BACKGROUND: We investigated the efficacy, safety, and stability of correction achieved with a silicone posterior chamber intraocular lens used to correct high myopia in phakic eyes. PATIENTS AND METHODS: A silicone posterior chamber plate-style intraocular lens (Chiron, Adatomed) was implanted in 38 consecutive phakic eyes with high myopia (-7.00 to -28.00 diopters (D) over a period of 21 months. Follow-up ranged from 3 to 24 months. RESULTS: Three months after surgery, refractions in 27 eyes (71%) ranged from -1.00 to +1.00 D and remained stable thereafter. Spectacle-corrected visual acuity improved at least two lines in 24 eyes (63%), and none was lost in any eye. Patient satisfaction was high (92%). The few complications that occurred were mostly related to imperfections in the surgical technique rather than lack of biocompatibility of the lens. No cataract or other vision-threatening complication was present at the end of the study. CONCLUSION: This silicone posterior chamber plate-style intraocular lens provides a reasonably predictable, safe, and stable means of correcting high myopia.
引用
收藏
页码:219 / 222
页数:4
相关论文
共 50 条
  • [1] Ultrasound biomicroscopy of silicone posterior chamber phakic intraocular lens for myopia
    García-Feijoó, J
    Hernández-Matamoros, JL
    Méndez-Hernández, C
    Castillo-Gómez, A
    Lázaro, C
    Martín, T
    Cuiña-Sardiña, R
    García-Sánchez, J
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (10): : 1932 - 1939
  • [2] Silicone posterior chamber phakic intraocular lens dislocated into the vitreous cavity
    Martínez-Castillo, V
    Elies, D
    Boixadera, A
    García-Arumí, J
    Mauricio, J
    Cavero, L
    Coret, A
    JOURNAL OF REFRACTIVE SURGERY, 2004, 20 (06) : 773 - 777
  • [3] Posterior chamber phakic intraocular lens
    Trindade, F
    JOURNAL OF REFRACTIVE SURGERY, 2001, 17 (02) : 155 - 155
  • [4] Posterior chamber phakic intraocular lens for hyperopia
    Sanders, DR
    Martin, RG
    Brown, DC
    Shepherd, J
    Deitz, MR
    DeLuca, MC
    JOURNAL OF REFRACTIVE SURGERY, 1999, 15 (03) : 309 - 315
  • [5] The STAAR posterior chamber phakic intraocular lens
    Zaldivar, R
    Oscherow, S
    Ricur, G
    INTERNATIONAL OPHTHALMOLOGY CLINICS, 2000, 40 (03) : 237 - 244
  • [6] Phakic posterior chamber intraocular lens for high myopia
    Pineda-Fernández, A
    Jaramillo, J
    Vargas, J
    Jaramillo, M
    Jaramillo, J
    Galíndez, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (11): : 2277 - 2283
  • [7] Cataract following posterior chamber phakic intraocular lens
    El-Sheikh, HF
    Tabbara, KF
    JOURNAL OF REFRACTIVE SURGERY, 2003, 19 (01) : 72 - 73
  • [8] Phakic posterior chamber intraocular lens pupillary block
    Bylsma, SS
    Zalta, AH
    Foley, E
    Osher, RH
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (12): : 2222 - 2228
  • [9] High-frequency ultrasound biomicroscopy of silicone posterior chamber phakic intraocular lens for hyperopia
    García-Feijoó, J
    Hernández-Matamoros, JL
    Castillo-Gómez, A
    Lázaro, C
    Méndez-Hernández, C
    Martín, T
    de la Casa JMM
    García-Sánchez, J
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (10): : 1940 - 1946
  • [10] Lens opacities after posterior chamber phakic intraocular lens implantation
    Sánchez-Galeana, CA
    Smith, RJ
    Sanders, DR
    Rodríguez, FX
    Litwak, S
    Montes, M
    Chayet, AS
    OPHTHALMOLOGY, 2003, 110 (04) : 781 - 785