Semi-active neurocontrol of a base-isolated benchmark structure

被引:38
|
作者
Lee, Heon-Jae [1 ]
Yang, Guangqiang
Jung, Hyung-Jo
Spencer, Billie F., Jr.
Lee, In-Won
机构
[1] Korea Adv Inst Sci & Technol, Dept Civil & Environm Engn, Taejon 305701, South Korea
[2] Univ Illinois, Dept Civil & Environm Engn, Urbana, IL 61801 USA
[3] Sejong Univ, Dept Civil & Environm Engn, Seoul 143747, South Korea
来源
STRUCTURAL CONTROL & HEALTH MONITORING | 2006年 / 13卷 / 2-3期
关键词
semi-active control; neuro-control; base-isolation; benchmark problem; MR dampers; semiactive damping devices;
D O I
10.1002/stc.105
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, a new semi-active control strategy for seismic response reduction using a neurocontroller and MR dampers is proposed. The proposed control system adopts a training algorithm based on a cost function and sensitivity evaluation algorithm to calculate the desired control force. A clipped algorithm is then employed to induce the MR damper to generate approximately the desired control force by selecting appropriate command voltage. The proposed semi-active neurocontroller was applied to a benchmark building installed with linear elastomeric isolation system. Comparing with passive and sample controller, numerical simulation results have shown that the proposed scheme can significantly reduce the floor acceleration, base shear and building corner drift with a slight increase of base displacement. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:682 / 692
页数:11
相关论文
共 50 条
  • [21] A novel robust optimum control algorithm and its application to semi-active controlled base-isolated structures
    Dongbin Zhang
    Peng Pan
    Yi Zeng
    Youming Guo
    Bulletin of Earthquake Engineering, 2020, 18 : 2431 - 2460
  • [22] Application of some semi-active control algorithms to a smart base-isolated building employing MR dampers
    Jung, Hyung-Jo
    Choi, Kang-Min
    Spencer, Billie F., Jr.
    Lee, In-Won
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 693 - 704
  • [23] Seismic reduction of semi-active base-isolated structures based on multi-level fuzzy control
    Zhao D.-H.
    Li Y.-X.
    Li H.-N.
    Qian H.
    Li, Yong-Xing, 1600, Chinese Vibration Engineering Society (35): : 78 - 84
  • [24] Development of distributed tunable friction pendulum system (DTFPS) for semi-active control of base-isolated buildings
    Zeng, Yi
    Pan, Peng
    Guo, Youming
    BULLETIN OF EARTHQUAKE ENGINEERING, 2021, 19 (14) : 6243 - 6268
  • [25] Hyperbolic control for vibration mitigation of a base-isolated benchmark structure
    Pozo, Francesc
    Acho, Leonardo
    Rodellar, Jose
    STRUCTURAL CONTROL & HEALTH MONITORING, 2009, 16 (7-8): : 766 - 783
  • [26] Semi-active base isolation for a building structure
    Yoshida, K
    Fujio, T
    INTERNATIONAL JOURNAL OF COMPUTER APPLICATIONS IN TECHNOLOGY, 2000, 13 (1-2) : 52 - 58
  • [27] Semi-active base isolation for a building structure
    Yoshida, Kazuo
    Fujio, Tadahiro
    International Journal of Computer Applications in Technology, 2000, 13 (01) : 52 - 58
  • [28] Real-time hybrid simulation for a base-isolated building with the transmissibility-based semi-active controller
    Rabiee, Ramin
    Chae, Yunbyeong
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2022, 33 (17) : 2228 - 2240
  • [29] Semi-active control of nonlinear smart base-isolated structures using MR damper: sensitivity and reliability analyses
    Etedali, Sadegh
    Zamani, Abbas-Ali
    SMART MATERIALS AND STRUCTURES, 2022, 31 (06)
  • [30] Assessment of a base-isolated structure with semi-active low-cost viscous fluid dampers through real-time hybrid simulations
    Vides, S.
    Castillo, B.
    Artunduaga, A.
    Marulanda, J.
    Thomson, P.
    INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2025, 10 (04)