Study of silicon detectors for high resolution radioxenon measurements

被引:10
|
作者
Hennig, Wolfgang [1 ]
Cox, Christopher E. [1 ]
Asztalos, Stephen J. [1 ]
Tan, Hui [1 ]
Franz, Patrick J. [1 ]
Grudberg, Peter M. [1 ]
Warburton, William K. [1 ]
Huber, Alan [2 ]
机构
[1] XIA LLC, Hayward, CA USA
[2] Amptek Inc, Bedford, MA 01730 USA
关键词
Silicon detector; Radioxenon; Beta/X-ray coincidence; Minimum detectable concentration;
D O I
10.1007/s10967-012-2053-y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Measurement of radioactive xenon in the atmosphere is one of several techniques to detect nuclear weapons testing, typically using either scintillator based coincidence beta/gamma detectors or germanium based gamma only detectors. Silicon detectors have a number of potential advantages over these detectors (high resolution, low background, sensitive to photons and electrons) and are explored in this work as a possible alternative. Using energy resolutions from measurements and detection efficiencies from simulations of characteristic electron and photon energies, the minimum detectable concentration for Xe isotopes was estimated for several possible detector geometries. Test coincidence spectra were acquired with a prototype detector.
引用
收藏
页码:675 / 681
页数:7
相关论文
共 50 条
  • [41] SILICON CARBIDE MICROSTRIP DETECTORS FOR HIGH RESOLUTION X-RAY SPECTROSCOPY
    Bertuccio, Giuseppe
    Puglisi, Donatella
    Lanzieri, Claudio
    ASTROPARTICLE, PARTICLE, SPACE PHYSICS AND DETECTORS FOR PHYSICS APPLICATIONS, 2012, 7 : 653 - 657
  • [42] A high resolution beam telescope built with double sided silicon strip detectors
    Celano, L
    Creanza, D
    dePalma, M
    Maggi, G
    Fiore, L
    Paticchio, V
    Raso, G
    Selvaggi, G
    Silvestris, L
    Tempesta, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 381 (01): : 49 - 56
  • [43] Non-destructive repetitive readout in high resolution silicon detectors.
    Castoldi, A
    Gatti, E
    Geraci, A
    Guazzoni, C
    Longoni, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) : 1346 - 1352
  • [44] HIGH-RESOLUTION PERFORMANCE OF SILICON DETECTORS OF SHORT-RANGE PARTICLES
    VERBITSKAYA, EM
    EREMIN, VK
    MALYARENKO, AM
    STROKAN, NB
    SUKHANOV, VL
    PISMA V ZHURNAL TEKHNICHESKOI FIZIKI, 1986, 12 (20): : 1254 - 1258
  • [45] A FAST HIGH-RESOLUTION BEAM HODOSCOPE USING SILICON MICROSTRIP DETECTORS
    HEIJNE, E
    JARRON, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (01) : 405 - 409
  • [46] SILICON RADIATION DETECTORS FOR HIGH-RESOLUTION X-RAY SPECTROSCOPY
    PIGNATEL, GU
    INFORMACIJE MIDEM-JOURNAL OF MICROELECTRONICS ELECTRONIC COMPONENTS AND MATERIALS, 1995, 25 (02): : 89 - 97
  • [47] High-speed high-resolution signal processing for multicell silicon drift detectors
    Hansen, K
    Reinecke, M
    Klär, H
    Benca, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (02) : 541 - 547
  • [48] Energy resolution of silicon charged particle detectors
    Artemov S.V.
    Radyuk G.A.
    Karakhodzhaev A.A.
    Abdullaeva Y.S.
    Yakushev V.P.
    Bulletin of the Russian Academy of Sciences: Physics, 2011, 75 (7) : 1015 - 1017
  • [49] Limitations on energy resolution of segmented silicon detectors
    Wiacek, P.
    Chudyba, M.
    Fiutowski, T.
    Dabrowski, W.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [50] SPATIAL-RESOLUTION OF SILICON MICROSTRIP DETECTORS
    TURCHETTA, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 335 (1-2): : 44 - 58