Axial Length Measurement Failure Rates with the IOLMaster and Lenstar LS 900 in Eyes with Cataract

被引:43
|
作者
McAlinden, Colm [1 ,3 ]
Wang, Qinmei [1 ,2 ]
Pesudovs, Konrad [3 ]
Yang, Xin [1 ]
Bao, Fangjun [1 ,2 ]
Yu, Ayong [1 ,2 ]
Lin, Shishi [1 ]
Feng, Yifan [1 ]
Huang, Jinhai [1 ,2 ]
机构
[1] Wenzhou Med Univ, Sch Ophthalmol & Optometry, Wenzhou, Zhejiang, Peoples R China
[2] Minist Hlth PR China, Key Lab Vis Sci, Wenzhou, Zhejiang, Peoples R China
[3] Flinders Univ S Australia, Adelaide, SA 5001, Australia
来源
PLOS ONE | 2015年 / 10卷 / 06期
关键词
PARTIAL COHERENCE INTERFEROMETRY; INTRAOCULAR-LENS; POWER CALCULATION; OPTICAL BIOMETRY; APPLANATION ULTRASOUND; OCULAR BIOMETRY; REFLECTOMETRY; REPEATABILITY; AGREEMENT; SURGERY;
D O I
10.1371/journal.pone.0128929
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To evaluate axial length (AL) measurement failure rate with the IOLMaster (Carl Zeiss AG, Germany) and Lenstar LS 900 (Haag-Streit AG, Switzerland) in eyes with cataract. Methods Two hundred and ninety-six eyes of 170 patients with cataract were enrolled. Cataract type and severity were graded using the Lens Opacities Classification System III (LOCS III) and AL measurements were attempted with IOLMaster (version 5.4) and Lenstar LS 900 (version 1.1). Chi-squared analysis was used to assess if the difference in AL measurement acquisition rate was statistically significant between the two devices. The association of the different cataract types and severity with the AL measurement acquisition rate was evaluated with logistic regression analysis. Results AL measurements were obtained in 184 eyes (62.16%) using the IOLMaster and 191 eyes (64.53%) using the Lenstar, which corresponds to a failure rate of 37.84% and 35.47% respectively. Chi-square analysis indicated no significant difference between the Lenstar and IOLMaster for AL measurement failure rate (x(2) = 0.356, P = 0.550). Logistic regression analysis indicated no association between acquisition rates and cortical or nuclear cataracts with either device. There was a statistically significant association between acquisition rates and increasing severity of posterior subcapsular cataracts with the IOLMaster (beta = -1.491, P<0.001) and Lenstar LS 900 (beta= -1.507, P<0.001). Conclusion The IOLMaster and Lenstar LS 900 have similar AL measurement failure rates (35-38%) for Chinese public hospital cataract patients. Increasing severity of posterior subcapsular cataracts was problematic for both devices.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Comparison of pupil diameter measurement with Lenstar LS 900 and OPD Scan II. Not interchangeable devices
    Gedik, Sansal
    Koktekir, Bengu E.
    Bakbak, Berker
    Gonul, Saban
    SAUDI MEDICAL JOURNAL, 2012, 33 (11) : 1239 - 1240
  • [22] Axial length measurement failure rates using optical biometry based on swept-source OCT in cataractous eyes
    Tana-Rivero, Pedro
    Tana-Sanz, Santiago
    Pastor-Pascual, Francisco
    Ruiz-Mesa, Ramon
    Montes-Mico, Robert
    EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (08) : 633 - 640
  • [23] Keratometry ad Axial Length of Microphthalmic Eyes With Pediatric Cataract
    Morini, C.
    Capozzi, P.
    Vadala, P.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [24] Lenstar LS900、IOLMaster与A超测量白内障患者人工晶状体度数的对比研究
    王峥
    郑帆
    吴文凌
    叶向彧
    福建医药杂志, 2012, 34 (01) : 115 - 117
  • [25] Slit-lamp measurement of anterior chamber depth and its agreement with anterior segment optical coherence tomography and Lenstar LS 900 in pseudoexfoliation and normal eyes
    Ray, Vanita Pathak
    Ramesh, Smitha B.
    Rathi, Varsha
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (09) : 2469 - 2474
  • [26] Lenstar LS900与IOLMaster测量眼前节生物参数及人工晶状体度数的比较
    叶向彧
    纪建丽
    张广斌
    王乐
    毛益辉
    何雪洪
    眼科新进展, 2011, 31 (11) : 1039 - 1041+1045
  • [27] The measurement of anterior chamber depth and axial length with the IOLMaster compared with contact ultrasonic axial scan
    Bai, Quan-Hao
    Wang, Jun-Li
    Wang, Qing-Qiang
    Yan, Qi-Chang
    Zhang, Jin-Song
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2008, 1 (02) : 151 - 154
  • [28] Ultrasound axial length measurement in biphakic eyes
    Hoffer, KJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (05): : 961 - 965
  • [29] Assessing IOLMaster Measurement of Eye Axial Length in Pathologic Myopia Patients with Staphyloma
    Leong, Jamie
    Silverman, Ronald
    Chang, Stanley
    Quan Hoang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [30] Intralocular lens power calculation using the IOLMaster and various formulas in eyes with long axial length
    Wang, Jia-Kang
    Hu, Chao-Yu
    Chang, Shu-Wen
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (02): : 262 - 267