Effect of contact lens surface properties on comfort, tear stability and ocular physiology

被引:58
|
作者
Vidal-Rohr, Maria [1 ,2 ]
Wolffsohn, James S. [1 ]
Davies, Leon N. [1 ]
Cervino, Alejandro [2 ]
机构
[1] Aston Univ, Ophthalm Res Grp, Birmingham B4 7ET, W Midlands, England
[2] Univ Valencia, Dept Opt & Optometry & Vis Sci, Optometry Res Grp, E-46100 Burjassot, Spain
来源
CONTACT LENS & ANTERIOR EYE | 2018年 / 41卷 / 01期
基金
英国工程与自然科学研究理事会;
关键词
Discomfort; Coating; Soft contact lens; Tear film; Lubricity; Coefficient of friction; TFOS INTERNATIONAL WORKSHOP; DRY EYE DISEASE; CLINICAL-EVALUATION; DISCOMFORT REPORT; NORTH-AMERICA; WEARERS; FILM; SYMPTOMS; SUBCOMMITTEE;
D O I
10.1016/j.clae.2017.09.009
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: Retrospective analysis of different contact lens wearing groups suggests lens surface lubricity is the main factor influencing contact lens comfort. However, the examined commercially available contact lenses differ in material and design as well as surface properties. Hence this study isolates the contribution of lens surface properties using an ultra-thin coating technology. Methods: Nineteen habitual contact lens wearers (21.6 +/- 1.7 years) wore formofilcon B soft monthly disposable contact lenses with and without coating technology modified surface properties for a month each in a randomised double-masked cross-over study. Objective non-invasive: breakup time (NIKBUT), NIKBUT average and ocular redness (Jenvis grading scale) were evaluated (Keratograph 5M) after 1 week and 1 month of wear. Symptoms were assessed using the Contact Lens Dry Eye Questionnaire (CLDEQ-8); perceived vision quality and subjective lens comfort at insertion, mid-day and end of the day were rated with four Visual Analog Scales. Results: Perceived visual quality (F = 5.049, p = 0.037), contact lens dry eye symptoms (F = 14.408, p = 0.001) and subjective lens comfort (F = 28.447, p < 0.001) were better for coated compared to uncoated lenses. The surface coating postponed the lens dewetting (F = 8.518, p = 0.009) and increased the pre-lens tear film stability (F = 5.626, p = 0.029), but bulbar (F = 0.340, p = 0.567) and limbal (F = 0.110, p = 0.744) redness were similar for both contact lenses. No parameter changed significantly between a weeks' and months' wear (p > 0.05). Lens surface wettability and ocular redness were not correlated to changes in symptoms (p > 0.05). Conclusion: As previously hypothesised, enhancing the physical surface properties of a soft contact lens improves subjectively rated wearer comfort, which, in turn, should result in reduced contact lens discontinuation.
引用
收藏
页码:117 / 121
页数:5
相关论文
共 50 条
  • [41] Comparison of the impact of nesofilcon A hydrogel contact lens on the ocular surface and the comfort of presbyopic and non-presbyopic wearers
    Lorente-Velazquez, Amalia
    Garcia-Montero, Maria
    Javier Gomez-Sanz, Francisco
    Rico del Viejo, Laura
    Luis Hernandez-Verdejo, Jose
    Madrid-Costa, David
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2019, 12 (04) : 640 - 646
  • [42] Comparison of the impact of nesofilcon A hydrogel contact lens on the ocular surface and the comfort of presbyopic and non-presbyopic wearers
    Amalia Lorente-Velázquez
    María García-Montero
    Francisco Javier Gómez-Sanz
    Laura Rico del Viejo
    José Luis Hernández-Verdejo
    David Madrid-Costa
    International Journal of Ophthalmology, 2019, (04) : 640 - 646
  • [43] Effect of Eye Spray Phospholipid Concentration on the Tear Film and Ocular Comfort
    Pult, Heiko
    Khatum, Farzana S.
    Trave-Huarte, Sonia
    Wolffsohn, James S.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2021, 47 (08): : 445 - 448
  • [44] Effect of tear film stability on ocular surface damage in a population of dry eye patients
    Schindelar, M
    Ousler, GW
    Abelson, MB
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [45] Conjunctival Vascular Adaptation Related to Ocular Comfort in Habitual Contact Lens Wearers
    Chen, Qi
    Jiang, Hong
    Wang, Jianhua
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 216 : 99 - 109
  • [46] Ocular surface anatomy and physiology underlying scleral lens application
    Knop, E.
    Knop, N.
    ACTA OPHTHALMOLOGICA, 2014, 92
  • [47] Demographic Factors Affect Ocular Comfort Ratings During Contact Lens Wear
    Naduvilath, Thomas
    Papas, Eric B.
    de la Jara, Percy Lazon
    OPTOMETRY AND VISION SCIENCE, 2016, 93 (08) : 1004 - 1010
  • [48] Estimating a Just-Noticeable Difference for Ocular Comfort in Contact Lens Wearers
    Papas, Eric B.
    Keay, Lisa
    Golebiowski, Blanka
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (07) : 4390 - 4394
  • [49] Impact of contact lens material and design on the ocular surface
    Ruiz-Alcocer, Javier
    Monsalvez-Romin, Daniel
    Garcia-Lazaro, Santiago
    Albarran-Diego, Cesar
    Luis Hernandez-Verdejo, Jose
    Madrid-Costa, David
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2018, 101 (02) : 188 - 192
  • [50] Ocular surface changes induced by contact lens wear
    Pisella, PJ
    Malet, F
    Lejeune, S
    Brignole, F
    Debbasch, C
    Bara, J
    Rat, P
    Colin, J
    Baudouin, C
    CORNEA, 2001, 20 (08) : 820 - 825