Electrical impedance tomography for lung ventilation monitoring of the dog

被引:6
|
作者
Gloning, Simon [1 ]
Pieper, Korbinian [1 ]
Zoeliner, Martin [1 ]
Meyer-Lindenberg, Andrea [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Clin Small Anim Surg & Reprod, Munich, Germany
来源
关键词
Lung function; general anaesthesia; positive end-expiratory pressure; COMPUTED-TOMOGRAPHY; CT; QUANTITATION; EMPHYSEMA; PERFUSION; SURGERY; DENSITY; INJURY;
D O I
10.15654/TPK-150569
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background: Electrical impedance tomography (EIT) is a radiation free technique which takes advantage of the different electrical conductivities of different tissues. Its main field of application is lung ventilation monitoring. The aim of this prospective study was to evaluate the feasibility of collecting EIT information on a sample of dogs with different thoracic shapes under clinical conditions by connecting an electrode belt without fur clipping. Material and methods: Fifteen pulmonary healthy dogs were anaesthetized, positioned in sternal recumbency and ventilated in a pressure-controlled mode at three different positive end-expiratory pressure levels (PEEP) of 0, 5 and 10 cmH(2)O for five breaths each, with a peak inspiratory pressure of 15 cmH(2)O. The impedance changes were recorded with a commercial EIT device applied around the thorax. Subsequently, the ventilation regime was repeated and a computed tomography scan (CT) of the same thoracic segment was performed for each PEEP level. The tidal volume (Vi) was recorded. For the collection of EIT data the sum of regional impedance changes was recorded. The impedance value of the entire lung (global) was recorded and the ventilated area was quartered into four regions of interest (ROI). In a CT image with the fewest adjacent organs, lung tissue was selected to obtain the mean value of lung radiodensitiy in Hounsfield-Units (HU) for the entire lung and for the four ROls. Results: EIT recordings via the electrode belt were possible without clipping. There was a significant correlation for the parameters of aeration as measured by EIT and CT for both the entire ventilated lung and the corresponding ROls. The increasing PEEP resulted in a proportional increase of the impedance, and there was a negative correlation between EIT and V-t. The better ventilated dorsal ROls could be identified using both EIT and CT. An intra-assay coefficient of variation showed a good reproducibility for lung ventilation in anaesthetized dogs in the EIT. Discussion: The results show that EIT is a reliable method for evaluating the ventilation of dogs in a clinical setting. The accuracy of EIT might be improved by using a mesh corresponding to the different thoracic shapes of the dogs.
引用
收藏
页码:15 / 21
页数:7
相关论文
共 50 条
  • [1] Lung Ventilation Functional Monitoring Based on Electrical Impedance Tomography
    陈晓艳
    王化祥
    赵波
    石小累
    Transactions of Tianjin University, 2009, 15 (01) : 7 - 12
  • [2] Lung Ventilation Functional Monitoring Based on Electrical Impedance Tomography
    陈晓艳
    王化祥
    赵波
    石小累
    Transactions of Tianjin University, 2009, (01) : 7 - 12
  • [3] Monitoring of regional lung ventilation using electrical impedance tomography
    Vasques, Francesco
    Sanderson, Barnaby
    Barrett, Nicholas A.
    Camporota, Luigi
    MINERVA ANESTESIOLOGICA, 2019, 85 (11) : 1231 - 1241
  • [4] Lung ventilation functional monitoring based on electrical impedance tomography
    Chen X.
    Wang H.
    Zhao B.
    Shi X.
    Transactions of Tianjin University, 2009, 15 (1) : 7 - 12
  • [5] Lung Ventilation Monitoring Incorporating Prior Information by Electrical Impedance Tomography
    Chen, Xiaoyan
    Wang, Huanxiang
    Shi, Xiaolei
    Yan, Yong
    Cui, Ziqiang
    2008 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2008, : 1531 - +
  • [6] Monitoring regional lung ventilation by functional electrical impedance tomography during assisted ventilation
    Frerichs, I
    Hahn, G
    Schiffmann, H
    Berger, C
    Hellige, G
    ELECTRICAL BIOIMPEDANCE METHODS: APPLICATIONS TO MEDICINE AND BIOTECHNOLOGY, 1999, 873 : 493 - 505
  • [7] Electrical Impedance Tomography: A Monitoring Tool for Ventilation-induced Lung Injury
    Fratti, Isabella
    Pozzi, Tommaso
    Hahn, Guenter
    Fioccola, Antonio
    Nicolardi, Rosmery V.
    Busana, Mattia
    Collino, Francesca
    Moerer, Onnen
    Camporota, Luigi
    Gattinoni, Luciano
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209 (12) : 1510 - 1513
  • [8] Monitoring of cardiac output and lung ventilation by electrical impedance tomography in a porcine model of acute lung injury
    Hochhausen, Nadine
    Dohmeier, Henriette
    Rossaint, Rolf
    Czaplik, Michael
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 352 - 355
  • [9] Monitoring of tidal ventilation by electrical impedance tomography in anaesthetised horses
    Mosing, M.
    Waldmann, A. D.
    Raisis, A.
    Boehm, S. H.
    Drynan, E.
    Wilson, K.
    EQUINE VETERINARY JOURNAL, 2019, 51 (02) : 222 - 226
  • [10] Electrical impedance tomography: the holy grail of ventilation and perfusion monitoring?
    Leonhardt, Steffen
    Lachmann, Burkhard
    INTENSIVE CARE MEDICINE, 2012, 38 (12) : 1917 - 1929