Effect of contact lens surface properties on comfort, tear stability and ocular physiology

被引:58
|
作者
Vidal-Rohr, Maria [1 ,2 ]
Wolffsohn, James S. [1 ]
Davies, Leon N. [1 ]
Cervino, Alejandro [2 ]
机构
[1] Aston Univ, Ophthalm Res Grp, Birmingham B4 7ET, W Midlands, England
[2] Univ Valencia, Dept Opt & Optometry & Vis Sci, Optometry Res Grp, E-46100 Burjassot, Spain
来源
CONTACT LENS & ANTERIOR EYE | 2018年 / 41卷 / 01期
基金
英国工程与自然科学研究理事会;
关键词
Discomfort; Coating; Soft contact lens; Tear film; Lubricity; Coefficient of friction; TFOS INTERNATIONAL WORKSHOP; DRY EYE DISEASE; CLINICAL-EVALUATION; DISCOMFORT REPORT; NORTH-AMERICA; WEARERS; FILM; SYMPTOMS; SUBCOMMITTEE;
D O I
10.1016/j.clae.2017.09.009
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: Retrospective analysis of different contact lens wearing groups suggests lens surface lubricity is the main factor influencing contact lens comfort. However, the examined commercially available contact lenses differ in material and design as well as surface properties. Hence this study isolates the contribution of lens surface properties using an ultra-thin coating technology. Methods: Nineteen habitual contact lens wearers (21.6 +/- 1.7 years) wore formofilcon B soft monthly disposable contact lenses with and without coating technology modified surface properties for a month each in a randomised double-masked cross-over study. Objective non-invasive: breakup time (NIKBUT), NIKBUT average and ocular redness (Jenvis grading scale) were evaluated (Keratograph 5M) after 1 week and 1 month of wear. Symptoms were assessed using the Contact Lens Dry Eye Questionnaire (CLDEQ-8); perceived vision quality and subjective lens comfort at insertion, mid-day and end of the day were rated with four Visual Analog Scales. Results: Perceived visual quality (F = 5.049, p = 0.037), contact lens dry eye symptoms (F = 14.408, p = 0.001) and subjective lens comfort (F = 28.447, p < 0.001) were better for coated compared to uncoated lenses. The surface coating postponed the lens dewetting (F = 8.518, p = 0.009) and increased the pre-lens tear film stability (F = 5.626, p = 0.029), but bulbar (F = 0.340, p = 0.567) and limbal (F = 0.110, p = 0.744) redness were similar for both contact lenses. No parameter changed significantly between a weeks' and months' wear (p > 0.05). Lens surface wettability and ocular redness were not correlated to changes in symptoms (p > 0.05). Conclusion: As previously hypothesised, enhancing the physical surface properties of a soft contact lens improves subjectively rated wearer comfort, which, in turn, should result in reduced contact lens discontinuation.
引用
收藏
页码:117 / 121
页数:5
相关论文
共 50 条
  • [21] Asymptomatic versus symptomatic young contact lens wearers: differences in corneal sensitivity, ocular surface temperature, tear stability and blinking rate
    Carmen Acosta, M.
    Angel Pastor-Zaplana, Jose
    Gallar, Juana
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [22] Changes in tear film physiology during soft contact lens wear
    Mousavi, Maryam
    Garaszczuk, Izabela
    Szczesna-Iskander, Dorota H.
    Iskander, D. Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [23] The ocular surface, the tear film, and the wettability of contact lenses
    Morris, CA
    Holden, BA
    Papas, E
    Griesser, HJ
    Bolis, S
    Anderton, P
    Carney, F
    LACRIMAL GLAND, TEAR FILM, AND DRY EYE SYNDROMES 2: BASIC SCIENCE AND CLINICAL RELEVANCE, 1998, 438 : 717 - 722
  • [24] Ocular surface assessment in soft contact lens wearers; the contribution of tear osmolarity among other tests
    Muselier-Mathieu, Aurore
    Bron, Alain M.
    Mathieu, Benigne
    Souchier, Maxime
    Brignole-Baudouin, Francoise
    Acar, Niyazi
    Bretillon, Lionel
    Creuzot-Garcher, Catherine
    ACTA OPHTHALMOLOGICA, 2014, 92 (04) : 364 - 369
  • [25] The Effect of Face Mask Wear on the Ocular Surface and Contact Lens Microbiome
    Ozkan, Jerome
    Majzoub, Marwan E.
    Khan, Mahjabeen
    Coroneo, Minas
    Thomas, Torsten
    Willcox, Mark
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (11): : 467 - 474
  • [26] Effect of posterior chamber phakic refractive lens implantation on the ocular surface and tear film
    Yan, Zhuxuan
    Yan, Zhenguo
    Lv, Yang
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [27] The Impact of Visual Guided Order Picking on Ocular Comfort, Ocular Surface and Tear Function
    Klein-Theyer, Angelika
    Horwath-Winter, Jutta
    Rabensteiner, Dieter Franz
    Schwantzer, Gerold
    Wultsch, Georg
    Aminfar, Haleh
    Heidinger, Andrea
    Boldin, Ingrid
    PLOS ONE, 2016, 11 (06):
  • [28] The impact of punctal occlusion on soft contact lens wearing comfort and the tear film
    Geldis, Julia R.
    Nichols, Jason J.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2008, 34 (05): : 261 - 265
  • [29] Ocular surface health with contact lens wear
    Shovlin, Joseph P.
    CONTACT LENS & ANTERIOR EYE, 2013, 36 : S14 - S21
  • [30] Contact lens care and ocular surface homeostasis
    Efron, Nathan
    CONTACT LENS & ANTERIOR EYE, 2013, 36 : S9 - S13