao, Baoxin [1 ]
Feng, Yuan [2 ]
Fan, Xingqi [3 ]
Zhuang, Minjie [1 ]
Chen, Xiaojun [3 ]
Wang, Feng [4 ]
Wu, Yiqun [1 ]
机构
[1] Shanghai Jiao Tong Univ, Coll Stomatol,Sch Med,Shanghai Key Lab Stomatol,S, Chinese Acad Med Sci,Res Unit Oral & Maxillofacia, Natl Ctr Stomatol,Natl Clin Res Ctr Oral Dis,Dept, 280 Mohe Rd, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Mech Engn, Dongchuan Rd 800, Shanghai 200240, Peoples R China
[3] Shanghai Jiao Tong Univ, Inst Biomed Mfg & Life Qual Engn, Sch Mech Engn, State Key Lab Mech Syst & Vibrat, Room 805,Dongchuan Rd 800, Shanghai 200240, Peoples R China
[4] Shanghai Jiao Tong Univ, Dept Oral Implantol,Sch Med,Res Unit Oral & Maxil, Chinese Acad Med Sci,Shanghai Key Lab Stomatol,Sh, Coll Stomatol,Natl Ctr Stomatol,Natl Clin Res Ctr, 639 Zhizaoju Rd, Shanghai, Peoples R China
关键词
Accuracy; Computer-assisted surgery; Robot-assisted surgery; Phantom study; CURRENT STATE; PLACEMENT; METAANALYSIS; GUIDE;
D O I
10.1016/j.jdent.2022.104170
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare the accuracy of dental implant placement using a dynamic navigation and a robotic system. Methods: Eighty three-dimensional (3D) printed phantoms, including edentulous and partially edentulous jaws, were assigned to two groups: a dynamic navigation system (Beidou-SNS) group and a robotic system (Hybrid Robotic System for Dental Implant Surgery, HRS-DIS) group. The entry, exit and angle deviations of the implants in 3D world were measured after pre-operative plans and postoperative cone-beam computed tomography (CBCT) fusion. A linear mixed model with a random intercept was applied, and a p value <.05 was considered statistically significant. Results: A total of 480 implants were placed in 80 phantoms. The comparison deviation of the dynamic navigation system and robotic system groups showed a mean (+/- SD) entry deviation of 0.96 +/- 0.57 mm vs. 0.83 +/- 0.55 mm (p=0.04), a mean exit deviation of 1.06 +/- 0.59 mm vs. 0.91 +/- 0.56 mm (p=0.04), and a mean angle deviation of 2.41 +/- 1.42 degrees vs. 1 +/- 0.48 degrees (p<0.00). Conclusions: The implant positioning accuracy of the robotic system was superior to that of the dynamic navigation system, suggesting that this prototype robotic system (HRS-DIS) could be a promising tool in dental implant surgery.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Dynamic Navigation for Dental Implant Placement
    Pinter, Gabor Tamas
    Decker, Roland
    Szenasi, Gabor
    Barabas, Peter
    Huszar, Tamas
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (187):
  • [42] The effect of implant surgery experience on the learning curve of a dynamic navigation system: an in vitro study
    Xu, Zonghe
    Zhou, Lin
    Zheng, Ming
    Lin, Yanjun
    Huang, Wenxiu
    Chen, Jiang
    Li, Yan
    Wu, Dong
    BMC ORAL HEALTH, 2023, 23 (01)
  • [43] Accuracy of haptic robotic guidance of dental implant surgery for completely edentulous arches
    Bolding, Scotty L.
    Reebye, Uday N.
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04): : 639 - 647
  • [44] Learning curve of dynamic navigation-assisted zygomatic implant surgery: An in vitro study
    Wang, Wenying
    Zhuang, Minjie
    Tao, Baoxin
    Wang, Feng
    Wu, Yiqun
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (01): : 178e1 - 178e12
  • [45] The effect of implant surgery experience on the learning curve of a dynamic navigation system: an in vitro study
    Zonghe Xu
    Lin Zhou
    Ming Zheng
    Yanjun Lin
    Wenxiu Huang
    Jiang Chen
    Yan Li
    Dong Wu
    BMC Oral Health, 23
  • [46] Effect of a dynamic navigation device on the accuracy of implant placement in the completely edentulous mandible: An in vitro study
    Feng, Yuzhang
    Yao, Yufei
    Yang, Xingmei
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (05): : 731 - 737
  • [47] The accuracy of a novel image-guided hybrid robotic system for dental implant placement: An in vitro study
    Tao, Baoxin
    Feng, Yuan
    Fan, Xingqi
    Lan, Kengliang
    Zhuang, Minjie
    Wang, Shigang
    Wang, Feng
    Chen, Xiaojun
    Wu, Yiqun
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2023, 19 (01):
  • [48] Accuracy of dynamic implant navigation surgery performed by a novice operator A preliminary study in a cadaveric model
    Marques-Guasch, Jordi
    Rodriguez-Bauza, Rafel
    Satorres-Nieto, Marta
    Hom-Lay, Wang
    Hernandez-Alfaro, Federico
    Gargallo-Albiol, Jordi
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2022, 25 (04) : 377 - 385
  • [49] Accuracy of an autonomous dental implant robotic system versus static guide-assisted implant surgery: A retrospective clinical study
    Jia, Shasha
    Wang, Guowei
    Zhao, Yimin
    Wang, Xiaojing
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (03): : 771 - 779
  • [50] Accuracy of implant placement using a mixed reality-based dynamic navigation system versus static computer-assisted and freehand surgery: An in Vitro study
    Shusterman, Ariel
    Nashef, Rizan
    Tecco, Simona
    Mangano, Carlo
    Lerner, Henriette
    Mangano, Francesco Guido
    JOURNAL OF DENTISTRY, 2024, 146