Comparison of robotic system and dynamic navigation for zygomatic implant placement: An in vitro study

被引:1
|
作者
Guo, Houzuo [1 ]
Jiang, Xi [1 ]
Lin, Ye [1 ]
机构
[1] Peking Univ, Sch & Hosp Stomatol, Dept Oral Implantol, 22 Zhongguancun South St, Beijing 10081, Peoples R China
关键词
Zygomatic implant; Robotic system; Dynamic navigation system; Surgical accuracy; In vitro study; Maxillary atrophy rehabilitation; ACCURACY; MANAGEMENT; BONE; REHABILITATION; SURGERY; MAXILLA; ATROPHY;
D O I
10.1016/j.jdent.2024.105329
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare the accuracy of robotic and dynamic navigation systems in assisting zygomatic implant (ZI) using an in vitro model experiment. Methods: Preoperative cone-beam computed tomography (CBCT) images of patients who underwent ZI treatment between 2011 and 2023 were collected from local databases. Corresponding three-dimensional resin models were printed and assigned to two groups: the robotic and dynamic navigation system groups. Following preoperative plans, ZIs were placed in the models with the assistance of either a robotic or dynamic navigation system. Deviations in the in vitro navigation surgery were measured and compared between the groups. Results: A total of 110 ZIs were placed in 56 models, with 55 ZIs in each group. No significant differences were observed in entry and angle deviations between the groups (p>0.05). However, the exit deviation in the robotic system group (2.39+1.24 mm) was larger than that in the dynamic navigation group (1.83+1.25 mm) (p<0.05). On the exit side, the Z-axis deviation in the robotic group (left: -0.28+1.43 mm, right: -0.21+1.30 mm) was smaller than that in the dynamic navigation group (left: 0.76+1.11 mm, right: 0.85+1.52 mm) (p<0.05), while no significant differences were found in X- and Y-axis deviations (p>0.05). Conclusions: Compared with the dynamic navigation system, the robotic system can effectively prevent ZI overextension. However, its accuracy on the exit side is slightly lower than that of the dynamic navigation system. Clinical Significance: This preliminary in vitro study showed that the accuracy of the robotic system was slightly inferior to that of the dynamic navigation system in terms of exit deviation when used in ZI placement. Further clinical studies are required to confirm these findings.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Accuracy of Zygomatic Implant Placement Using Task-Autonomous Robotic System or Dynamic Navigation: An In Vitro Study
    Chen, Jinyan
    Tao, Baoxin
    Yu, Xinbo
    Wu, Yiqun
    Wang, Feng
    CLINICAL ORAL IMPLANTS RESEARCH, 2025, 36 (02) : 178 - 190
  • [2] A hybrid robotic system for zygomatic implant placement based on mixed reality navigation
    Fan, Xingqi
    Feng, Yuan
    Tao, Baoxin
    Shen, Yihan
    Wu, Yiqun
    Chen, Xiaojun
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2024, 249
  • [3] Reliability and accuracy of dynamic navigation for zygomatic implant placement
    Wu, Yiqun
    Tao, Baoxin
    Lan, Kengliang
    Shen, Yihan
    Huang, Wei
    Wang, Feng
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (04) : 362 - 376
  • [4] Dynamic navigation-guided robotic placement of zygomatic implants
    Al-Jarsha, Mohammed Y.
    Diao, Yufeng
    Zhao, Guodong
    Imran, Muhammad A.
    Ayoub, Ashraf F.
    Robertson, Douglas P.
    Naudi, Kurt B.
    JOURNAL OF DENTISTRY, 2025, 153
  • [5] Accuracy of a Computer-Aided Dynamic Navigation System in the Placement of Zygomatic Dental Implants: An In Vitro Study
    Gonzalez Rueda, Juan Ramon
    Garcia Avila, Irene
    de Paz Hermoso, Victor Manuel
    Riad Deglow, Elena
    Zubizarreta-Macho, Alvaro
    Pato Mourelo, Jesus
    Montero Martin, Javier
    Hernandez Montero, Sofia
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (05)
  • [6] Minimally Invasive Navigation-Guided Quad Zygomatic Implant Placement: A Comparative In Vitro Study
    Fan, Shengchi
    Gielisch, Matthias W.
    Diaz, Leonardo
    Thiem, Daniel G. E.
    Al-Nawas, Bilal
    Kaemmerer, Peer W.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (02) : 367 - 373
  • [7] Effect of the Configurations of Fiducial Markers on the Accuracy of Surgical Navigation in Zygomatic Implant Placement: An In Vitro Study
    Fan, Shengchi
    Hung, Kuofeng
    Bornstein, Michael M.
    Huang, Wei
    Wang, Feng
    Wu, Yiqun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (01) : 85 - 90
  • [8] Learning curve of dynamic navigation-assisted zygomatic implant surgery: An in vitro study
    Wang, Wenying
    Zhuang, Minjie
    Tao, Baoxin
    Wang, Feng
    Wu, Yiqun
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (01): : 178e1 - 178e12
  • [9] Accuracy of immediate dental implant placement with task-autonomous robotic system and navigation system: An in vitro study
    Chen, Jinyan
    Zhuang, Minjie
    Tao, Baoxin
    Wu, Yiqun
    Ye, Lijuan
    Wang, Feng
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 973 - 983
  • [10] Dynamic navigation for zygomatic implant placement: A randomized clinical study comparing the flapless versus the conventional approach
    Bhalerao, Ashwini
    Marimuthu, Madhulaxmi
    Wahab, Abdul
    Ayoub, Ashraf
    JOURNAL OF DENTISTRY, 2023, 130