Electrical impedance tomography for lung ventilation monitoring of the dog

被引:6
|
作者
Gloning, Simon [1 ]
Pieper, Korbinian [1 ]
Zoeliner, Martin [1 ]
Meyer-Lindenberg, Andrea [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Clin Small Anim Surg & Reprod, Munich, Germany
来源
关键词
Lung function; general anaesthesia; positive end-expiratory pressure; COMPUTED-TOMOGRAPHY; CT; QUANTITATION; EMPHYSEMA; PERFUSION; SURGERY; DENSITY; INJURY;
D O I
10.15654/TPK-150569
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background: Electrical impedance tomography (EIT) is a radiation free technique which takes advantage of the different electrical conductivities of different tissues. Its main field of application is lung ventilation monitoring. The aim of this prospective study was to evaluate the feasibility of collecting EIT information on a sample of dogs with different thoracic shapes under clinical conditions by connecting an electrode belt without fur clipping. Material and methods: Fifteen pulmonary healthy dogs were anaesthetized, positioned in sternal recumbency and ventilated in a pressure-controlled mode at three different positive end-expiratory pressure levels (PEEP) of 0, 5 and 10 cmH(2)O for five breaths each, with a peak inspiratory pressure of 15 cmH(2)O. The impedance changes were recorded with a commercial EIT device applied around the thorax. Subsequently, the ventilation regime was repeated and a computed tomography scan (CT) of the same thoracic segment was performed for each PEEP level. The tidal volume (Vi) was recorded. For the collection of EIT data the sum of regional impedance changes was recorded. The impedance value of the entire lung (global) was recorded and the ventilated area was quartered into four regions of interest (ROI). In a CT image with the fewest adjacent organs, lung tissue was selected to obtain the mean value of lung radiodensitiy in Hounsfield-Units (HU) for the entire lung and for the four ROls. Results: EIT recordings via the electrode belt were possible without clipping. There was a significant correlation for the parameters of aeration as measured by EIT and CT for both the entire ventilated lung and the corresponding ROls. The increasing PEEP resulted in a proportional increase of the impedance, and there was a negative correlation between EIT and V-t. The better ventilated dorsal ROls could be identified using both EIT and CT. An intra-assay coefficient of variation showed a good reproducibility for lung ventilation in anaesthetized dogs in the EIT. Discussion: The results show that EIT is a reliable method for evaluating the ventilation of dogs in a clinical setting. The accuracy of EIT might be improved by using a mesh corresponding to the different thoracic shapes of the dogs.
引用
收藏
页码:15 / 21
页数:7
相关论文
共 50 条
  • [31] Electrical impedance tomography - a method for monitoring regional lung function
    Frerichs, I
    TECHNISCHES MESSEN, 2004, 71 (09): : 519 - 526
  • [32] Image reconstruction for lung monitoring in wearable electrical impedance tomography
    Wocik, Dariusz
    Stefaniak, Barbara
    Wos, Michal
    Kiczek, Bartlomiej
    Rymarczyk, Tomasz
    PRZEGLAD ELEKTROTECHNICZNY, 2022, 98 (03): : 106 - 109
  • [33] Electrical Impedance Tomography for Confirmation of Lung Isolation during One-lung Ventilation
    Hempel, Gunther
    Schulze, Gero
    Wirtz, Hubert
    Wrigge, Hermann
    ANESTHESIOLOGY, 2018, 129 (03) : 580 - 580
  • [34] A 10.4 mW Electrical Impedance Tomography SoC for Portable Real-time Lung Ventilation Monitoring System
    Hong, Sunjoo
    Lee, Jaehyuk
    Bae, Joonsung
    Yoo, Hoi-Jun
    2014 IEEE ASIAN SOLID-STATE CIRCUITS CONFERENCE (A-SSCC), 2014, : 193 - 196
  • [35] A 10.4 mW Electrical Impedance Tomography SoC for Portable Real-Time Lung Ventilation Monitoring System
    Hong, Sunjoo
    Lee, Jaehyuk
    Bae, Joonsung
    Yoo, Hoi-Jun
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2015, 50 (11) : 2501 - 2512
  • [36] Reproducibility of regional lung ventilation distribution determined by electrical impedance tomography during mechanical ventilation
    Frerichs, I.
    Schmitz, G.
    Pulletz, S.
    Schaedler, D.
    Zick, G.
    Scholz, J.
    Weiler, N.
    PHYSIOLOGICAL MEASUREMENT, 2007, 28 (07) : S261 - S267
  • [37] Electrical impedance tomography as a tool for monitoring mechanical ventilation. An introduction to the technique
    Maciejewski, Dariusz
    Putowski, Zbigniew
    Czok, Marcelina
    Krzych, Lukasz J.
    ADVANCES IN MEDICAL SCIENCES, 2021, 66 (02): : 388 - 395
  • [38] Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography
    Frerichs, I
    Hahn, G
    Golisch, W
    Kurpitz, M
    Burchardi, H
    Hellige, G
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1998, 42 (06) : 721 - 726
  • [39] Redistribution of pulmonary ventilation after lung surgery detected with electrical impedance tomography
    Lehmann, Martin
    Oehler, Beatrice
    Zuber, Jonas
    Malzahn, Uwe
    Walles, Thorsten
    Muellenbach, Ralf M.
    Roewer, Norbert
    Kredel, Markus
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2020, 64 (04) : 517 - 525
  • [40] Methodology of electrical impedance tomography-derived measures of regional lung ventilation
    Frerichs, Inez
    Becher, Tobias
    Weiler, Norbert
    CRITICAL CARE, 2014, 18 (06):