Locking plates might offer a biomechanical fixation advantage for distal fibula fractures with comminution or osteoporotic bone. In January 2011, our unit introduced a bone-specific locking plate for the distal fibula. The aim of the present study was to compare it against more conventional plating system implants for lateral malleolar fixation in terms of outcomes, crude costs, and complications. We retrospectively reviewed a consecutive cohort of patients with closed ankle fractures who presented within a 24-month period. The clinical and radiographic outcomes were compared among conventional plating using a one-third semitubular plate, a 3.5-mm limited-contact dynamic compression plate, and a 2.7-mm/3.5-mm locking compression distal fibula plate. A total of 145 patients with ankle fractures underwent surgical fixation: 87 (60.0%) with the semitubular plate, 22 (15.2%) with the limited-contact dynamic compression plate, and 36 (24.8%) with the locking compression distal fibula plate. A greater proportion of patients with established osteoporosis or osteoporosis risk factors were in the locking compression distal fibula plate group (27.8% versus 2.3% and 0%). Four patients (2.8%) required washout for infection. No significant differences were found between the sex distribution within the 3 groups (p = .432). No significant difference was found in the complication rate (p = .914) or the reoperation rate (p = .291) among the 3 groups. Although costing >6 times more than a standard fibula fixation construct (implant cost), bone-specific locking compression distal fibula plates add to the portfolio of implants available, especially for unstable fractures with poor bone quality. Crown Copyright (C) 2017. Published by Elsevier Inc. on behalf of the American College of Foot and Ankle Surgeons. All rights reserved.
引用
收藏
页码:664 / 667
页数:4
相关论文
共 50 条
  • [31] Biomechanical Testing of Locking and Nonlocking Plates in the Canine Scapula
    Acquaviva, Anthony E.
    Miller, Emily I.
    Eisenmann, David J.
    Stone, Rick T.
    Kraus, Karl H.
    JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 2012, 48 (06) : 372 - 378
  • [32] Comparative analysis of locking plates versus hook plates in the treatment of Neer type II distal clavicle fractures
    Wang, Hong-Kai
    Liang, Li-Sheng
    He, Ren-Gao
    Su, Yu-Bin
    Mao, Peng
    Hu, Jun-Zu
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (04)
  • [33] Implant Failure Rates and Cost Analysis of Contoured Locking Versus Conventional Plate Fixation of Distal Fibula Fractures
    Moss, Lewis K.
    Kim-Orden, Michael H.
    Ravinsky, Robert
    Hoshino, Christopher M.
    Zinar, Daniel M.
    Gold, Stuart M.
    ORTHOPEDICS, 2017, 40 (06) : E1024 - E1029
  • [34] Volar locking plates versus Kirschner wires for distal radial fractures - A cost analysis study
    Horriat, Saman
    Marsh, Alastair
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (02): : 229 - 229
  • [35] A retrospective comparison of double-hooked locking plates versus non-locking plates in minimally invasive percutaneous plate osteosynthesis for the treatment of comminuted distal fibular fractures accompanied by tibial Pilon fractures
    Liu, Jun-Hong
    Zhang, Qiang
    Wei, Guo-Hua
    Liu, Liang
    Mu, Xin
    Li, Mao-Lin
    Wu, Zong-De
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [36] A retrospective comparison of double-hooked locking plates versus non-locking plates in minimally invasive percutaneous plate osteosynthesis for the treatment of comminuted distal fibular fractures accompanied by tibial Pilon fractures
    Jun-Hong Liu
    Qiang Zhang
    Guo-Hua Wei
    Liang Liu
    Xin Mu
    Mao-Lin Li
    Zong-De Wu
    Journal of Orthopaedic Surgery and Research, 18
  • [37] Locking plates in distal humerus fractures: study of 43 patients
    Gupta, Rakesh Kumar
    Gupta, Vinay
    Marak, Dickey Richard
    CHINESE JOURNAL OF TRAUMATOLOGY, 2013, 16 (04) : 207 - 211
  • [38] Management of Mandibular Fractures Using Locking and Nonlocking Miniplates
    Wusiman, Patiguli
    Tayie, Alifu
    Ling, Wang
    Moming, Adili
    JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (02) : 448 - 452
  • [39] Locking Plates for Distal Femur Fractures: Is There a Problem With Fracture Healing?
    Henderson, Christopher E.
    Kuhl, Lori L.
    Fitzpatrick, Daniel C.
    Marsh, J. L.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 : S8 - S14
  • [40] Locking versus nonlocking plates in mandibular reconstruction with fibular graft—a biomechanical ex vivo study
    Susanne Trainotti
    Stefan Raith
    Marco Kesting
    Stefan Eichhorn
    Florian Bauer
    Andreas Kolk
    Bernd Lethaus
    Frank Hölzle
    Timm Steiner
    Clinical Oral Investigations, 2014, 18 : 1291 - 1298