Electrical impedance tomography for lung ventilation monitoring of the dog

被引:6
|
作者
Gloning, Simon [1 ]
Pieper, Korbinian [1 ]
Zoeliner, Martin [1 ]
Meyer-Lindenberg, Andrea [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Clin Small Anim Surg & Reprod, Munich, Germany
来源
关键词
Lung function; general anaesthesia; positive end-expiratory pressure; COMPUTED-TOMOGRAPHY; CT; QUANTITATION; EMPHYSEMA; PERFUSION; SURGERY; DENSITY; INJURY;
D O I
10.15654/TPK-150569
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background: Electrical impedance tomography (EIT) is a radiation free technique which takes advantage of the different electrical conductivities of different tissues. Its main field of application is lung ventilation monitoring. The aim of this prospective study was to evaluate the feasibility of collecting EIT information on a sample of dogs with different thoracic shapes under clinical conditions by connecting an electrode belt without fur clipping. Material and methods: Fifteen pulmonary healthy dogs were anaesthetized, positioned in sternal recumbency and ventilated in a pressure-controlled mode at three different positive end-expiratory pressure levels (PEEP) of 0, 5 and 10 cmH(2)O for five breaths each, with a peak inspiratory pressure of 15 cmH(2)O. The impedance changes were recorded with a commercial EIT device applied around the thorax. Subsequently, the ventilation regime was repeated and a computed tomography scan (CT) of the same thoracic segment was performed for each PEEP level. The tidal volume (Vi) was recorded. For the collection of EIT data the sum of regional impedance changes was recorded. The impedance value of the entire lung (global) was recorded and the ventilated area was quartered into four regions of interest (ROI). In a CT image with the fewest adjacent organs, lung tissue was selected to obtain the mean value of lung radiodensitiy in Hounsfield-Units (HU) for the entire lung and for the four ROls. Results: EIT recordings via the electrode belt were possible without clipping. There was a significant correlation for the parameters of aeration as measured by EIT and CT for both the entire ventilated lung and the corresponding ROls. The increasing PEEP resulted in a proportional increase of the impedance, and there was a negative correlation between EIT and V-t. The better ventilated dorsal ROls could be identified using both EIT and CT. An intra-assay coefficient of variation showed a good reproducibility for lung ventilation in anaesthetized dogs in the EIT. Discussion: The results show that EIT is a reliable method for evaluating the ventilation of dogs in a clinical setting. The accuracy of EIT might be improved by using a mesh corresponding to the different thoracic shapes of the dogs.
引用
收藏
页码:15 / 21
页数:7
相关论文
共 50 条
  • [11] Electrical impedance tomography: the holy grail of ventilation and perfusion monitoring?
    Steffen Leonhardt
    Burkhard Lachmann
    Intensive Care Medicine, 2012, 38 : 1917 - 1929
  • [12] Feature Extraction of Lung Ventilation by Biomedical Electrical Impedance Tomography
    Chen, Xiaoyan
    Chang, Xiaomin
    2017 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST), 2017, : 558 - 562
  • [13] Electrical impedance tomography in monitoring experimental lung injury
    I. Frerichs
    G. Hahn
    T. Schröder
    G. Heilige
    Intensive Care Medicine, 1998, 24 : 829 - 836
  • [14] The Research Progress of Electrical Impedance Tomography for Lung Monitoring
    Shi, Yan
    Yang, ZhiGuo
    Xie, Fei
    Ren, Shuai
    Xu, ShaoFeng
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [15] Monitoring of lung volume in dogs with electrical impedance tomography
    Adler, A
    Shinozuka, N
    Guardo, R
    Berthiaume, Y
    Bates, J
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 776 - 777
  • [16] Electrical impedance tomography in monitoring experimental lung injury
    Frerichs, I
    Hahn, G
    Schroder, T
    Hellige, G
    INTENSIVE CARE MEDICINE, 1998, 24 (08) : 829 - 836
  • [17] Ventilation monitoring by impedance tomography
    Hermosa, C.
    Calvo, E.
    Gordo, F.
    MEDICINA INTENSIVA, 2014, 38 (04) : 270 - 270
  • [18] The Dark Side of the Lung Unveiling Regional Lung Ventilation with Electrical Impedance Tomography
    Canet, Jaume
    Gallart, Lluis
    ANESTHESIOLOGY, 2012, 116 (06) : 1186 - 1188
  • [19] Wearable 3D Lung Ventilation Monitoring System with Multi Frequency Electrical Impedance Tomography
    Kim, Minseo
    Bae, Joonsung
    Yoo, Hoi-Jun
    2017 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2017,
  • [20] Monitoring of Regional Lung Ventilation Using Electrical Impedance Tomography After Cardiac Surgery in Infants and Children
    Ulrich Krause
    Kristin Becker
    Günter Hahn
    Jörg Dittmar
    Wolfgang Ruschewski
    Thomas Paul
    Pediatric Cardiology, 2014, 35 : 990 - 997