SPATIAL-RESOLUTION OF SILICON MICROSTRIP DETECTORS

被引:94
|
作者
TURCHETTA, R
机构
[1] LEPSI, ULP / CNRS, Strasbourg
关键词
D O I
10.1016/0168-9002(93)90255-G
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The spatial resolution of silicon microstrip detectors is studied as a function of the main detector parameters and of the track angle. Several algorithms for finding the position of particle hits are presented and analysed. Analytic expressions of the spatial resolution are derived for the main algorithms. Using a Monte Carlo simulation, the spatial resolution is calculated for each algorithm and, for each detector design and track geometry, the algorithm that gives the best resolution is determined.
引用
收藏
页码:44 / 58
页数:15
相关论文
共 50 条
  • [1] SPATIAL-RESOLUTION OF WEDGE-SHAPED SILICON MICROSTRIP DETECTORS
    ANTICIC, T
    BARNETT, B
    BLUMENFELD, B
    CHIEN, CY
    FISHER, P
    GOUGAS, A
    KRIZMANIC, J
    MADANSKY, L
    NEWMAN, D
    ORNDORFF, J
    PEVSNER, A
    SPANGLER, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 365 (01): : 70 - 75
  • [2] Spatial resolution of silicon microstrip detectors
    Turchetta, R.
    [J]. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993, A335 (1-2) : 44 - 58
  • [3] ONE MICRON SPATIAL-RESOLUTION WITH SILICON STRIP DETECTORS
    STRAVER, J
    TOKER, O
    WEILHAMMER, P
    COLLEDANI, C
    DULINSKI, W
    TURCHETTA, R
    BOSISIO, L
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 485 - 490
  • [4] A STUDY OF THE CHARGE CLUSTER CHARACTERISTICS AND SPATIAL-RESOLUTION OF A SILICON MICROSTRIP DETECTOR
    CHANG, YH
    CHEN, AE
    HOU, SR
    LIN, WT
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 363 (03): : 538 - 544
  • [5] SPATIAL-RESOLUTION OF SILICON MICROSTRIP DETECTOR FOR PARTICLES WITH LARGE INCIDENT ANGLE
    HANAI, H
    HABA, J
    HIGASHI, N
    IKEDA, H
    KOIKE, S
    MATSUDA, T
    OZAKI, H
    TANAKA, M
    TSUBOYAMA, T
    NAKAMURA, M
    SAITO, K
    OKUNO, S
    KISHIDA, T
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 314 (03): : 455 - 460
  • [6] OPTIMIZATION OF SPATIAL-RESOLUTION IN SPRITE DETECTORS
    ASHLEY, T
    ELLIOTT, CT
    WHITE, AM
    WOTHERSPOON, JTM
    JOHNS, MD
    [J]. INFRARED PHYSICS, 1984, 24 (01): : 25 - 33
  • [7] STUDY OF SPATIAL-RESOLUTION AND EFFICIENCY OF SILICON STRIP DETECTORS WITH DIFFERENT READOUT SCHEMES
    DABROWSKI, W
    GRYBOS, P
    IDZIK, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 356 (2-3): : 241 - 254
  • [8] Silicon microstrip detectors for digital mammography - evaluation and spatial resolution study
    Mali, T
    Cindro, V
    Mikuz, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 460 (01): : 76 - 80
  • [9] HIGH SPATIAL-RESOLUTION PARTICLE PHYSICS DETECTORS
    EISLER, FR
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1979, 163 (01): : 105 - 111
  • [10] HIGH SPATIAL-RESOLUTION PARTICLE PHYSICS DETECTORS
    EISLER, FR