How Inaccurate is Weight as a Metric for Patient Size? Comparing Patient Weight to Effective Diameter for Size-Specific Dose Estimation

被引:2
|
作者
Cook, Tessa S. [1 ]
Chadalavada, Seetharam C. [1 ]
Boonn, William W. [1 ]
机构
[1] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
来源
MEDICAL IMAGING 2013: ADVANCED PACS-BASED IMAGING INFORMATICS AND THERAPEUTIC APPLICATIONS | 2013年 / 8674卷
关键词
patient-specific dose monitoring; computed tomography; size-specific dose estimates; patient size metrics; CT;
D O I
10.1117/12.2006132
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
One of the biggest challenges in dose monitoring is customization of CT dose estimates to the patient. Patient size remains a highly significant variable. One metric that has previously been used for patient size is patient weight, though this is often criticized as inaccurate. In this work, we compare patients' weight to their effective diameters obtained from a CT scan of the chest or the abdomen. CT exams of the chest (N= 163) and abdomen/pelvis (N= 168) performed on adult patients in July 2012 were randomly selected for analysis. The effective diameter of the patient for each exam was determined using the central slice of the scan region for each exam using eXposure (TM) (Radimetrics, Inc., Toronto, Canada). In some cases, the same patient had both a chest and abdominopelvic CT, so effective diameters from both regions were analyzed. In this small sample size, there appears to be a linear relationship between patient weight and effective diameter when measured in the mid-chest and mid-abdomen of adult patients. However, for each weight, patient effective diameter can vary by 5 cm from the regression line in both the chest and the abdomen. A 5-cm difference corresponds to a difference of approximately 0.2 in the chest and 0.3 in the abdomen/pelvis for the correction factors recommended for size-specific dose estimation by the AAPM. This preliminary data suggests that weight-based CT protocoling may in fact be appropriate for some adults. However, more work is needed to identify those patients in whom weight-based protocoling is not appropriate.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Accuracy of patient dose estimation in cone beam computed tomography in breast irradiation by size-specific dose estimates with position correction
    Ueno, Hiroyuki
    Matsubara, Kosuke
    Bou, Sayuri
    Hizume, Masato
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (12):
  • [22] Introduction and Investigation of Effective Diameter Ratios as a New Patient Size Metric for Use in CT
    Lamoureux, R.
    Sinclair, L.
    Mench, A.
    Lipnharski, I.
    Carranza, C.
    Cormack, B.
    Bidari, S.
    Rill, L.
    Arreola, M.
    MEDICAL PHYSICS, 2015, 42 (06) : 3247 - 3248
  • [23] Size Specific Dose Estimation in Abdominal CT: Impact of Longitudinal Variations in Patient Size
    Leng, S.
    Shiung, M.
    Duan, X.
    Yu, L.
    Zhang, Y.
    McCollough, C.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [24] Variations in size-specific effective dose with patient stature and beam width for kV cone beam CT imaging in radiotherapy
    Martin, C. J.
    Abuhaimed, A.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (03)
  • [25] A Segmentation-based Automated Calculation of Patient Size and Size-specific Dose Estimates in Pediatric Computed Tomography Scans
    Abdulkadir, Muhammad Kabir
    Osman, Noor Diyana
    Achuthan, Anusha
    Nasirudin, Radin A.
    Ahmad, Muhammad Zabidi
    Zain, Noor Hasyima Mat
    Shuaib, Ibrahim Lutfi
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (03) : 456 - 463
  • [26] BODY SIZE-SPECIFIC EFFECTIVE DOSE CONVERSION COEFFICIENTS FOR CT SCANS
    Romanyukha, Anna
    Folio, Les
    Lamart, Stephanie
    Simon, Steven L.
    Lee, Choonsik
    RADIATION PROTECTION DOSIMETRY, 2016, 172 (04) : 428 - 437
  • [27] Local Diagnostic Reference Levels and Size-Specific Patient Dose in Computed Tomography at a Greek Hospital
    Stasinou, D.
    Zoiopoulou, V.
    Antonakos, J.
    Argentos, S.
    Efstathopoulos, E.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [28] The role of Size-Specific Dose Estimate (SSDE) in patient-specific organ dose and cancer risk estimation in paediatric chest and abdominopelvic CT examinations
    Caro Franck
    Charlot Vandevoorde
    Ingeborg Goethals
    Peter Smeets
    Eric Achten
    Koenraad Verstraete
    Hubert Thierens
    Klaus Bacher
    European Radiology, 2016, 26 : 2646 - 2655
  • [29] The role of Size-Specific Dose Estimate (SSDE) in patient-specific organ dose and cancer risk estimation in paediatric chest and abdominopelvic CT examinations
    Franck, Caro
    Vandevoorde, Charlot
    Goethals, Ingeborg
    Smeets, Peter
    Achten, Eric
    Verstraete, Koenraad
    Thierens, Hubert
    Bacher, Klaus
    EUROPEAN RADIOLOGY, 2016, 26 (08) : 2646 - 2655
  • [30] Evaluation of direct point dose estimation based on the distribution of the size-specific dose estimate
    Anam, Choirul
    Sutanto, Heri
    Amilia, Riska
    Marini, Rini
    Barokah, Sinta Nur
    Osman, Noor Diyana
    Dougherty, Geoff
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (04) : 1525 - 1535