Semi-active neurocontrol of a base-isolated benchmark structure

被引:38
|
作者
Lee, Heon-Jae [1 ]
Yang, Guangqiang
Jung, Hyung-Jo
Spencer, Billie F., Jr.
Lee, In-Won
机构
[1] Korea Adv Inst Sci & Technol, Dept Civil & Environm Engn, Taejon 305701, South Korea
[2] Univ Illinois, Dept Civil & Environm Engn, Urbana, IL 61801 USA
[3] Sejong Univ, Dept Civil & Environm Engn, Seoul 143747, South Korea
来源
STRUCTURAL CONTROL & HEALTH MONITORING | 2006年 / 13卷 / 2-3期
关键词
semi-active control; neuro-control; base-isolation; benchmark problem; MR dampers; semiactive damping devices;
D O I
10.1002/stc.105
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, a new semi-active control strategy for seismic response reduction using a neurocontroller and MR dampers is proposed. The proposed control system adopts a training algorithm based on a cost function and sensitivity evaluation algorithm to calculate the desired control force. A clipped algorithm is then employed to induce the MR damper to generate approximately the desired control force by selecting appropriate command voltage. The proposed semi-active neurocontroller was applied to a benchmark building installed with linear elastomeric isolation system. Comparing with passive and sample controller, numerical simulation results have shown that the proposed scheme can significantly reduce the floor acceleration, base shear and building corner drift with a slight increase of base displacement. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:682 / 692
页数:11
相关论文
共 50 条
  • [41] Ground motion pulse-based active control of a linear base-isolated benchmark building
    Agrawal, AK
    Xu, Z
    He, WL
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 792 - 808
  • [42] A semi-active controller tuning and application to base seismically-isolated structures
    Teodorescu, C. -S.
    Diop, S.
    Politopoulos, I.
    Benidir, M.
    2013 EUROPEAN CONTROL CONFERENCE (ECC), 2013, : 3258 - 3263
  • [43] A robust nonlinear semi-active control for base seismically-isolated structures
    Teodorescu, C. -S.
    Diop, S.
    Politopoulos, I.
    Benidir, M.
    2013 21ST MEDITERRANEAN CONFERENCE ON CONTROL AND AUTOMATION (MED), 2013, : 545 - 550
  • [44] Response mitigation of the base isolated benchmark building by semi-active control with the viscous-plus-variable-friction damping force algorithm
    Ruangrassamee, Anat
    Srisamai, Weerasit
    Lukkunaprasit, Panitan
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 809 - 822
  • [45] ACTIVE CONTROL OF NONLINEAR BASE-ISOLATED BUILDINGS
    BARBAT, AH
    RODELLAR, J
    RYAN, EP
    MOLINARES, N
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 1995, 121 (06): : 676 - 684
  • [46] Hysteretic active control of base-isolated buildings
    Pozo, Francesc
    Vidal, Yolanda
    Garcia, Guillem
    Acho, Leonardo
    Rodellar, Jose
    STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (08):
  • [47] Performance of variable curvature sliding isolators in base-isolated benchmark building
    Sharma, Ajay
    Jangid, R. S.
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2012, 21 (05): : 354 - 373
  • [48] Seismic Response of Base-Isolated Benchmark Building with Variable Sliding Isolators
    Sharma, Ajay
    Jangid, R. S.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2010, 14 (07) : 1063 - 1091
  • [49] Application of angular-mass dampers to base-isolated benchmark building
    Pradono, Mulyo Harris
    Iemura, Hirokazu
    Igarashi, Akira
    Kalantari, Afshin
    STRUCTURAL CONTROL & HEALTH MONITORING, 2008, 15 (05): : 737 - 745
  • [50] Prediction of observed response of base-isolated structure
    Makris, N
    Deoskar, HS
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1996, 122 (05): : 485 - 493