How Inaccurate is Weight as a Metric for Patient Size? Comparing Patient Weight to Effective Diameter for Size-Specific Dose Estimation

被引:2
|
作者
Cook, Tessa S. [1 ]
Chadalavada, Seetharam C. [1 ]
Boonn, William W. [1 ]
机构
[1] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
来源
MEDICAL IMAGING 2013: ADVANCED PACS-BASED IMAGING INFORMATICS AND THERAPEUTIC APPLICATIONS | 2013年 / 8674卷
关键词
patient-specific dose monitoring; computed tomography; size-specific dose estimates; patient size metrics; CT;
D O I
10.1117/12.2006132
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
One of the biggest challenges in dose monitoring is customization of CT dose estimates to the patient. Patient size remains a highly significant variable. One metric that has previously been used for patient size is patient weight, though this is often criticized as inaccurate. In this work, we compare patients' weight to their effective diameters obtained from a CT scan of the chest or the abdomen. CT exams of the chest (N= 163) and abdomen/pelvis (N= 168) performed on adult patients in July 2012 were randomly selected for analysis. The effective diameter of the patient for each exam was determined using the central slice of the scan region for each exam using eXposure (TM) (Radimetrics, Inc., Toronto, Canada). In some cases, the same patient had both a chest and abdominopelvic CT, so effective diameters from both regions were analyzed. In this small sample size, there appears to be a linear relationship between patient weight and effective diameter when measured in the mid-chest and mid-abdomen of adult patients. However, for each weight, patient effective diameter can vary by 5 cm from the regression line in both the chest and the abdomen. A 5-cm difference corresponds to a difference of approximately 0.2 in the chest and 0.3 in the abdomen/pelvis for the correction factors recommended for size-specific dose estimation by the AAPM. This preliminary data suggests that weight-based CT protocoling may in fact be appropriate for some adults. However, more work is needed to identify those patients in whom weight-based protocoling is not appropriate.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] How to Appropriately Calculate Effective Dose for CT Using Either Size-Specific Dose Estimates or Dose-Length Product
    Brady, Samuel L.
    Mirro, Amy E.
    Moore, Bria M.
    Kaufman, Robert A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (05) : 953 - 958
  • [32] Variation of Size-Specific Dose Estimates Across Patient Sizes Under the Conditions of Automatic Exposure Control
    McMillan, K.
    Huang, A.
    Leng, S.
    McCollough, C.
    MEDICAL PHYSICS, 2016, 43 (06) : 3861 - 3861
  • [33] Evaluation of patients' Body Mass Index and weight as a simpler alternative method for calculating size-specific dose estimation in patients with lung computed tomography
    Azinkhah, I.
    Sadeghi, M.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2024, 22 (02): : 257 - 264
  • [34] PATIENT DOSE SURVEY BASED ON SIZE-SPECIFIC DOSE ESTIMATE AND ACCEPTABLE QUALITY DOSE IN CHEST AND ABDOMEN/PELVIS CT EXAMINATIONS
    Mehdipour, Ali
    Parsi, Masoumeh
    Khorram, Faezeh-Sadat
    RADIATION PROTECTION DOSIMETRY, 2019, 185 (02) : 176 - 182
  • [35] How accurate is size-specific dose estimate in pediatric body CT examinations?
    Karmazyn, Boaz
    Ai, Huisi
    Klahr, Paul
    Ouyang, Fangqian
    Jennings, S. Gregory
    PEDIATRIC RADIOLOGY, 2016, 46 (09) : 1234 - 1240
  • [36] SIZE AND WEIGHT UNDERDEVELOPMENT AND FOOD ALLERGY IN A PATIENT WITH ASTHMA
    SABBAH, A
    FOURRIER, E
    BLANDIN, G
    OUEST MEDICAL, 1977, 30 (08): : 483 - 486
  • [37] Introduction and evaluation of size-specific DLP for radiation dose estimation in CT examinations
    Dendo, Yutaka
    Abe, Keisuke
    Onodera, Shu
    Kayano, Shingo
    Ota, Hideki
    Takase, Kei
    JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (04)
  • [38] How accurate is size-specific dose estimate in pediatric body CT examinations?
    Boaz Karmazyn
    Huisi Ai
    Paul Klahr
    Fangqian Ouyang
    S. Gregory Jennings
    Pediatric Radiology, 2016, 46 : 1234 - 1240
  • [39] Multivariate Analysis of Effective Dose and Size-Specific Dose Estimates for Thorax and Abdominal Computed Tomography
    Shah, Mudasir Ashraf
    Ahmad, Mehtab
    Khalid, Saifullah
    Qaseem, Syed M. Danish
    Siddiqui, Shaista
    Talib, Sayema
    Rather, Sajad Ahmed
    Firdous, Arfat
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (02) : 210 - 218
  • [40] Feasibility of Using Size-Specific Dose Estimate (SSDE) to Estimate Effective Dose of Individual Patients
    Abuhaimed, A.
    Martin, C.
    Lee, C.
    MEDICAL PHYSICS, 2021, 48 (06)