Agreement of Central Corneal Thickness Measurements between Scheimpflug Photography and Optical Low-Coherence Reflectometry in Children

被引:4
|
作者
Hashemi, Hassan [1 ]
Nabovati, Payam [2 ]
Khabazkhoob, Mehdi [3 ]
Emamian, Mohammad Hassan [4 ]
Yekta, Abbasali [5 ]
Fotouhi, Akbar [6 ]
机构
[1] Noor Eye Hosp, Noor Res Ctr Ophthalm Epidemiol, Tehran, Iran
[2] Iran Univ Med Sci, Rehabil Res Ctr, Sch Rehabil Sci, Dept Optometry, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Sch Nursing & Midwifery, Dept Med Surg Nursing, Tehran, Iran
[4] Shahroud Univ Med Sci, Ophthalm Epidemiol Res Ctr, Shahroud, Iran
[5] Mashhad Univ Med Sci, Refract Errors Res Ctr, Sch Paramed Sci, Mashhad, Razavi Khorasan, Iran
[6] Univ Tehran Med Sci, Sch Publ Hlth, Dept Epidemiol & Biostat, Tehran, Iran
关键词
Corneal thickness; corneal imaging; agreement; children; Iran; ULTRASOUND PACHYMETRY; SPECULAR MICROSCOPY; PENTACAM; TOMOGRAPHY; LENSTAR; DEVICES;
D O I
10.1080/08820538.2020.1810288
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose Central corneal thickness (CCT) is a key indicator of the corneal health status and is therefore of clinical importance. The aim of the present study was to determine the agreement between Scheimpflug photography (SP) and optical low-coherence reflectometry (OLCR) systems in measuring the CCT in children. Methods In this cross-sectional study, the samples were selected from Shahroud schoolchildren using cluster sampling. The samples then underwent optometric examinations, including the measurement of visual acuity and refraction. CCT measurements were done by the SP and OLCR systems between 8 am and 4 pm. To evaluate the agreement between these devices, 95% limits of agreement (LoA) and interclass correlation coefficient (ICC) were reported. Results After applying the exclusion criteria, 4890 right eyes (53.2% male) were analyzed. The mean age of the students was 9.22 +/- 1.72 years (range: 6-12 years). The mean CCT by the SP and OLCR systems was 555.30 +/- 34.15 and 550.23 +/- 35.11 mu m, respectively. The 95% LoA between the two devices was -19.81 to 9.66 mu m, and the ICC was 0.983. The CCT difference between the SP and OLCR systems was 5.61 mu m in boys and 3.36 mu m in girls. The CCT difference between the two devices was 6.41 mu m in 6-year-old and 3.54 mu m in 12-year-old children. The 95% LoA was -17.96 to 9.58 mu m and -18.89 to 8.47 mu m and the ICC was 0.987 and 0.984 in myopic and hyperopic subjects, respectively. Conclusion The results of this study showed a high agreement between OLCR and SP measurements of CCT in children.
引用
收藏
页码:252 / 256
页数:5
相关论文
共 50 条
  • [21] SIMULTANEOUS THICKNESS AND GROUP INDEX MEASUREMENT USING OPTICAL LOW-COHERENCE REFLECTOMETRY
    SORIN, WV
    GRAY, DF
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1992, 4 (01) : 105 - 107
  • [22] Measurement of Central Corneal Thickness With Optical Low-Coherence Reflectometry and Ultrasound Pachymetry in Normal and Post-Femtosecond Laser in Situ Keratomileusis Eyes
    Huang, Jinhai
    Liao, Na
    Savini, Giacomo
    Li, Yuanguang
    Bao, Fangjun
    Yu, Ye
    Yu, Ayong
    Wang, Qinmei
    CORNEA, 2015, 34 (02) : 204 - 208
  • [23] Multilayer optical storage by low-coherence reflectometry
    Chinn, SR
    Swanson, EA
    OPTICS LETTERS, 1996, 21 (12) : 899 - 901
  • [24] MEASUREMENT OF CORNEAL THICKNESS BY LOW-COHERENCE INTERFEROMETRY
    HITZENBERGER, CK
    APPLIED OPTICS, 1992, 31 (31): : 6637 - 6642
  • [25] Measurement of corneal thickness by low coherence reflectometry
    Bohnke, M
    Walti, R
    Lindgren, F
    Gianotti, R
    Bonvin, P
    Salathe, RP
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1998, 212 (05) : 367 - 371
  • [26] Measurement agreement between a new biometer based on partial coherence interferometry and a validated biometer based on optical low-coherence reflectometry
    Li, Junhua
    Chen, Hao
    Savini, Giacomo
    Lu, Weicong
    Yu, Xinxin
    Bao, Fangjun
    Wang, Qinmei
    Huang, Jinhai
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01): : 68 - 75
  • [27] A Comparison between Scheimpflug Imaging and Optical Coherence Tomography in Measuring Corneal Thickness
    Huang, Jinhai
    Ding, Xixia
    Savini, Giacomo
    Pan, Chao
    Feng, Yifan
    Cheng, Dan
    Hua, Yanjun
    Hu, Xiuli
    Wang, Qinmei
    OPHTHALMOLOGY, 2013, 120 (10) : 1951 - 1958
  • [29] Correlation of Choroidal Thickness and Volume Measurements with Axial Length and Age Using Swept Source Optical Coherence Tomography and Optical Low-Coherence Reflectometry
    Michalewski, Janusz
    Michalewska, Zofia
    Nawrocka, Zofia
    Bednarski, Maciej
    Nawrocki, Jerzy
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [30] Comparison of anterior segment measurements with rotating Scheimpflug photography and partial coherence reflectometry
    Huang, Jinhai
    Pesudovs, Konrad
    Wen, Daizong
    Chen, Shihao
    Wright, Thomas
    Wang, Xiaoyu
    Li, Yini
    Wang, Qinmei
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02): : 341 - 348