Endoscopic ultrasound-guided tissue sampling by combined fine needle aspiration and trucut needle biopsy: a prospective study

被引:127
|
作者
Wittmann, J
Kocjan, G
Sgouros, SN
Deheragoda, M
Pereira, SP
机构
[1] UCL, London Med Sch, Inst Hepatol, London WC1E 6HX, England
[2] UCL, Dept Gastroenterol, London WC1E 6HX, England
[3] UCL, Dept Cytopathol, London WC1E 6HX, England
[4] UCL, Dept Histopathol, London WC1E 6HX, England
[5] Royal Free & UCL Med Sch, UCL Inst Hepatol, London, England
关键词
endoscopic ultrasound; fine needle aspiration; trucut needle biopsy; accuracy; safety; EUS FNA; EUS FNAC;
D O I
10.1111/j.1365-2303.2006.00313.x
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Background and aims: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) has a diagnostic accuracy of 70-90%, depending on the site under evaluation. In order to improve EUS-guided tissue sampling a novel 19-gauge trucut-type needle has been designed to obtain core biopsies during EUS. We prospectively evaluated the safety and accuracy of EUS-FNA alone versus combined EUS-FNA and trucut needle biopsy (TNB) in patients referred to our Unit over a 3-year period. Patients and methods: A total of 159 patients underwent EUS-FNA alone (lesions < 2 cm) or the combination of both sampling modalities (lesions >= 2 cm). The adequacy of sampling, sensitivity, specificity and overall accuracies of EUS-FNA or EUS-TNB alone and combined EUS-FNA/TNB were determined. Results: Adequate samples were obtained by EUS-FNA, EUS-TNB and EUS-FNA/TNB in 91%, 88% and 97% of patients, respectively. From the pancreas (n = 83), adequate samples were obtained by FNA in 94% and by TNB in 81%, compared with 87% and 92% from non-pancreatic sites (n = 76), respectively. The combination of both techniques resulted in more adequate samples from non-pancreatic cases than EUS-FNA alone (P = 0.044). The specificity was 100%. Overall accuracy for EUS-FNA alone was 77%, for EUS-TNB alone 73% and for EUS-FNA/TNB 91% (P = 0.008). For pancreatic sampling, the accuracy of EUS-FNA alone was 77%, for EUS-TNB alone 56% and for EUS-FNA/TNB 83%. For non-pancreatic sampling, the accuracy for EUS-FNA alone was 78%, for EUS-TNB alone 83% and for EUS-FNA/TNB 95% (P = 0.006). The complication rate was 0.6%. Conclusions: Combined EUS-FNA/TNB for lesions >= 2 cm improves adequacy of sampling and diagnostic accuracy compared with either technique alone and is safe.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 50 条
  • [21] ULTRASOUND-GUIDED FINE NEEDLE ASPIRATION BIOPSY OF THE LIVER
    LIN, BPC
    CHU, JMG
    ROSE, RA
    PATHOLOGY, 1987, 19 (02) : 173 - 177
  • [22] ENDOSCOPIC ULTRASOUND-GUIDED FINE-NEEDLE ASPIRATION
    CHANG, KJ
    KATZ, KD
    DURBIN, TE
    ERICKSON, RA
    BUTLER, JA
    LIN, F
    WUERKER, RB
    GASTROINTESTINAL ENDOSCOPY, 1994, 40 (06) : 694 - 699
  • [23] Endoscopic ultrasound-guided fine needle aspiration of the liver
    Cameron, S. E. H.
    Evans, R. A.
    Debol, S. M.
    Mallery, S.
    Stelow, E. B.
    MODERN PATHOLOGY, 2007, 20 : 65A - 65A
  • [24] Endoscopic ultrasound-guided fine-needle aspiration
    Eloubeidi, MA
    Vilmann, P
    Wiersema, MJ
    ENDOSCOPY, 2004, 36 (10) : 901 - 908
  • [25] Endoscopic ultrasound-guided fine-needle aspiration
    Schanz, S
    Kruis, W
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2005, 130 (34-35) : 1957 - 1961
  • [26] Training in endoscopic ultrasound-guided fine needle aspiration
    Paquin, Sarto C.
    ENDOSCOPIC ULTRASOUND, 2014, 3 (01) : 12 - 16
  • [27] Endoscopic Ultrasound-guided Tissue Acquisition of Solid Mass Lesions of Pancreas: A Retrospective Comparison Study of Fine Needle Aspiration and Fine Needle Biopsy
    Sweeney, Jacob
    Soong, Lauren
    Goyal, Abha
    MODERN PATHOLOGY, 2019, 32
  • [28] Endoscopic ultrasound-guided fine-needle aspiration
    Stanley, MW
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2003, 120 (03) : 309 - 310
  • [29] Endoscopic ultrasound-guided fine needle aspiration of the liver
    Cameron, S. E. H.
    Evans, R. A.
    Debol, S. M.
    Mallery, S.
    Stelow, E. B.
    LABORATORY INVESTIGATION, 2007, 87 : 65A - 65A
  • [30] Endoscopic Ultrasound-guided Tissue Acquisition of Solid Mass Lesions of Pancreas: A Retrospective Comparison Study of Fine Needle Aspiration and Fine Needle Biopsy
    Sweeney, Jacob
    Soong, Lauren
    Goyal, Abha
    LABORATORY INVESTIGATION, 2019, 99