A Method to Estimate the Accuracy of Radial Flow-Based Permeability Measuring Devices

被引:14
|
作者
Tan, Hua [1 ]
Pillai, Krishna M. [1 ]
机构
[1] Univ Wisconsin, Dept Mech Engn, Milwaukee, WI 53201 USA
基金
美国国家科学基金会;
关键词
liquid composite molding; LCM; RTM; VARTM; preform; unsaturated flow; permeability; permeability measurement; porous medium; INPLANE PERMEABILITY; UNSATURATED FLOW; FIBER PREFORMS;
D O I
10.1177/0021998308102464
中图分类号
TB33 [复合材料];
学科分类号
摘要
Radial flow experiment is often used to measure the permeability of fibrous porous media by the composites processing community. However, very little work has been done to calibrate the radial flow set-up with media of known permeability. This article presents a new method for calibrating the permeability measuring set-ups based on radial flows. A reference medium in the form of two concentric annular slits is created for the radial flow mold whose permeability is estimated analytically and numerically. It is observed that the experimentally measured permeability deviates from the theoretical and numerical permeabilities with an increase in the flow rate for an injection setup using a gear pump as well as a piston-cylinder pump. The deviation can be attributed to two possible reasons: one is the leakage between the calibration device and mold plate surfaces because of a slight mold deformation at higher flow rates, the other one is the increase in the gap clearance of the reference medium because of the higher gap pressures at higher flow rates. No such deviation is observed while measuring the permeability of a fiber mat at different flow rates. Hence, the proposed reference medium can calibrate a conventional radial flow-based permeability measuring setups at low flow rates; the accuracy thus obtained can be extended to higher flow rates as well if permeability of a fiber mat can be shown to remain constant with the flow rate.
引用
收藏
页码:2307 / 2332
页数:26
相关论文
共 50 条
  • [41] Planar Odometry from a Radial Laser Scanner. A Range Flow-based Approach
    Jaimez, Mariano
    Monroy, Javier G.
    Gonzalez-Jimenez, Javier
    2016 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2016, : 4479 - 4485
  • [42] Application of the front tracking method in micro flow measuring devices
    Batista E.
    Sousa J.A.
    Álvares M.
    Afonso J.
    Martins R.F.
    Measurement: Sensors, 2022, 23
  • [43] A SIMPLE METHOD FOR CALIBRATING A RADIAL GATE FOR USE AS A FLOW MEASURING DEVICE
    Bonaiti, G.
    Karimov, A.
    Fipps, G.
    APPLIED ENGINEERING IN AGRICULTURE, 2018, 34 (02) : 379 - 388
  • [44] Correlation of Radial Flow-Through and Hollow Cylinder Dynamic Pressurization Test for Measuring Permeability
    Jones, Christopher A.
    Grasley, Zachary C.
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2009, 21 (10) : 594 - 600
  • [45] A method for measuring Darcian flow permeability of thin compressed fibre mats
    Koivu, Viivi
    Mattila, Keijo
    Kataja, Markku
    NORDIC PULP & PAPER RESEARCH JOURNAL, 2009, 24 (04) : 395 - 402
  • [46] Measuring system resilience through a comparison of information- and flow-based network analyses
    Hyde G.
    Fath B.D.
    Zoller H.
    Scientific Reports, 14 (1)
  • [47] Study on gas permeability coefficient measurement of coal seam by radial flow method
    Zhang Shuchuan
    2ND INTERNATIONAL CONFERENCE ON MATERIALS SCIENCE, ENERGY TECHNOLOGY AND ENVIRONMENTAL ENGINEERING (MSETEE 2017), 2017, 81
  • [48] Carrier gas flow arrangement based photoacoustic detection method for measuring gas permeability of polymer membranes
    Filus, Zoltan
    Toth, Nikolett
    Gulyas, Gabor
    Guba, Tibor
    Szabo, Gabor
    Bozoki, Zoltan
    POLYMER TESTING, 2013, 32 (06) : 1099 - 1104
  • [50] Flow-based method for the determination of biomarkers urea and ammoniacal nitrogen in saliva
    Thepchuay, Yanisa
    Costa, Carolina F. F. A.
    Mesquita, Raquel B. R.
    Sampaio-Maia, Benedita
    Nacapricha, Duangjai
    Rangel, Antonio O. S. S.