Endoscopic ultrasound-guided tissue sampling by combined fine needle aspiration and trucut needle biopsy: a prospective study

被引:127
|
作者
Wittmann, J
Kocjan, G
Sgouros, SN
Deheragoda, M
Pereira, SP
机构
[1] UCL, London Med Sch, Inst Hepatol, London WC1E 6HX, England
[2] UCL, Dept Gastroenterol, London WC1E 6HX, England
[3] UCL, Dept Cytopathol, London WC1E 6HX, England
[4] UCL, Dept Histopathol, London WC1E 6HX, England
[5] Royal Free & UCL Med Sch, UCL Inst Hepatol, London, England
关键词
endoscopic ultrasound; fine needle aspiration; trucut needle biopsy; accuracy; safety; EUS FNA; EUS FNAC;
D O I
10.1111/j.1365-2303.2006.00313.x
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Background and aims: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) has a diagnostic accuracy of 70-90%, depending on the site under evaluation. In order to improve EUS-guided tissue sampling a novel 19-gauge trucut-type needle has been designed to obtain core biopsies during EUS. We prospectively evaluated the safety and accuracy of EUS-FNA alone versus combined EUS-FNA and trucut needle biopsy (TNB) in patients referred to our Unit over a 3-year period. Patients and methods: A total of 159 patients underwent EUS-FNA alone (lesions < 2 cm) or the combination of both sampling modalities (lesions >= 2 cm). The adequacy of sampling, sensitivity, specificity and overall accuracies of EUS-FNA or EUS-TNB alone and combined EUS-FNA/TNB were determined. Results: Adequate samples were obtained by EUS-FNA, EUS-TNB and EUS-FNA/TNB in 91%, 88% and 97% of patients, respectively. From the pancreas (n = 83), adequate samples were obtained by FNA in 94% and by TNB in 81%, compared with 87% and 92% from non-pancreatic sites (n = 76), respectively. The combination of both techniques resulted in more adequate samples from non-pancreatic cases than EUS-FNA alone (P = 0.044). The specificity was 100%. Overall accuracy for EUS-FNA alone was 77%, for EUS-TNB alone 73% and for EUS-FNA/TNB 91% (P = 0.008). For pancreatic sampling, the accuracy of EUS-FNA alone was 77%, for EUS-TNB alone 56% and for EUS-FNA/TNB 83%. For non-pancreatic sampling, the accuracy for EUS-FNA alone was 78%, for EUS-TNB alone 83% and for EUS-FNA/TNB 95% (P = 0.006). The complication rate was 0.6%. Conclusions: Combined EUS-FNA/TNB for lesions >= 2 cm improves adequacy of sampling and diagnostic accuracy compared with either technique alone and is safe.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 50 条
  • [31] Comparison of Ultrasound-Guided Core Needle Biopsy and Endoscopic Ultrasound-Guided Fine-Needle Aspiration for Solid Pancreatic Lesions
    Sur, Young Keun
    Kim, Young Chul
    Kim, Jai Keun
    Lee, Jei Hee
    Yoo, Byung Moo
    Kim, Young Bae
    JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (12) : 2163 - 2169
  • [32] Endoscopic ultrasound-guided sampling of solid pancreatic masses: the fine needle aspiration or fine needle biopsy dilemma. Is the best needle yet to come?
    Conti, Clara Benedetta
    Cereatti, Fabrizio
    Grassia, Roberto
    WORLD JOURNAL OF GASTROINTESTINAL ENDOSCOPY, 2019, 11 (08): : 454 - 471
  • [33] Endoscopic Ultrasound-Guided Fine Needle Aspiration and Tru-Cut Biopsy
    Vilmann, Peter
    Puri, Rajesh
    TECHNIQUES IN GASTROINTESTINAL ENDOSCOPY, 2007, 9 (01) : 2 - 19
  • [34] Endoscopic ultrasound-guided fine needle aspiration: How to obtain a core biopsy?
    Fuccio, Lorenzo
    Larghil, Alberto
    ENDOSCOPIC ULTRASOUND, 2014, 3 (02) : 71 - 81
  • [35] Endoscopic ultrasound-guided fine-needle aspiration biopsy in esophageal cancer
    Klapman, J
    Chang, KJ
    Wiersema, M
    Murata, Y
    Vilmann, P
    ENDOSCOPY, 2005, 37 (04) : 381 - 385
  • [36] Endoscopic Ultrasound-Guided Fine Needle Aspiration: Single vs. Combined Needle Approach
    Iqbal, Shahzad
    Kapoor, Anuj
    Oberoi, Gulshan
    Stevens, Peter
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2009, 104 : S518 - S518
  • [37] Endoscopic Ultrasound-Guided Fine Needle Aspiration and Biopsy in Gastrointestinal Subepithelial Tumors
    Pih, Gyu Young
    Kim, Do Hoon
    CLINICAL ENDOSCOPY, 2019, 52 (04) : 314 - 320
  • [38] Endoscopic ultrasound-guided fine needle aspiration cytology and biopsy in the evaluation of lymphoma
    Gimeno-Garcia, Antonio Z.
    Elwassief, Ahmed
    Paquin, Sarto C.
    Sahai, Anand V.
    ENDOSCOPIC ULTRASOUND, 2012, 1 (01) : 17 - 22
  • [39] Sampling of the adrenal glands by endoscopic ultrasound-guided fine-needle aspiration
    Stelow, EB
    Debol, SM
    Stanley, MW
    Mallery, S
    Lai, R
    Bardales, RH
    DIAGNOSTIC CYTOPATHOLOGY, 2005, 33 (01) : 26 - 30
  • [40] Endoscopic ultrasound-guided liver biopsy using a 22-G fine needle biopsy needle: a prospective study
    Hasan, Muhammad K.
    Kadkhodayan, Kambiz
    Idrisov, Evgeny
    Ali, Saeed
    Rafiq, Ehsan
    Shor, Dana Ben-Ami
    Abdel-Jalil, Ala
    Navaneethan, Uday
    Bang, Ji
    Varadarajulu, Shyam
    Hawes, Robert
    Pernicone, Peter
    ENDOSCOPY, 2019, 51 (09) : 818 - 824