Comparison of Locking Versus Nonlocking Plates for Distal Fibula Fractures

被引:28
|
作者
Lyle, Shirley A. [1 ]
Malik, Catherine [1 ]
Oddy, Michael J. [1 ]
机构
[1] Univ Coll London Hosp, Dept Trauma & Orthopaed, 235 Euston Rd, London NW1 2BU, England
来源
JOURNAL OF FOOT & ANKLE SURGERY | 2018年 / 57卷 / 04期
关键词
ankle fracture; complications; cost; locking plate; trauma; ANKLE FRACTURES; OSTEOPOROTIC BONE; INTERNAL-FIXATION; EPIDEMIOLOGY; SURGERY;
D O I
10.1053/j.jfas.2017.11.035
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Locking plates might offer a biomechanical fixation advantage for distal fibula fractures with comminution or osteoporotic bone. In January 2011, our unit introduced a bone-specific locking plate for the distal fibula. The aim of the present study was to compare it against more conventional plating system implants for lateral malleolar fixation in terms of outcomes, crude costs, and complications. We retrospectively reviewed a consecutive cohort of patients with closed ankle fractures who presented within a 24-month period. The clinical and radiographic outcomes were compared among conventional plating using a one-third semitubular plate, a 3.5-mm limited-contact dynamic compression plate, and a 2.7-mm/3.5-mm locking compression distal fibula plate. A total of 145 patients with ankle fractures underwent surgical fixation: 87 (60.0%) with the semitubular plate, 22 (15.2%) with the limited-contact dynamic compression plate, and 36 (24.8%) with the locking compression distal fibula plate. A greater proportion of patients with established osteoporosis or osteoporosis risk factors were in the locking compression distal fibula plate group (27.8% versus 2.3% and 0%). Four patients (2.8%) required washout for infection. No significant differences were found between the sex distribution within the 3 groups (p = .432). No significant difference was found in the complication rate (p = .914) or the reoperation rate (p = .291) among the 3 groups. Although costing >6 times more than a standard fibula fixation construct (implant cost), bone-specific locking compression distal fibula plates add to the portfolio of implants available, especially for unstable fractures with poor bone quality. Crown Copyright (C) 2017. Published by Elsevier Inc. on behalf of the American College of Foot and Ankle Surgeons. All rights reserved.
引用
收藏
页码:664 / 667
页数:4
相关论文
共 50 条
  • [41] Comparison of Bite Force with Locking Plates versus Non-Locking Plates in the Treatment of Mandibular Fractures: A Meta-Analysis
    Ramos Gloria, Jose Cristiano
    Fernandes, Ighor Andrade
    da Silveira, Esmeralda Maria
    de Souza, Glaciele Maria
    Rocha, Ricardo Lopes
    Galvao, Endi Lanza
    Moreira Falci, Saulo Gabriel
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2018, 22 (02) : 181 - 189
  • [42] Locking plates in distal humerus fractures:study of 43 patients
    Rakesh Kumar Gupta
    Vinay Gupta
    Dickey Richard Marak
    中华创伤杂志(英文版), 2013, (04) : 207 - 211
  • [43] Outcome of distal end clavicle fractures treated with locking plates
    Raju Vaishya
    Vipul Vijay
    Vikram Khanna
    中华创伤杂志英文版, 2017, 20 (01) : 45 - 48
  • [44] Percutaneous Fixation of Distal Tibial Fractures Using Locking Plates
    Shanmugam, Chezhiyan
    Rahmatalla, Aziz
    Maffulli, Nicola
    TECHNIQUES IN ORTHOPAEDICS, 2007, 22 (03) : 162 - 166
  • [45] Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: A biomechanical study in cadavers
    Blythe, Murray
    Stoffel, Karl
    Jarrett, Paul
    Kuster, Markus
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (10): : 1587 - 1593
  • [46] Minimally Invasive Treatment of Distal Tibial Fractures with Locking and Non-Locking Plates
    Ozkaya, Ufuk
    Parmaksizoglu, Atilla S.
    Gul, Murat
    Sokucu, Sami
    Kabukcuoglu, Yavuz
    FOOT & ANKLE INTERNATIONAL, 2009, 30 (12) : 1161 - 1167
  • [47] Mono versus polyaxial locking plates in distal femur fractures: a prospective randomized multicentre clinical trial
    Yueju Liu
    Han Li
    Yingze Zhang
    International Orthopaedics, 2014, 38 : 1543 - 1543
  • [48] Volar locking plates versus Kirschner wires for distal radial fractures-A cost analysis study
    Shyamalan, Gunaratnam
    Theokli, Chris
    Pearse, Yemi
    Tennent, Duncan
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2009, 40 (12): : 1279 - 1281
  • [49] Mono versus polyaxial locking plates in distal femur fractures: a prospective randomized multicentre clinical trial
    Liu, Yueju
    Li, Han
    Zhang, Yingze
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (07) : 1543 - 1543
  • [50] Comparison of Treatment of Acute Unstable Distal Clavicle Fractures Using Anatomical Locking Plates with Versus without Additional Suture Anchor Fixation
    Fan, Jixing
    Zhang, Yufu
    Huang, Qiang
    Jiang, Xieyuan
    He, Liang
    MEDICAL SCIENCE MONITOR, 2017, 23 : 5455 - 5461