Numerical analysis of the performance of a venturi-shaped roof for natural ventilation: Influence of building width

被引:21
|
作者
van Hooff, T. [1 ,2 ]
Blocken, B. [1 ]
Aanen, L. [3 ]
Bronsema, B. [4 ]
机构
[1] Eindhoven Univ Technol, NL-5600 MB Eindhoven, Netherlands
[2] Katholieke Univ Leuven, Dept Civil Engn, Div Bldg Phys, B-3001 Louvain, Belgium
[3] Peutz BV, NL-6585 ZH Mook, Netherlands
[4] Delft Univ Technol, Dept Climate Design, Fac Architecture, NL-2251 HX Voorschoten, Netherlands
关键词
Computational Fluid Dynamics (CFD); Building dimensions; Natural ventilation; Venturi-effect; Buildings; Airflow; ATMOSPHERIC BOUNDARY-LAYER; PERPENDICULAR BUILDINGS; COMPUTATIONAL ANALYSIS; FLUID-MECHANICS; CFD SIMULATION; WIND; PASSAGES; DRIVEN; FLOWS;
D O I
10.1016/j.jweia.2012.02.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A numerical analysis with Computational Fluid Dynamics (CFD) is performed to investigate the influence of building width on the performance of a venturi-shaped roof (called Ventec roof) for natural ventilation. The specific roof configuration is intended to create an underpressure in the narrowest roof section (contraction) which can be used to partly or completely drive the natural ventilation of the building zones. In previous studies, the influence of the roof configuration on its performance was analysed in detail, however these studies were all performed for a fixed building geometry, i.e. a tower building with floor plan 20 x 20 m(2) and a height of 50 m. It is important to analyse the performance of the Ventec roof for different building widths. Therefore, the present paper presents CFD simulations for building (and roof) widths of 20, 40, 80, 120 and 160 m. The 3D steady Reynolds-averaged Navier-Stokes (RANS) approach with the Renormalization Group (RNG) k-epsilon model is used. The simulations are based on grid-sensitivity analysis and on validation by comparison with wind tunnel experiments. The simulations show that the aerodynamic performance of the roof in terms of the underpressure in the contraction improves with 31% when the building width is increased from 20 m to 40 m, while further increasing the building width only provides relatively small additional improvements. The increased performance with increasing building width is attributed to the larger overpressure upstream of the building and to the larger underpressure and larger size (height) of the wake behind the building. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:419 / 427
页数:9
相关论文
共 50 条
  • [31] Numerical simulation of the impact of water body on building natural ventilation
    Li, Kong-Qing
    Gong, Guang-Cai
    Zou, Sheng-Hua
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2009, 36 (SUPPL. 2): : 119 - 123
  • [32] Numerical Investigation of Cross Ventilation Flow in A Gable Roof Building with Asymmetric Opening Positions
    Deka, Rupam
    Das, Kalyan Kumar
    Das, Dipankar
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2024, 16 (05): : 71 - 87
  • [33] NATURAL VENTILATION OF BUILDING USING CFD ANALYSIS
    Venkatesh, P. M.
    Kannan, M.
    Kumar, Bharath N.
    Rao, D. S. N. M.
    JOURNAL OF MECHANICS OF CONTINUA AND MATHEMATICAL SCIENCES, 2019, 14 (06): : 661 - 666
  • [34] ANALYSIS OF DOUBLE-SHELL ROOF VENTILATION IN A PREFABRICATED APARTMENT BUILDING
    Vojtus, Jaroslav
    Kovac, Martin
    GEOCONFERENCE ON NANO, BIO AND GREEN - TECHNOLOGIES FOR A SUSTAINABLE FUTURE, VOL II (SGEM 2014), 2014, : 33 - 40
  • [35] The Numerical Simulation For Wind Pressure On The Roof Of Rhombic Plane And Saddle-Shaped Building
    Wang, CaiHua
    Wu, JianFeng
    PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 869 - 872
  • [36] Experimental and numerical analysis of the influence of inlet configuration on the performance of a roof top solar chimney
    Al-Kayiem, Hussain H.
    Sreejaya, K. V.
    Chikere, Aja O.
    ENERGY AND BUILDINGS, 2018, 159 : 89 - 98
  • [37] EFFECT OF RIDGE OPENING WIDTH ON NATURAL VENTILATION PERFORMANCE DURING SUMMER
    CHOINIERE, Y
    MUNROE, JA
    CANADIAN AGRICULTURAL ENGINEERING, 1993, 35 (04): : 281 - 287
  • [38] Numerical Study of Natural Ventilation through a Roof Cavity for Reduction of Solar Heat gain
    Ababsa, D.
    Bougoul, S.
    TERRAGREEN 2012: CLEAN ENERGY SOLUTIONS FOR SUSTAINABLE ENVIRONMENT (CESSE), 2012, 18 : 974 - 982
  • [39] Ventilation performance analysis on low-rise courtyard building for various courtyard shape factors and roof topology
    Prakash, D.
    INTERNATIONAL JOURNAL OF VENTILATION, 2023, 22 (01) : 56 - 76
  • [40] STUDY ON THE INFLUENCE ON NATURAL VENTILATION CAUSED BY DIFFERENT BUILDING DENSITIES
    Xue, Fei
    Li, Xiaofeng
    Huang, He
    BUILDING SIMULATION 2013: 13TH INTERNATIONAL CONFERENCE OF THE INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2013, : 3322 - 3326