Axial Length Measurement Failure Rates with the IOLMaster and Lenstar LS 900 in Eyes with Cataract

被引:43
|
作者
McAlinden, Colm [1 ,3 ]
Wang, Qinmei [1 ,2 ]
Pesudovs, Konrad [3 ]
Yang, Xin [1 ]
Bao, Fangjun [1 ,2 ]
Yu, Ayong [1 ,2 ]
Lin, Shishi [1 ]
Feng, Yifan [1 ]
Huang, Jinhai [1 ,2 ]
机构
[1] Wenzhou Med Univ, Sch Ophthalmol & Optometry, Wenzhou, Zhejiang, Peoples R China
[2] Minist Hlth PR China, Key Lab Vis Sci, Wenzhou, Zhejiang, Peoples R China
[3] Flinders Univ S Australia, Adelaide, SA 5001, Australia
来源
PLOS ONE | 2015年 / 10卷 / 06期
关键词
PARTIAL COHERENCE INTERFEROMETRY; INTRAOCULAR-LENS; POWER CALCULATION; OPTICAL BIOMETRY; APPLANATION ULTRASOUND; OCULAR BIOMETRY; REFLECTOMETRY; REPEATABILITY; AGREEMENT; SURGERY;
D O I
10.1371/journal.pone.0128929
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To evaluate axial length (AL) measurement failure rate with the IOLMaster (Carl Zeiss AG, Germany) and Lenstar LS 900 (Haag-Streit AG, Switzerland) in eyes with cataract. Methods Two hundred and ninety-six eyes of 170 patients with cataract were enrolled. Cataract type and severity were graded using the Lens Opacities Classification System III (LOCS III) and AL measurements were attempted with IOLMaster (version 5.4) and Lenstar LS 900 (version 1.1). Chi-squared analysis was used to assess if the difference in AL measurement acquisition rate was statistically significant between the two devices. The association of the different cataract types and severity with the AL measurement acquisition rate was evaluated with logistic regression analysis. Results AL measurements were obtained in 184 eyes (62.16%) using the IOLMaster and 191 eyes (64.53%) using the Lenstar, which corresponds to a failure rate of 37.84% and 35.47% respectively. Chi-square analysis indicated no significant difference between the Lenstar and IOLMaster for AL measurement failure rate (x(2) = 0.356, P = 0.550). Logistic regression analysis indicated no association between acquisition rates and cortical or nuclear cataracts with either device. There was a statistically significant association between acquisition rates and increasing severity of posterior subcapsular cataracts with the IOLMaster (beta = -1.491, P<0.001) and Lenstar LS 900 (beta= -1.507, P<0.001). Conclusion The IOLMaster and Lenstar LS 900 have similar AL measurement failure rates (35-38%) for Chinese public hospital cataract patients. Increasing severity of posterior subcapsular cataracts was problematic for both devices.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Assessment of a new averaging algorithm to increase the sensitivity of axial eye length measurement with optical biometry in eyes with dense cataract
    Hirnschall, Nino
    Murphy, Sinead
    Pimenides, Dimitris
    Maurino, Vincenzo
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (01): : 45 - 49
  • [42] Novel MRI Algorithm Pipeline Suggests Overestimation of Axial Length on IOLMaster Compared to Measurement on MRI
    Vu, Alexander H.
    Grinband, Lack
    Xing, Albert
    Hoang, Quan V.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [43] Effect of age at time of cataract surgery on subsequent axial length growth in infant eyes
    Griener, ED
    Dahan, E
    Lambert, SR
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (09): : 1209 - 1213
  • [44] Comparative analysis of axial length measurement method for eyes with submacular hemorrhage
    Nagayama, Masakazu
    Kimura, Shuhei
    Hosokawa, Mio Morizane
    Shiode, Yusuke
    Matoba, Ryo
    Morita, Tetsuro
    Kanenaga, Keisuke
    Morizane, Yuki
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2025, : 196 - 202
  • [45] Accuracy and reproducibility of axial length measurement in eyes with silicone oil endotamponade
    Roessler, G. F.
    Huth, J. K.
    Dietlein, T. S.
    Dinslage, S.
    Plange, N.
    Walter, P.
    Mazinani, B. A. E.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (11) : 1492 - 1494
  • [46] Comparison of axial length, anterior chamber depth and intraocular lens power between IOLMaster and ultrasound in normal, long and short eyes
    Dong, Jing
    Zhang, Yaqin
    Zhang, Haining
    Jia, Zhijie
    Zhang, Suhua
    Wang, Xiaogang
    PLOS ONE, 2018, 13 (03):
  • [47] Eyes of Aniso-Axial Length Individuals Share Generally Similar Corneal Biometrics with Normal Eyes in Cataract Population
    Zhang, Min
    Chen, Tianhui
    Deng, Michael
    Chen, Jiahui
    Jing, Qinghe
    Jiang, Yongxiang
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [48] 光学相干生物测量仪Lenstar LS 900与IOLMaster对眼球生物学参数测量的一致性评价
    沈沛阳
    丁小虎
    何明光
    钟兴武
    陈海波
    邢健强
    眼科新进展, 2014, 34 (06) : 560 - 563
  • [49] Axial length of cataract eyes: a comparison of two cohorts over a span of 10 years apart
    Yu-Ting Hsiao
    Po-Chiung Fang
    Pei-Chang Wu
    Ming-Tse Kuo
    Yi-Hao Chen
    Hsi-Kung Kuo
    BMC Ophthalmology, 21
  • [50] Axial length of cataract eyes: a comparison of two cohorts over a span of 10 years apart
    Hsiao, Yu-Ting
    Fang, Po-Chiung
    Wu, Pei-Chang
    Kuo, Ming-Tse
    Chen, Yi-Hao
    Kuo, Hsi-Kung
    BMC OPHTHALMOLOGY, 2021, 21 (01)