A 10.4 mW Electrical Impedance Tomography SoC for Portable Real-time Lung Ventilation Monitoring System

被引:0
|
作者
Hong, Sunjoo [1 ]
Lee, Jaehyuk [1 ]
Bae, Joonsung [1 ]
Yoo, Hoi-Jun [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Elect Engn, Daejeon, South Korea
关键词
Electrical impedance tomography; ventilation monitoring; complex impedance; low power;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An electrical impedance tomography (EIT) SoC is proposed for the portable real-time lung ventilation monitoring system. The proposed SoC is integrated into belt-type EIT system with 32 electrodes and can show the dynamic images of the lung ventilation on the mobile devices. It has 3 key building blocks; 1) a T-switch for high off isolation >60 dB between electrodes, 2) a I/Q signal generation and demodulation for high fidelity image, and 3) an on-chip fast demodulation scheme to reduce scanning time and ADC speed. As a result, real and imaginary part of images can be reconstructed with 97.3% of accuracy and can be displayed on the mobile devices. The proposed EIT SoC of 5.0 mm x 5.0 mm is fabricated in 0.18 mu m CMOS technology, and consumes only 10.4 mW with 1.8 V supply.
引用
收藏
页码:193 / 196
页数:4
相关论文
共 50 条
  • [1] A 10.4 mW Electrical Impedance Tomography SoC for Portable Real-Time Lung Ventilation Monitoring System
    Hong, Sunjoo
    Lee, Jaehyuk
    Bae, Joonsung
    Yoo, Hoi-Jun
    [J]. IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2015, 50 (11) : 2501 - 2512
  • [2] Robust real-time inversion of electrical impedance tomography data for human lung ventilation monitoring
    Salucci, Marco
    Oliveri, Giacomo
    [J]. MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2019, 61 (01) : 5 - 8
  • [3] A 4.84mW 30fps Dual Frequency Division Multiplexing Electrical Impedance Tomography SoC for Lung Ventilation Monitoring System
    Lee, Yongsu
    Song, Kiseok
    Yoo, Hoi-Jun
    [J]. 2015 SYMPOSIUM ON VLSI CIRCUITS (VLSI CIRCUITS), 2015,
  • [4] Real-time ventilation and perfusion distributions by electrical impedance tomography during one-lung ventilation with capnothorax
    Reinius, H.
    Borges, J. B.
    Freden, F.
    Jideus, L.
    Camargo, E. D. L. B.
    Amato, M. B. P.
    Hedenstierna, G.
    Larsson, A.
    Lennmyr, F.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2015, 59 (03) : 354 - 368
  • [5] Electrical impedance tomography for lung ventilation monitoring of the dog
    Gloning, Simon
    Pieper, Korbinian
    Zoeliner, Martin
    Meyer-Lindenberg, Andrea
    [J]. TIERAERZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2017, 45 (01): : 15 - 21
  • [6] A parallel broadband real-time system for electrical impedance tomography
    Casas, O
    Rosell, J
    Bragos, R
    Lozano, A
    Riu, PJ
    [J]. PHYSIOLOGICAL MEASUREMENT, 1996, 17 : A1 - A6
  • [7] A real-time volumetric visualization system for electrical impedance tomography
    Briggs, NM
    Avis, NJ
    Kleinermann, F
    [J]. PHYSIOLOGICAL MEASUREMENT, 2000, 21 (01) : 27 - 33
  • [8] Evaluation and Real-Time Monitoring of Data Quality in Electrical Impedance Tomography
    Mamatjan, Yasin
    Grychtol, Bartlomiej
    Gaggero, Pascal
    Justiz, Joern
    Koch, Volker M.
    Adler, Andy
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (11) : 1997 - 2005
  • [9] An optimized strategy for real-time hemorrhage monitoring with electrical impedance tomography
    Xu, Canhua
    Dai, Meng
    You, Fusheng
    Shi, Xuetao
    Fu, Feng
    Liu, Ruigang
    Dong, Xiuzhen
    [J]. PHYSIOLOGICAL MEASUREMENT, 2011, 32 (05) : 585 - 598
  • [10] Real-Time 3D Electrical Impedance Imaging for Ventilation Monitoring of the Lung: Pilot study
    Amm, Bruce
    Kao, Tzu-Jen
    Wang, Xin
    Boverman, Gregory
    Shoudy, David
    Sabatini, James
    Ashe, Jeffrey
    Newell, Jonathan
    Saulnier, Gary
    Isaacson, David
    Davenport, David
    [J]. 2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 6064 - 6067