Numerical analysis of the performance of a venturi-shaped roof for natural ventilation: Influence of building width

被引:21
|
作者
van Hooff, T. [1 ,2 ]
Blocken, B. [1 ]
Aanen, L. [3 ]
Bronsema, B. [4 ]
机构
[1] Eindhoven Univ Technol, NL-5600 MB Eindhoven, Netherlands
[2] Katholieke Univ Leuven, Dept Civil Engn, Div Bldg Phys, B-3001 Louvain, Belgium
[3] Peutz BV, NL-6585 ZH Mook, Netherlands
[4] Delft Univ Technol, Dept Climate Design, Fac Architecture, NL-2251 HX Voorschoten, Netherlands
关键词
Computational Fluid Dynamics (CFD); Building dimensions; Natural ventilation; Venturi-effect; Buildings; Airflow; ATMOSPHERIC BOUNDARY-LAYER; PERPENDICULAR BUILDINGS; COMPUTATIONAL ANALYSIS; FLUID-MECHANICS; CFD SIMULATION; WIND; PASSAGES; DRIVEN; FLOWS;
D O I
10.1016/j.jweia.2012.02.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A numerical analysis with Computational Fluid Dynamics (CFD) is performed to investigate the influence of building width on the performance of a venturi-shaped roof (called Ventec roof) for natural ventilation. The specific roof configuration is intended to create an underpressure in the narrowest roof section (contraction) which can be used to partly or completely drive the natural ventilation of the building zones. In previous studies, the influence of the roof configuration on its performance was analysed in detail, however these studies were all performed for a fixed building geometry, i.e. a tower building with floor plan 20 x 20 m(2) and a height of 50 m. It is important to analyse the performance of the Ventec roof for different building widths. Therefore, the present paper presents CFD simulations for building (and roof) widths of 20, 40, 80, 120 and 160 m. The 3D steady Reynolds-averaged Navier-Stokes (RANS) approach with the Renormalization Group (RNG) k-epsilon model is used. The simulations are based on grid-sensitivity analysis and on validation by comparison with wind tunnel experiments. The simulations show that the aerodynamic performance of the roof in terms of the underpressure in the contraction improves with 31% when the building width is increased from 20 m to 40 m, while further increasing the building width only provides relatively small additional improvements. The increased performance with increasing building width is attributed to the larger overpressure upstream of the building and to the larger underpressure and larger size (height) of the wake behind the building. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:419 / 427
页数:9
相关论文
共 50 条
  • [41] Analysis and calculation of enclosed coal yard ventilation by using roof vortex flow natural ventilation
    Cheng, Li
    Feng, Haibo
    Gu, Zhaoyang
    Yan, Dichun
    Guo, Hongbing
    Xu, Qian
    2019 5TH INTERNATIONAL CONFERENCE ON ENERGY MATERIALS AND ENVIRONMENT ENGINEERING, 2019, 295
  • [42] Numerical and Experimental Study of an Airing Device for Controlled Natural Ventilation of a Building
    Simonetti, Marco
    Fracastoro, Gian Vincenzo
    INTERNATIONAL JOURNAL OF VENTILATION, 2008, 7 (03) : 187 - 196
  • [43] Numerical and experimental study of an airing device for controlled natural ventilation of a building
    Department of Energetics, Polytechnic of Turin, Turin, Italy
    Int. J. Vent., 2008, 3 (187-196):
  • [44] Monitoring point of external wind velocity around building roof top for natural ventilation control
    Hajime A.
    Tomohiro K.
    Toshio Y.
    Kana S.
    Journal of Environmental Engineering (Japan), 2021, 86 (783): : 537 - 547
  • [45] 3D EXPERIMENTAL AND NUMERICAL ANALYSIS OF NATURAL VENTILATION OF DOMED-ROOF BUILDINGS DURING ECONOMIZER MODE
    Rahmatmand, A.
    Yaghoubi, M.
    Rad, E. Goshtasbi
    PROCEEDINGS OF THE ASME 6TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY - 2012, PTS A AND B, 2012, : 39 - 47
  • [46] Numerical investigation of coupled surface radiation and natural convection in a triangular shaped roof (gabel roof) under winter conditions
    Amrani A.-I.
    Dihmani N.
    Amraqui S.
    Mezrhab A.
    Defect and Diffusion Forum, 2019, 392 : 200 - 217
  • [47] Simulated performance of natural and hybrid ventilation systems in an office building
    Emmerich, Steven J.
    HVAC&R RESEARCH, 2006, 12 (04): : 975 - 1004
  • [48] Numerical investigation and optimization for performance analysis in Venturi inlet cyclone separator
    Venkatesh, S.
    Sakthivel, M.
    DESALINATION AND WATER TREATMENT, 2017, 90 : 168 - 179
  • [49] Effectiveness of enhanced roof ventilation unit (ERU) based on venturi cap in different wind environments and new evaluation models: A numerical study
    Tian, Lei
    Yao, Wanxiang
    Liu, Zu-An
    Shen, Qiong
    Zhang, Lili
    Fei, Fan
    Xia, Yueqiu
    Fukuda, Hiroatsu
    JOURNAL OF BUILDING ENGINEERING, 2024, 87
  • [50] Numerical simulations of full-scale enclosure fires in a small compartment with natural roof ventilation
    Merci, Bart
    Van Maele, Karim
    FIRE SAFETY JOURNAL, 2008, 43 (07) : 495 - 511