Effectiveness of enhanced roof ventilation unit (ERU) based on venturi cap in different wind environments and new evaluation models: A numerical study

被引:0
|
作者
Tian, Lei [1 ,2 ]
Yao, Wanxiang [1 ,2 ,3 ]
Liu, Zu-An [1 ,2 ]
Shen, Qiong [4 ]
Zhang, Lili [4 ]
Fei, Fan [2 ]
Xia, Yueqiu [2 ]
Fukuda, Hiroatsu [2 ]
机构
[1] Xuzhou Univ Technol, Sch Civil Engn, Xuzhou 221018, Peoples R China
[2] Univ Kitakyushu, Fac Environm Engn, Kitakyushu 8080135, Japan
[3] Qingdao Univ Technol, ISMART, Qingdao 266033, Peoples R China
[4] Sichuan Agr Univ, Coll Architectural & Urban Rural Planning, Dujiangyan 611830, Peoples R China
来源
关键词
Venturi cap; Wind environment; Enhanced roof ventilation unit; Evaluation model; Climate adaptability; NATURAL VENTILATION; THERMAL PERFORMANCE; ENERGY-CONSUMPTION; CROSS-VENTILATION; CFD SIMULATION; SHAPED ROOF; AIR-FLOW; EFFICIENCY; BUILDINGS; IMPACT;
D O I
10.1016/j.jobe.2024.109135
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Reasonable building ventilation design can effectively improve indoor thermal comfort and reduce energy consumption. Therefore, an enhanced roof ventilation unit (ERU) was developed for this study, and its performance and influence law under various wind speeds and directions were explored through numerical simulation. Additionally, a new evaluation method for ERU was proposed through data fitting, and applicability was verified for different climate zones in China. The results showed that: (1) With a maximum difference of 3.11 degrees C, the ERU performed best in the N direction and poorest in the SW direction for indoor temperature. Furthermore, the impact of wind directions was more evident than wind speeds. (2) The wind speed affected the volume flow rate significantly in the NE direction (7.77 m3/s) and insignificantly not in the SE direction (0.32 m3/s). Nevertheless, the performance was the opposite in the NE and SE directions when the wind speed increased from 0.5 m/s (3) The air age performed best in the NE and worst in the SE directions. As wind speeds surpassed 2.0 m/s, the air age variation steadily stabilized in various wind directions. (4) The fitted equation for indoor temperature has applicability in typical cities in five climate zones, and the fitted equation for volume flow rate is applicable in four climate zones except the hot summer and warm winter zone. The study results can provide references for the ERU to improve indoor thermal ventilation, contributing to sustainable building energy efficiency.
引用
收藏
页数:17
相关论文
共 4 条
  • [1] Influence and optimization of building opening configurations on the performance of enhanced roof ventilation units (ERU): a numerical and orthogonal study
    Tian, Lei
    Liu, Zu-An
    Li, You
    Hou, Jiawen
    Xiao, Yuling
    Fei, Fan
    Xia, Yueqiu
    Yao, Wanxiang
    Fukuda, Hiroatsu
    CASE STUDIES IN THERMAL ENGINEERING, 2025, 66
  • [2] Wind Tunnel Study on the Pressure Coefficient Performance of Different Venturi Shaped Roof Configurations for Wind Induced Natural Ventilation
    Boroojerdian, M. M.
    Adam, N. M.
    Rafie, A. S. M.
    ADVANCES IN MECHANICAL AND MANUFACTURING ENGINEERING, 2014, 564 : 287 - 291
  • [3] A venturi-shaped roof for wind-induced natural ventilation of buildings: Wind tunnel and CFD evaluation of different design configurations
    van Hooff, T.
    Blocken, B.
    Aanen, L.
    Bronsema, B.
    BUILDING AND ENVIRONMENT, 2011, 46 (09) : 1797 - 1807
  • [4] EVALUATION OF DIFFERENT SUNSHINE-BASED MODELS FOR PREDICTING GLOBAL SOLAR RADIATION - Case Study: New Borg El-Arab City, Egypt
    Hassan, Gasser E.
    Youssef, M. Elsayed
    Ali, Mohamed A.
    Mohamed, Zahraa E.
    Hanafy, Ahmed A.
    THERMAL SCIENCE, 2018, 22 (02): : 979 - 992