Effect of posterior chamber phakic refractive lens implantation on the ocular surface and tear film

被引:0
|
作者
Yan, Zhuxuan [1 ,2 ]
Yan, Zhenguo [1 ]
Lv, Yang [3 ]
机构
[1] Lanzhou Huaxia Eye Hosp, Lanzhou 730000, Gansu, Peoples R China
[2] Gansu Univ Tradit Chinese Med, Clin Med Coll 1, Lanzhou 730000, Gansu, Peoples R China
[3] 940th Hosp Chinese Peoples Liberat Army Joint Sup, Dept Ophthalmol, Lanzhou 730000, Gansu, Peoples R China
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
关键词
Dry eye; Phakic intraocular lens implantation; Tear film; SURGERY;
D O I
10.1038/s41598-024-72552-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To evaluate changes in dry eye-related parameters after posterior chamber phakic refractive lens (PC-PRL) implantation. This prospective study included 21 highly myopic patients (39 eyes) who underwent PC-PRL implantation at Lanzhou Huaxia Eye Hospital between January 2021 and June 2022, with a 3-month postoperative follow-up. In addition to routine preoperative examinations, dry eye assessments were conducted preoperatively and at 1 week, 1 month, and 3 months postoperatively. These assessments included the Ocular Surface Disease Index (OSDI) questionnaire score, non-invasive first tear break-up time (NIF-BUT), non-invasive average tear break-up time (NIA-BUT), tear meniscus height (TMH), meibomian gland loss (MGL) rate, and Schirmer I test (SIt). Repeated measures ANOVA was used to compare the differences in parameters across different time points, with pairwise comparisons conducted using the LSD-t test. After grouping, the Student's t-test was applied to compare normally distributed data, while the Mann-Whitney U test was used for non-normally distributed data. Categorical data were analyzed using the chi-square test. A total of 21 patients (39 eyes) were included, comprising 10 males (19 eyes) and 11 females (20 eyes), aged 19 to 49 years (33.76 +/- 7.87). All patients completed the 3-month follow-up. Significant differences in OSDI scores were observed pre- and post-surgery (P=0.008), with a peak at one week post-surgery (P<0.001), then stabilizing at one and three months post-surgery. Postoperative NIF-BUT and NIA-BUT significantly decreased (P<0.001 for both) but returned to preoperative levels within three months. There were no significant changes in TMH, MGL, or SIt postoperatively (P>0.05). Significant differences in dry eye parameters were observed between the dry eye and control groups before and after surgery (P<0.001). PC-PRL implantation impacts tear film stability on the ocular surface after surgery, leading to varying degrees of dry eye symptoms in patients. After surgery, all dry eye parameters return to their preoperative levels within three months.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Changes of ocular biometry in eyes with posterior chamber phakic intraocular lens implantation
    Kayhan, B.
    Coskunseven, E.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2022, 45 (04): : 377 - 383
  • [2] Bilateral giant retinal tear following posterior chamber phakic intraocular lens implantation
    Navarro, R
    Gris, O
    Broc, L
    Corcóstegui, B
    JOURNAL OF REFRACTIVE SURGERY, 2005, 21 (03) : 298 - 300
  • [3] The posterior chamber phakic refractive lens (PRL): a review
    Perez-Cambrodi, R. J.
    Pinero, D. P.
    Ferrer-Blasco, T.
    Cervino, A.
    Brautaset, R.
    EYE, 2013, 27 (01) : 14 - 21
  • [4] A posterior chamber phakic refractive lens dislocated into the vitreous
    Ma, Mingming
    Xiao, Qirui
    Wang, Aijun
    Zheng, Zhi
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (05) : NP21 - NP24
  • [5] The posterior chamber phakic refractive lens (PRL): a review
    R J Pérez-Cambrodí
    D P Piñero
    T Ferrer-Blasco
    A Cerviño
    R Brautaset
    Eye, 2013, 27 : 14 - 21
  • [6] Implantation of a Phakic Posterior Chamber Lens in Eyes with Keratoconus
    Khoramnia, Ramin
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2020, 237 (09) : 1102 - 1106
  • [7] Posterior Chamber Phakic Intraocular Lens Implantation for Refractive Correction in Corneal Ectatic Disorders: A Review
    Kalra, Nidhi
    Asif, Mohamed Ibrahime
    Bafna, Rahul Kumar
    Sharma, Namrata
    Sinha, Rajesh
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (05) : 351 - +
  • [8] Lens opacities after posterior chamber phakic intraocular lens implantation
    Sánchez-Galeana, CA
    Smith, RJ
    Sanders, DR
    Rodríguez, FX
    Litwak, S
    Montes, M
    Chayet, AS
    OPHTHALMOLOGY, 2003, 110 (04) : 781 - 785
  • [9] Posterior chamber phakic intraocular lens implantation for high myopia
    沈晔
    杜持新
    顾扬顺
    王竞
    ChineseMedicalJournal, 2003, (10)
  • [10] Posterior chamber phakic intraocular lens implantation for high myopia
    Shen, Y
    Du, CX
    Gu, YS
    Wang, J
    CHINESE MEDICAL JOURNAL, 2003, 116 (10) : 1523 - 1526