Variations in size-specific effective dose with patient stature and beam width for kV cone beam CT imaging in radiotherapy

被引:4
|
作者
Martin, C. J. [1 ]
Abuhaimed, A. [2 ]
机构
[1] Univ Glasgow, Gartnavel Royal Hosp, Dept Clin Phys & Bioengn, Glasgow G12 0XH, Lanark, Scotland
[2] King Abdulaziz City Sci & Technol KACST, Riyadh, Saudi Arabia
基金
美国国家卫生研究院;
关键词
cone beam CT (CBCT); radiotherapy; image guided radiation therapy (IGRT); image optimisation; size specific effective dose; patient dosimetry; Monte Carlo simulations; MONTE-CARLO; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; HYBRID PHANTOMS; CBCT SCANS; CANCER; THERAPY; ORGAN; IMRT; CHILDREN;
D O I
10.1088/1361-6498/ac85fa
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The facilities now available on linear accelerators for external beam radiotherapy enable radiation fields to be conformed to the shapes of tumours with a high level of precision. However, in order for the treatment delivered to take advantage of this, the patient must be positioned on the couch with the same degree of accuracy. Kilovoltage cone beam computed tomography systems are now incorporated into radiotherapy linear accelerators to allow imaging to be performed at the time of treatment, and image-guided radiation therapy is now standard in most radiotherapy departments throughout the world. However, because doses from imaging are much lower than therapy doses, less effort has been put into optimising radiological protection of imaging protocols. Standard imaging protocols supplied by the equipment vendor are often used with little adaptation to the stature of individual patients, and exposure factors and field sizes are frequently larger than necessary. In this study, the impact of using standard protocols for imaging anatomical phantoms of varying size from a library of 193 adult phantoms has been evaluated. Monte Carlo simulations were used to calculate doses for organs and tissues for each phantom, and results combined in terms of size-specific effective dose (SED). Values of SED from pelvic scans ranged from 11 mSv to 22 mSv for male phantoms and 8 mSv to 18 mSv for female phantoms, and for chest scans from 3.8 mSv to 7.6 mSv for male phantoms and 4.6 mSv to 9.5 mSv for female phantoms. Analysis of the results showed that if the same exposure parameters and field sizes are used, a person who is 5 cm shorter will receive a size SED that is 3%-10% greater, while a person who is 10 kg lighter will receive a dose that is 10%-14% greater compared with the average size.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Influence of beam width of cone beam CT (CBCT) scan on effective dose
    Abuhaimed, A.
    Martin, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1538 - S1539
  • [2] Patient dose in KV cone-beam CT image-guided radiotherapy
    Islam, M
    Purdie, T
    Moseley, D
    Alasti, H
    Norrlinger, B
    Sharpe, M
    Siewerdsen, J
    Jaffray, D
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1830 - 1830
  • [3] Size-specific dose estimates (SSDE) for a prototype orthopeadic cone-beam CT system
    Richard, Samuel
    Packard, Nathan
    Yorkston, John
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [4] Determination of size-specific exposure settings in dental cone-beam CT
    Ruben Pauwels
    Reinhilde Jacobs
    Ria Bogaerts
    Hilde Bosmans
    Soontra Panmekiate
    [J]. European Radiology, 2017, 27 : 279 - 285
  • [5] Determination of size-specific exposure settings in dental cone-beam CT
    Pauwels, Ruben
    Jacobs, Reinhilde
    Bogaerts, Ria
    Bosmans, Hilde
    Panmekiate, Soontra
    [J]. EUROPEAN RADIOLOGY, 2017, 27 (01) : 279 - 285
  • [6] Variation of size-specific dose estimates (SSDE) of cone-beam CT (CBCT) scans with the scan length
    Abuhaimed, A.
    Martin, C.
    Demirkaya, O.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S907 - S907
  • [7] Patient specific organ dose evaluation in cone beam CT
    Sardo, A.
    Giglioli, F. R.
    Gallio, E.
    Rossetti, V.
    Fiandra, C.
    Rampado, O.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S487 - S487
  • [8] Accuracy of patient dose estimation in cone beam computed tomography in breast irradiation by size-specific dose estimates with position correction
    Ueno, Hiroyuki
    Matsubara, Kosuke
    Bou, Sayuri
    Hizume, Masato
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (12):
  • [9] Raystation KV cone-beam CT radiotherapy dose calculation: toward clinical dose tracking
    Snir, Jonatan
    Murrell, Donna
    Fakir, Hatim
    [J]. MEDICAL PHYSICS, 2017, 44 (08) : 4380 - 4380
  • [10] A size-specific effective dose for patients undergoing CT examinations
    Anam, C.
    Haryanto, F.
    Widita, R.
    Arif, I.
    Fujibuchi, T.
    Dougherty, G.
    [J]. 7TH ASIAN PHYSICS SYMPOSIUM, 2019, 1204