Comparison of robotic system and dynamic navigation for zygomatic implant placement: An in vitro study

被引:1
|
作者
Guo, Houzuo [1 ]
Jiang, Xi [1 ]
Lin, Ye [1 ]
机构
[1] Peking Univ, Sch & Hosp Stomatol, Dept Oral Implantol, 22 Zhongguancun South St, Beijing 10081, Peoples R China
关键词
Zygomatic implant; Robotic system; Dynamic navigation system; Surgical accuracy; In vitro study; Maxillary atrophy rehabilitation; ACCURACY; MANAGEMENT; BONE; REHABILITATION; SURGERY; MAXILLA; ATROPHY;
D O I
10.1016/j.jdent.2024.105329
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare the accuracy of robotic and dynamic navigation systems in assisting zygomatic implant (ZI) using an in vitro model experiment. Methods: Preoperative cone-beam computed tomography (CBCT) images of patients who underwent ZI treatment between 2011 and 2023 were collected from local databases. Corresponding three-dimensional resin models were printed and assigned to two groups: the robotic and dynamic navigation system groups. Following preoperative plans, ZIs were placed in the models with the assistance of either a robotic or dynamic navigation system. Deviations in the in vitro navigation surgery were measured and compared between the groups. Results: A total of 110 ZIs were placed in 56 models, with 55 ZIs in each group. No significant differences were observed in entry and angle deviations between the groups (p>0.05). However, the exit deviation in the robotic system group (2.39+1.24 mm) was larger than that in the dynamic navigation group (1.83+1.25 mm) (p<0.05). On the exit side, the Z-axis deviation in the robotic group (left: -0.28+1.43 mm, right: -0.21+1.30 mm) was smaller than that in the dynamic navigation group (left: 0.76+1.11 mm, right: 0.85+1.52 mm) (p<0.05), while no significant differences were found in X- and Y-axis deviations (p>0.05). Conclusions: Compared with the dynamic navigation system, the robotic system can effectively prevent ZI overextension. However, its accuracy on the exit side is slightly lower than that of the dynamic navigation system. Clinical Significance: This preliminary in vitro study showed that the accuracy of the robotic system was slightly inferior to that of the dynamic navigation system in terms of exit deviation when used in ZI placement. Further clinical studies are required to confirm these findings.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Learning Curve and Comparison of Dynamic Implant Placement Accuracy Using a Navigation System in Young Professionals
    Spille, Johannes
    Helmstetter, Eva
    Kuebel, Paul
    Weitkamp, Jan-Tobias
    Wagner, Juliane
    Wieker, Henning
    Naujokat, Hendrik
    Floerke, Christian
    Wiltfang, Joerg
    Guelses, Aydin
    DENTISTRY JOURNAL, 2022, 10 (10)
  • [32] Accuracy of implant placement via dynamic navigation and autonomous robotic computer-assisted implant surgery methods: A retrospective study
    Zhang, Sihui
    Cai, Qin
    Chen, Weiyi
    Lin, Yuxuan
    Gao, Yan
    Wu, Dong
    Chen, Jiang
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (02) : 220 - 229
  • [33] Dynamic navigation for prosthetically driven zygomatic implant placement in extensive maxillary defects: Results of a prospective case series
    Wang, Feng
    Fan, Shengchi
    Huang, Wei
    Shen, Yihan
    Li, Chaolun
    Wu, Yiqun
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (04) : 435 - 443
  • [34] Assessment of the Accuracy of Two Different Dynamic Navigation System Registration Methods for Dental Implant Placement in the Posterior Area: An In Vitro Study
    Wei, Tai
    Ma, Feifei
    Sun, Feng
    Ma, Yu
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (01):
  • [35] In Vitro Comparison of Time and Accuracy of Implant Placement Using Trephine and Conventional Drilling Techniques Under Dynamic Navigation
    Deeb, Janina Golob
    Frantar, Anja
    Deeb, George R.
    Carrico, Caroline K.
    Rener-Sitar, Ksenija
    JOURNAL OF ORAL IMPLANTOLOGY, 2021, 47 (03) : 199 - 204
  • [36] Evaluation of a dynamic navigation system for training students in dental implant placement
    Zhan, Yalin
    Wang, Miaozhen
    Cheng, Xueyuan
    Li, Yi
    Shi, Xiaorui
    Liu, Feng
    JOURNAL OF DENTAL EDUCATION, 2021, 85 (02) : 120 - 127
  • [37] A novel application of dynamic guided navigation system in immediate implant placement
    Kuo, Po-Jan
    Lin, Chi-Yu
    Hung, Tsung-Fu
    Chiu, Hsien-Chung
    Kuo, Hsin-Yu
    JOURNAL OF DENTAL SCIENCES, 2022, 17 (01) : 354 - 360
  • [38] Dynamic Navigation System for Immediate Implant Placement in the Maxillary Aesthetic Region
    Battista, Eric
    Gasparro, Roberta
    Cacciola, Maria
    Sammartino, Gilberto
    Marenzi, Gaetano
    APPLIED SCIENCES-BASEL, 2022, 12 (11):
  • [39] Accuracy of 3 calibration methods of computer-assisted dynamic navigation for implant placement: An in vitro study
    Pei, Xiyan
    Liu, Xiaoqiang
    Iao, Siniong
    Ma, Feifei
    Li, Hong
    Sun, Feng
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (04): : 668 - 674
  • [40] Effect of Clinical Experience on Accuracy of Implant Placement Using Dynamic Navigation and Static Guidance: An In Vitro Study
    Fang, Qiao
    Lozada, Jaime
    Kan, Joseph
    Al-Ardah, Aladdin
    Li, Yiming
    JOURNAL OF ORAL IMPLANTOLOGY, 2024, 50 (06) : 626 - 635