Ventilation performance analysis on low-rise courtyard building for various courtyard shape factors and roof topology

被引:6
|
作者
Prakash, D. [1 ]
机构
[1] SASTRA Deemed Univ, Sch Mech Engn, Thanjavur 612401, India
关键词
Courtyard building; low rise residential building; roof topology; airflow analysis; computational fluid dynamics; wind tunnel test; COMPUTATIONAL FLUID-DYNAMICS; WIND-TUNNEL EXPERIMENTS; LEEWARD SAWTOOTH ROOF; CROSS-VENTILATION; THERMAL PERFORMANCE; NATURAL VENTILATION; CFD SIMULATION; HOT; FLOW; COMFORT;
D O I
10.1080/14733315.2022.2036477
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Residential buildings in the street canyon are highly suffering from reduced natural ventilation since the surrounding buildings completely mask the window and door openings. For such buildings, ventilation through the roof is an excellent method, and the buildings with courtyard space are believed to provide good ventilation and comfort. However, proper designing of courtyard buildings is highly essential, and for that, a complete airflow study in and around the courtyard building is required. Hence, in this research work, a low-rise residential courtyard building is considered, and the influence of courtyard space shape factor and roof topology on the ventilation performance of courtyard buildings is studied. The airflow study is made with the aid of the computational fluid dynamics (CFD) technique. Grid sensitivity analysis, validation of CFD results with wind tunnel experiments, and repeatability error analysis on wind tunnel test rig are also conducted to ensure the reliability of CFD simulation results. From this analysis, the courtyard with a wider space entraps more air from the atmosphere, and the building with low height offers uniform airflow in the courtyard space. Roof topology significantly influences the airflow around the building. Among the analyzed roof shape, pitched roof shape seems to perform relatively better and enhance the indoor air velocity by 42% with reference to the building without courtyard space. Also, the thermal comfort index for the building with courtyard space is 1.16 whereas for a building without a courtyard is 2.42 on a 3 scale. The percentage dissatisfaction index (PPD) is 52.9% lesser in the building with courtyard space.
引用
收藏
页码:56 / 76
页数:21
相关论文
共 50 条
  • [1] Wind pressure characteristics of a low-rise building with various openings on a roof corner
    College of Civil Engineering, Hunan University, Changsha
    410082, China
    不详
    Wind Struct Int J, 1 (1-23):
  • [2] Wind pressure characteristics of a low-rise building with various openings on a roof corner
    Wang, Yunjie
    Li, Q. S.
    WIND AND STRUCTURES, 2015, 21 (01) : 1 - 23
  • [3] Analysis of the impact of a novel cool roof on cooling performance for a low-rise prefabricated building in China
    Ma, Mingquan
    Zhang, Kai
    Chen, Lufang
    Tang, Saihong
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2021, 42 (01): : 26 - 44
  • [4] LOCAL WIND LOADING ON THE ROOF OF A LOW-RISE BUILDING
    BIENKIEWICZ, B
    SUN, YW
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1992, 45 (01) : 11 - 24
  • [5] Analysis of wind load effect on the roof of low-rise building in the mountain Terrain
    Peng, Xingqian
    Shi, Linglin
    ADVANCED RESEARCH ON ADVANCED STRUCTURE, MATERIALS AND ENGINEERING, 2012, 382 : 176 - 182
  • [6] Analysis of Wind Load Effect on the Roof of Low-rise Building in the Mountain Terrain
    Peng Xingqian
    Shi Linglin
    Cui Limin
    Yang Rong
    ICTAS 2009: PROCEEDINGS OF SHANGHAI INTERNATIONAL CONFERENCE ON TECHNOLOGY OF ARCHITECTURE AND STRUCTURE, PT I, 2009, : 260 - 267
  • [7] Effects of green roof on the wind field of a low-rise building
    Wai, Wing-Hong Onyx
    Hu, Wen-Qing
    Li, Chi-Wai
    Zhan, Jie-Min
    FRONTIERS IN FLUID MECHANICS RESEARCH, 2015, 126 : 405 - 409
  • [8] Thermal Performance of a High-Rise Residential Building with Internal Courtyard in Tropical Climate
    Elgheriani, Lobna Hassan
    Bin Sudin, Parid Wardi
    Almhafdy, Abdulbasit Ali
    ENVIRONMENT-BEHAVIOUR PROCEEDINGS JOURNAL, 2018, 3 (07): : 357 - 366
  • [9] The effect of building shape modification on wind pressure differences for cross-ventilation of a low-rise building
    Yuan, Cheng See
    International Journal of Ventilation, 2007, 6 (02) : 167 - 176
  • [10] Net pressures on the roof of a low-rise building with wall openings
    Sharma, RN
    Richards, PJ
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2005, 93 (04) : 267 - 291