Endoscopic ultrasound-guided tissue sampling by combined fine needle aspiration and trucut needle biopsy: a prospective study

被引:127
|
作者
Wittmann, J
Kocjan, G
Sgouros, SN
Deheragoda, M
Pereira, SP
机构
[1] UCL, London Med Sch, Inst Hepatol, London WC1E 6HX, England
[2] UCL, Dept Gastroenterol, London WC1E 6HX, England
[3] UCL, Dept Cytopathol, London WC1E 6HX, England
[4] UCL, Dept Histopathol, London WC1E 6HX, England
[5] Royal Free & UCL Med Sch, UCL Inst Hepatol, London, England
关键词
endoscopic ultrasound; fine needle aspiration; trucut needle biopsy; accuracy; safety; EUS FNA; EUS FNAC;
D O I
10.1111/j.1365-2303.2006.00313.x
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Background and aims: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) has a diagnostic accuracy of 70-90%, depending on the site under evaluation. In order to improve EUS-guided tissue sampling a novel 19-gauge trucut-type needle has been designed to obtain core biopsies during EUS. We prospectively evaluated the safety and accuracy of EUS-FNA alone versus combined EUS-FNA and trucut needle biopsy (TNB) in patients referred to our Unit over a 3-year period. Patients and methods: A total of 159 patients underwent EUS-FNA alone (lesions < 2 cm) or the combination of both sampling modalities (lesions >= 2 cm). The adequacy of sampling, sensitivity, specificity and overall accuracies of EUS-FNA or EUS-TNB alone and combined EUS-FNA/TNB were determined. Results: Adequate samples were obtained by EUS-FNA, EUS-TNB and EUS-FNA/TNB in 91%, 88% and 97% of patients, respectively. From the pancreas (n = 83), adequate samples were obtained by FNA in 94% and by TNB in 81%, compared with 87% and 92% from non-pancreatic sites (n = 76), respectively. The combination of both techniques resulted in more adequate samples from non-pancreatic cases than EUS-FNA alone (P = 0.044). The specificity was 100%. Overall accuracy for EUS-FNA alone was 77%, for EUS-TNB alone 73% and for EUS-FNA/TNB 91% (P = 0.008). For pancreatic sampling, the accuracy of EUS-FNA alone was 77%, for EUS-TNB alone 56% and for EUS-FNA/TNB 83%. For non-pancreatic sampling, the accuracy for EUS-FNA alone was 78%, for EUS-TNB alone 83% and for EUS-FNA/TNB 95% (P = 0.006). The complication rate was 0.6%. Conclusions: Combined EUS-FNA/TNB for lesions >= 2 cm improves adequacy of sampling and diagnostic accuracy compared with either technique alone and is safe.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 50 条
  • [1] Endoscopic ultrasound guided tissue sampling by combined fine needle aspiration and trucut needle biopsy for the diagnosis of pancreatic neuroendocrine tumours
    Sgouros, S. N.
    Caplin, M.
    Pereira, S. P.
    GUT, 2007, 56 : A76 - A76
  • [2] Endoscopic ultrasound-guided fine-needle aspiration biopsy and trucut biopsy in gastroenterology - An overview
    Jenssen, Christian
    Dietrich, Christoph F.
    BEST PRACTICE & RESEARCH CLINICAL GASTROENTEROLOGY, 2009, 23 (05) : 743 - 759
  • [3] Randomized study comparing endoscopic ultrasound-guided Trucut biopsy and fine needle aspiration with high suction
    Gerke, H.
    Rizk, M. K.
    Vanderheyden, A. D.
    Jensen, C. S.
    CYTOPATHOLOGY, 2010, 21 (01) : 44 - 51
  • [4] Endoscopic ultrasound-guided fine-needle aspiration and Trucut biopsy in thoracic lesions: When tissue is the issue
    Ian Storch
    Mubashir Shah
    R. Thurer
    Elio Donna
    A. Ribeiro
    Surgical Endoscopy, 2008, 22 : 86 - 90
  • [5] Endoscopic ultrasound-guided fine-needle aspiration and Trucut biopsy in thoracic lesions: When tissue is the issue
    Storch, Ian
    Shah, Mubashir
    Thurer, R.
    Donna, Elio
    Ribeiro, A.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2008, 22 (01): : 86 - 90
  • [6] Endoscopic ultrasound-guided trucut biopsy versus endoscopic ultrasound-guided fine needle aspiration: an evaluation of 67 patients with mediastinal lesions
    Scheffer, R. C. H.
    Stolk, M. F. J.
    Seldenrijk, C. A.
    de Bruin, P.
    Timmer, R.
    Weusten, B. L. A. M.
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2008, 20 (07) : A24 - A24
  • [7] A prospective multi-centre study of the safety and accuracy of combined endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) and trucut needle biopsy (TNB)
    Tam, W
    Aithal, G
    Dean, J
    Pereira, SP
    GASTROINTESTINAL ENDOSCOPY, 2004, 59 (05) : AB212 - AB212
  • [8] Endoscopic ultrasound-guided fine needle aspiration or fine needle biopsy: the beauty is in the eye of the beholder
    Holt, Bronte
    Varadarajulu, Shyam
    ENDOSCOPY, 2014, 46 (12) : 1046 - 1048
  • [9] Comparison of endoscopic ultrasound-guided trucut biopsy (EUS-TCB) to endoscopic ultrasound-guided fine needle aspiration (EUS-FNA)
    Levy, MJ
    Wiersema, MJ
    Clain, JE
    Rajan, E
    Schwartz, DA
    Kumar, KS
    Gines, A
    GASTROINTESTINAL ENDOSCOPY, 2003, 57 (05) : AB244 - AB244
  • [10] Endoscopic Ultrasound-Guided Fine Needle Aspiration
    Brass, Volker
    Thimme, Robert
    Will, Uwe
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2017, 142 (05) : 371 - 375