Effect of posterior chamber phakic refractive lens implantation on the ocular surface and tear film

被引:0
|
作者
Yan, Zhuxuan [1 ,2 ]
Yan, Zhenguo [1 ]
Lv, Yang [3 ]
机构
[1] Lanzhou Huaxia Eye Hosp, Lanzhou 730000, Gansu, Peoples R China
[2] Gansu Univ Tradit Chinese Med, Clin Med Coll 1, Lanzhou 730000, Gansu, Peoples R China
[3] 940th Hosp Chinese Peoples Liberat Army Joint Sup, Dept Ophthalmol, Lanzhou 730000, Gansu, Peoples R China
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
关键词
Dry eye; Phakic intraocular lens implantation; Tear film; SURGERY;
D O I
10.1038/s41598-024-72552-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To evaluate changes in dry eye-related parameters after posterior chamber phakic refractive lens (PC-PRL) implantation. This prospective study included 21 highly myopic patients (39 eyes) who underwent PC-PRL implantation at Lanzhou Huaxia Eye Hospital between January 2021 and June 2022, with a 3-month postoperative follow-up. In addition to routine preoperative examinations, dry eye assessments were conducted preoperatively and at 1 week, 1 month, and 3 months postoperatively. These assessments included the Ocular Surface Disease Index (OSDI) questionnaire score, non-invasive first tear break-up time (NIF-BUT), non-invasive average tear break-up time (NIA-BUT), tear meniscus height (TMH), meibomian gland loss (MGL) rate, and Schirmer I test (SIt). Repeated measures ANOVA was used to compare the differences in parameters across different time points, with pairwise comparisons conducted using the LSD-t test. After grouping, the Student's t-test was applied to compare normally distributed data, while the Mann-Whitney U test was used for non-normally distributed data. Categorical data were analyzed using the chi-square test. A total of 21 patients (39 eyes) were included, comprising 10 males (19 eyes) and 11 females (20 eyes), aged 19 to 49 years (33.76 +/- 7.87). All patients completed the 3-month follow-up. Significant differences in OSDI scores were observed pre- and post-surgery (P=0.008), with a peak at one week post-surgery (P<0.001), then stabilizing at one and three months post-surgery. Postoperative NIF-BUT and NIA-BUT significantly decreased (P<0.001 for both) but returned to preoperative levels within three months. There were no significant changes in TMH, MGL, or SIt postoperatively (P>0.05). Significant differences in dry eye parameters were observed between the dry eye and control groups before and after surgery (P<0.001). PC-PRL implantation impacts tear film stability on the ocular surface after surgery, leading to varying degrees of dry eye symptoms in patients. After surgery, all dry eye parameters return to their preoperative levels within three months.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Posterior chamber phakic intraocular lens for hyperopia
    Sanders, DR
    Martin, RG
    Brown, DC
    Shepherd, J
    Deitz, MR
    DeLuca, MC
    JOURNAL OF REFRACTIVE SURGERY, 1999, 15 (03) : 309 - 315
  • [42] Posterior chamber silicone phakic intraocular lens
    Marinho, A
    Neves, MC
    Pinto, MC
    Vaz, F
    JOURNAL OF REFRACTIVE SURGERY, 1997, 13 (03): : 219 - 222
  • [43] The STAAR posterior chamber phakic intraocular lens
    Zaldivar, R
    Oscherow, S
    Ricur, G
    INTERNATIONAL OPHTHALMOLOGY CLINICS, 2000, 40 (03) : 237 - 244
  • [44] The best choice for low and moderate myopia patients incapable for corneal refractive surgery: implantation of a posterior chamber phakic intraocular lens
    Qin Wang
    Lina Fan
    Qizhi Zhou
    International Ophthalmology, 2023, 43 : 575 - 581
  • [45] The best choice for low and moderate myopia patients incapable for corneal refractive surgery: implantation of a posterior chamber phakic intraocular lens
    Wang, Qin
    Fan, Lina
    Zhou, Qizhi
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (02) : 575 - 581
  • [46] Safety of posterior chamber phakic intraocular lenses for the correction of high myopia -: Anterior segment changes after posterior chamber phakic intraocular lens implantation
    Jiménez-Alfaro, I
    del Castillo, JMB
    García-Feijoó, J
    de Bernabé, JGG
    de la Iglesia, JMS
    OPHTHALMOLOGY, 2001, 108 (01) : 90 - 99
  • [47] Changes in anterior chamber volume after implantation of posterior chamber phakic intraocular lens in high myopia
    Zhu, Yi
    Zhu, Haobin
    Jia, Yan
    Zhou, Jibo
    BMC OPHTHALMOLOGY, 2018, 18
  • [48] Changes in anterior chamber volume after implantation of posterior chamber phakic intraocular lens in high myopia
    Yi Zhu
    Haobin Zhu
    Yan Jia
    Jibo Zhou
    BMC Ophthalmology, 18
  • [49] Rhegmatogenous retinal detachment in phakic eyes after posterior chamber phakic intraocular lens implantation for severe myopia
    Martínez-Castillo, V
    Boixadera, A
    Verdugo, A
    Elíes, D
    Coret, A
    García-Arumí, J
    OPHTHALMOLOGY, 2005, 112 (04) : 580 - 585
  • [50] Safety and clinical results of posterior chamber phakic intraocular lens implantation in low anterior chamber depth
    Lee, Min Gyu
    Lim, Dong Hui
    Chung, Eui Sang
    Chung, Tae-Young
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)