Comparison of Locking Versus Nonlocking Plates for Distal Fibula Fractures

被引:28
|
作者
Lyle, Shirley A. [1 ]
Malik, Catherine [1 ]
Oddy, Michael J. [1 ]
机构
[1] Univ Coll London Hosp, Dept Trauma & Orthopaed, 235 Euston Rd, London NW1 2BU, England
来源
JOURNAL OF FOOT & ANKLE SURGERY | 2018年 / 57卷 / 04期
关键词
ankle fracture; complications; cost; locking plate; trauma; ANKLE FRACTURES; OSTEOPOROTIC BONE; INTERNAL-FIXATION; EPIDEMIOLOGY; SURGERY;
D O I
10.1053/j.jfas.2017.11.035
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Locking plates might offer a biomechanical fixation advantage for distal fibula fractures with comminution or osteoporotic bone. In January 2011, our unit introduced a bone-specific locking plate for the distal fibula. The aim of the present study was to compare it against more conventional plating system implants for lateral malleolar fixation in terms of outcomes, crude costs, and complications. We retrospectively reviewed a consecutive cohort of patients with closed ankle fractures who presented within a 24-month period. The clinical and radiographic outcomes were compared among conventional plating using a one-third semitubular plate, a 3.5-mm limited-contact dynamic compression plate, and a 2.7-mm/3.5-mm locking compression distal fibula plate. A total of 145 patients with ankle fractures underwent surgical fixation: 87 (60.0%) with the semitubular plate, 22 (15.2%) with the limited-contact dynamic compression plate, and 36 (24.8%) with the locking compression distal fibula plate. A greater proportion of patients with established osteoporosis or osteoporosis risk factors were in the locking compression distal fibula plate group (27.8% versus 2.3% and 0%). Four patients (2.8%) required washout for infection. No significant differences were found between the sex distribution within the 3 groups (p = .432). No significant difference was found in the complication rate (p = .914) or the reoperation rate (p = .291) among the 3 groups. Although costing >6 times more than a standard fibula fixation construct (implant cost), bone-specific locking compression distal fibula plates add to the portfolio of implants available, especially for unstable fractures with poor bone quality. Crown Copyright (C) 2017. Published by Elsevier Inc. on behalf of the American College of Foot and Ankle Surgeons. All rights reserved.
引用
收藏
页码:664 / 667
页数:4
相关论文
共 50 条
  • [21] A Comparison of Nonlocking Semitubular Plates and Precontoured Locking Plates for First Metatarsophalangeal Joint Arthrodesis
    Mayer, Stephanie A.
    Zelenski, Nicole A.
    DeOrio, James K.
    Easley, Mark E.
    Nunley, James A., II
    FOOT & ANKLE INTERNATIONAL, 2014, 35 (05) : 438 - 444
  • [22] Torsional Failure of Carbon Fiber Composite Plates Versus Stainless Steel Plates for Comminuted Distal Fibula Fractures
    Wilson, William K.
    Morris, Randal P.
    Ward, Adam J.
    Carayannopoulos, Nikoletta L.
    Panchbhavi, Vinod K.
    FOOT & ANKLE INTERNATIONAL, 2016, 37 (05) : 548 - 553
  • [23] Finite element simulation of treatment with locking plate for distal fibula fractures
    Li, Yafeng
    Zou, Zichun
    Yi, Peng
    Xu, Chen
    Tian, Zhifeng
    Zhang, Xi
    Zhang, Jing
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, : 1461 - 1468
  • [24] Does plate adaptation affect stability? A biomechanical comparison of locking and nonlocking plates
    Haug, RH
    Street, CC
    Goltz, M
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 60 (11) : 1319 - 1326
  • [25] Comparison between Carbon-Peek volar locking plates and titanium volar locking plates in the treatment of distal radius fractures
    Perugia, Dario
    Guzzini, Matteo
    Mazza, Daniele
    Iorio, Carlo
    Civitenga, Carolina
    Ferretti, Andrea
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 : S24 - S29
  • [26] Osteosynthesis of distal femoral fractures by locking compression plates
    Ehlinger, Matthieu
    Adam, Philippe
    Abane, Lamine
    Bonnomet, Francois
    Arlettaz, Yvan
    SWISS MEDICAL WEEKLY, 2011, 141 : 19S - 19S
  • [27] Treatment of distal radius fractures with locking plates: an update
    Loisel F.
    Kielwasser H.
    Faivre G.
    Rondot T.
    Rochet S.
    Adam A.
    Sergent P.
    Leclerc G.
    Obert L.
    Lepage D.
    European Journal of Orthopaedic Surgery & Traumatology, 2018, 28 (8) : 1537 - 1542
  • [28] Operative Fixation of Lateral Malleolus Fractures With Locking Plates vs Nonlocking Plates: A Systematic Review and Meta-analysis
    Hasami, Nesar Ahmad
    Smeeing, Diederik Pieter Johan
    ter Gunne, Albert Frederik Pull
    Edwards, Michael John Richard
    Nelen, Stijn Diederik
    FOOT & ANKLE INTERNATIONAL, 2022, 43 (02) : 280 - 290
  • [29] Are locking plates better than non-locking plates for treating distal tibial fractures?
    Bastias, Christian
    Henriquez, Hugo
    Pellegrini, Manuel
    Rammelt, Stefan
    Cuchacovich, Natalio
    Lagos, Leonardo
    Carcuro, Giovanni
    FOOT AND ANKLE SURGERY, 2014, 20 (02) : 115 - 119
  • [30] Randomized Comparison of Volar Locking Plates and Intramedullary Nails for Unstable Distal Radius Fractures
    Plate, Johannes F.
    Gaffney, Daniel L.
    Emory, Cynthia L.
    Mannava, Sandeep
    Smith, Beth P.
    Koman, L. Andrew
    Wiesler, Ethan R.
    Li, Zhongyu
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (06): : 1095 - 1101