A Method to Estimate the Accuracy of Radial Flow-Based Permeability Measuring Devices

被引:14
|
作者
Tan, Hua [1 ]
Pillai, Krishna M. [1 ]
机构
[1] Univ Wisconsin, Dept Mech Engn, Milwaukee, WI 53201 USA
基金
美国国家科学基金会;
关键词
liquid composite molding; LCM; RTM; VARTM; preform; unsaturated flow; permeability; permeability measurement; porous medium; INPLANE PERMEABILITY; UNSATURATED FLOW; FIBER PREFORMS;
D O I
10.1177/0021998308102464
中图分类号
TB33 [复合材料];
学科分类号
摘要
Radial flow experiment is often used to measure the permeability of fibrous porous media by the composites processing community. However, very little work has been done to calibrate the radial flow set-up with media of known permeability. This article presents a new method for calibrating the permeability measuring set-ups based on radial flows. A reference medium in the form of two concentric annular slits is created for the radial flow mold whose permeability is estimated analytically and numerically. It is observed that the experimentally measured permeability deviates from the theoretical and numerical permeabilities with an increase in the flow rate for an injection setup using a gear pump as well as a piston-cylinder pump. The deviation can be attributed to two possible reasons: one is the leakage between the calibration device and mold plate surfaces because of a slight mold deformation at higher flow rates, the other one is the increase in the gap clearance of the reference medium because of the higher gap pressures at higher flow rates. No such deviation is observed while measuring the permeability of a fiber mat at different flow rates. Hence, the proposed reference medium can calibrate a conventional radial flow-based permeability measuring setups at low flow rates; the accuracy thus obtained can be extended to higher flow rates as well if permeability of a fiber mat can be shown to remain constant with the flow rate.
引用
收藏
页码:2307 / 2332
页数:26
相关论文
共 50 条
  • [1] A Method to Estimate the Accuracy of Radial Flow-Based Permeability Measuring Devices (vol 43, pg 2307, 2009)
    Tan, Hua
    Pillai, Krishna M.
    JOURNAL OF COMPOSITE MATERIALS, 2009, 43 (26) : 3328 - 3328
  • [2] A method to estimate the accuracy of 1-D flow based permeability measuring devices
    Roy, Tonmoy
    Tan, Hua
    Pillai, Krishna M.
    JOURNAL OF COMPOSITE MATERIALS, 2007, 41 (17) : 2037 - 2055
  • [3] Flow-Based Optimization of Products or Devices
    Basse, Nils T.
    FLUIDS, 2020, 5 (02)
  • [4] A flow-based platform for measuring the acidity parameters in wine
    Vidigal, Susana S. M. P.
    Rangel, Antonio O. S. S.
    TALANTA, 2017, 168 : 313 - 319
  • [5] Investigation of bacterial chemotaxis in flow-based microfluidic devices
    Derek L Englert
    Michael D Manson
    Arul Jayaraman
    Nature Protocols, 2010, 5 : 864 - 872
  • [6] Investigation of bacterial chemotaxis in flow-based microfluidic devices
    Englert, Derek L.
    Manson, Michael D.
    Jayaraman, Arul
    NATURE PROTOCOLS, 2010, 5 (05) : 864 - 872
  • [7] Accuracy of portable devices in measuring peak cough flow
    Kulnik, Stefan Tino
    MacBean, Victoria
    Birring, Surinder Singh
    Moxham, John
    Rafferty, Gerrard Francis
    Kalra, Lalit
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (02) : 243 - 257
  • [8] Analysis of radial distribution systems with embedded series FACTS devices using a fast line flow-based algorithm
    Yan, P
    Sekar, A
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (04) : 1775 - 1782
  • [9] Flow-based relaxation method for edge detection
    Yoon, KC
    Park, KH
    ELECTRONICS LETTERS, 1996, 32 (01) : 28 - 29
  • [10] A Description of the flow-based capacity allocation method
    Kladnik, Blaž
    Artač, Gašper
    Štokelj, Tomaž
    Gubina, Andrej
    Elektrotehniski Vestnik/Electrotechnical Review, 2010, 77 (05): : 305 - 312