Endoscopic ultrasound-guided tissue sampling by combined fine needle aspiration and trucut needle biopsy: a prospective study

被引:127
|
作者
Wittmann, J
Kocjan, G
Sgouros, SN
Deheragoda, M
Pereira, SP
机构
[1] UCL, London Med Sch, Inst Hepatol, London WC1E 6HX, England
[2] UCL, Dept Gastroenterol, London WC1E 6HX, England
[3] UCL, Dept Cytopathol, London WC1E 6HX, England
[4] UCL, Dept Histopathol, London WC1E 6HX, England
[5] Royal Free & UCL Med Sch, UCL Inst Hepatol, London, England
关键词
endoscopic ultrasound; fine needle aspiration; trucut needle biopsy; accuracy; safety; EUS FNA; EUS FNAC;
D O I
10.1111/j.1365-2303.2006.00313.x
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Background and aims: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) has a diagnostic accuracy of 70-90%, depending on the site under evaluation. In order to improve EUS-guided tissue sampling a novel 19-gauge trucut-type needle has been designed to obtain core biopsies during EUS. We prospectively evaluated the safety and accuracy of EUS-FNA alone versus combined EUS-FNA and trucut needle biopsy (TNB) in patients referred to our Unit over a 3-year period. Patients and methods: A total of 159 patients underwent EUS-FNA alone (lesions < 2 cm) or the combination of both sampling modalities (lesions >= 2 cm). The adequacy of sampling, sensitivity, specificity and overall accuracies of EUS-FNA or EUS-TNB alone and combined EUS-FNA/TNB were determined. Results: Adequate samples were obtained by EUS-FNA, EUS-TNB and EUS-FNA/TNB in 91%, 88% and 97% of patients, respectively. From the pancreas (n = 83), adequate samples were obtained by FNA in 94% and by TNB in 81%, compared with 87% and 92% from non-pancreatic sites (n = 76), respectively. The combination of both techniques resulted in more adequate samples from non-pancreatic cases than EUS-FNA alone (P = 0.044). The specificity was 100%. Overall accuracy for EUS-FNA alone was 77%, for EUS-TNB alone 73% and for EUS-FNA/TNB 91% (P = 0.008). For pancreatic sampling, the accuracy of EUS-FNA alone was 77%, for EUS-TNB alone 56% and for EUS-FNA/TNB 83%. For non-pancreatic sampling, the accuracy for EUS-FNA alone was 78%, for EUS-TNB alone 83% and for EUS-FNA/TNB 95% (P = 0.006). The complication rate was 0.6%. Conclusions: Combined EUS-FNA/TNB for lesions >= 2 cm improves adequacy of sampling and diagnostic accuracy compared with either technique alone and is safe.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 50 条
  • [41] Comparison of endoscopic ultrasound guided Fine-Needle Aspiration cytology vs. trucut biopsy
    Pereira, TC
    Levy, M
    Souza, PC
    Clayton, AC
    MODERN PATHOLOGY, 2006, 19 : 69A - 69A
  • [42] Comparison of endoscopic ultrasound guided Fine-Needle Aspiration cytology vs.trucut biopsy
    Pereira, TC
    Levy, M
    Souza, PC
    Clayton, AC
    LABORATORY INVESTIGATION, 2006, 86 : 69A - 69A
  • [43] Endoscopic ultrasound guided fine needle aspiration versus endoscopic ultrasound guided fine needle biopsy in sampling pancreatic masses A meta-analysis
    Wang, Jing
    Zhao, Shulei
    Chen, Yong
    Jia, Ruzhen
    Zhang, Xiaohua
    MEDICINE, 2017, 96 (28)
  • [44] In memoriam: Fine-needle aspiration, birth: Fine-needle biopsy: The changing trend in endoscopic ultrasound-guided tissue acquisition
    Bang, Ji Young
    Kirtane, Sachin
    Krall, Konrad
    Navaneethan, Udayakumar
    Hasan, Muhammad
    Hawes, Robert
    Varadarajulu, Shyam
    DIGESTIVE ENDOSCOPY, 2019, 31 (02) : 197 - 202
  • [45] Comparative Study of an Ultrasound-guided Percutaneous Biopsy and Endoscopic Ultrasound-guided Fine-needle Aspiration for Liver Tumors
    Takano, Yuichi
    Noda, Jun
    Yamawaki, Masataka
    Azami, Tetsushi
    Kobayashi, Takahiro
    Niiya, Fumitaka
    Maruoka, Naotaka
    Norose, Tomoko
    Ohike, Nobuyuki
    Wakabayashi, Tetsuji
    Matsuo, Kenichi
    Tanaka, Kuniya
    Nagahama, Masatsugu
    INTERNAL MEDICINE, 2021, 60 (11) : 1657 - 1664
  • [46] Role of endoscopic ultrasound-guided fine needle aspiration and ultrasound-guided fine-needle aspiration in diagnosis of cystic pancreatic lesions
    Okasha, Hussein Hassan
    Ashry, Mahmoud
    Imam, Hala M. K.
    Ezzat, Reem
    Naguib, Mohamed
    Farag, Ali H.
    Gemeie, Emad H.
    Khattab, Hani M.
    ENDOSCOPIC ULTRASOUND, 2015, 4 (02) : 132 - 136
  • [47] Endoscopic Ultrasound-Guided Fine Needle Aspiration versus Percutaneous Ultrasound-Guided Fine Needle Aspiration in Diagnosis of Focal Pancreatic Masses
    Okasha, Hussein Hassan
    Naga, Mazen Ibrahim
    Esmat, Serag
    Naguib, Mohamed
    Hassanein, Mohamed
    Hassani, Mohamed
    El-Kassas, Mohamed
    Mahdy, Reem Ezzat
    El-Gemeie, Emad
    Farag, Ali Hassan
    Foda, Ayman Mohamed
    ENDOSCOPIC ULTRASOUND, 2013, 2 (04) : 190 - 193
  • [48] Evalutation of fine needle aspiration vs. fine needle capillary sampling on specimen quality and diagnostic accuracy in endoscopic ultrasound-guided biopsy
    Storch, Ian Michael
    Sussman, Daniel Andrew
    Jorda, Merce
    Ribeiro, Afonso
    ACTA CYTOLOGICA, 2007, 51 (06) : 837 - 842
  • [49] ULTRASOUND-GUIDED FINE NEEDLE ASPIRATION BIOPSY AND FINE NEEDLE CUTTING BIOPSY - CLINICAL EFFICACY IN ONCOLOGY
    WANDT, H
    GRUMMICH, H
    FALGE, C
    ZIPPEL, R
    GALLMEIER, WM
    WUNSCH, PH
    TUMORDIAGNOSTIK & THERAPIE, 1991, 12 (02) : 79 - 82
  • [50] A new biopsy handle instrument for endoscopic ultrasound-guided fine-needle aspiration biopsy
    Vilmann, P
    Hancke, S
    GASTROINTESTINAL ENDOSCOPY, 1996, 43 (03) : 238 - 242