Mangafodipir trisodium injection, a new contrast medium for magnetic resonance imaging: Detection and quantitation of the parent compound MnDPDP and metabolites in human plasma by high performance liquid chromatography

被引:10
|
作者
Toft, KG
Friisk, GA
Skotland, T
机构
[1] Nycomed Imaging AS, Research and Development, N-0401 Oslo
关键词
HPLC; mixed-bed resin; mangafodipir trisodium; MnDPDP; plasma;
D O I
10.1016/S0731-7085(96)01945-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Manganese(II) dipyridoxpl diphosphate (MnDPDP) is the active component of mangafodipir trisodium injection (Teslascan(R)); a new contrast medium for magnetic resonance imaging. A high performance liquid chromatography (HPLC) method was developed for the simultaneous determination of MnDPDP and its five major metabolites in human plasma, i.e. the dephosphorylation products MnDPMP (manganese(II) dipyridoxyl monophosphate) and MnPLED (manganese(II) dipyridoxyl ethylenediamine diacetate) and the corresponding substances obtained after transmetallation with zinc (ZnDPDP, ZnDPMP and ZnPLED). Heparinized blood samples from patients receiving mangafodipir trisodium injection were immediately mixed with solid trisodium phosphate dodecahydrate to obtain pH 10.0 +/- 0.2 in order to inhibit further in vitro dephosphorylation and transmetallation. The plasma thus obtained was ultrafiltrated prior to HPLC analysis, The chromatographic separation was obtained using a mixed-bed resin with both anion exchange and reversed-phase functions (OmniPac(TM) PAX-500) using isocratic elution and UV detection at 310 nm. With an injection volume of 50 mu l, the limit of quantitation (LOQ) values were 0.8-2.3 mu M for the Mn compounds and 0.1-0.8 mu M for the Zn compounds. The between-run accuracy of spiked plasma samples was in the range 97.5-106.7% with a precision in the range 3.1-9.0%. The best fit calibration curves were obtained using non-linear regression according to the equation Y = A + BXM in the concentration range from LOQ to 100 mu M. Long-term storage of spiked plasma samples for three months at - 20 degrees C demonstrated the required stability with recovery values within 85-115% of MnDPDP and its five metabolites. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:973 / 981
页数:9
相关论文
共 50 条
  • [41] DETERMINATION OF CODEINE AND ITS METABOLITES IN HUMAN-BLOOD PLASMA AND IN MICROSOMAL INCUBATES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION
    PERSSON, K
    LINDSTROM, B
    SPALDING, D
    WAHLSTROM, A
    RANE, A
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 491 (02): : 473 - 480
  • [42] Determination of clozapine and its major metabolites in human plasma and red blood cells by high-performance liquid chromatography with ultraviolet absorbance detection
    Guitton, C
    Kinowski, JM
    Aznar, R
    Bressolle, F
    JOURNAL OF CHROMATOGRAPHY B, 1997, 690 (1-2): : 211 - 222
  • [43] Optimizing high-performance liquid chromatography method with fluorescence detection for quantification of tamoxifen and two metabolites in human plasma: Application to a clinical study
    Zhu, Yu-Bing
    Zhang, Qian
    Zou, Jian-Jun
    Yu, Cui-Xia
    Xiao, Da-Wei
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 46 (02) : 349 - 355
  • [44] Quantitation of niflumic acid in human plasma by high-performance liquid chromatography with ultraviolet absorbance detection and its application to a bioequivalence study of talniflumate tablets
    Lee, HW
    Won, KJ
    Cho, SH
    Ha, YH
    Park, WS
    Yim, HT
    Baek, A
    Rew, JH
    Yoon, SH
    Yim, SV
    Chung, JH
    Lee, KT
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 821 (02): : 215 - 220
  • [45] The quantitative analysis of heroin, methadone and their metabolites and the simultaneous detection of cocaine, acetylcodeine and their metabolites in human plasma by high-performance liquid chromatography coupled with tandem mass spectrometry
    Rook, EJ
    Hillebrand, MJX
    Rosing, H
    van Ree, JM
    Beijnen, JH
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 824 (1-2): : 213 - 221
  • [46] Quantitation of psilocin in human plasma by high-performance liquid chromatography and electrochemical detection:: comparison of liquid-liquid extraction with automated on-line solid-phase extraction
    Lindenblatt, H
    Krämer, E
    Holzmann-Erens, P
    Gouzoulis-Mayfrank, E
    Kovar, KA
    JOURNAL OF CHROMATOGRAPHY B, 1998, 709 (02): : 255 - 263
  • [47] Determination of a new oral cephalosporin, S-1090, in human plasma and urine by direct injection high-performance liquid chromatography with ultraviolet detection and column switching
    Fujitomo, H
    Nagaoka, T
    Nishino, I
    Umeda, T
    JOURNAL OF CHROMATOGRAPHY B, 1999, 728 (01): : 125 - 131
  • [48] Determination of cilnidipine, a new calcium antagonist, in human plasma using high performance liquid chromatography with tandem mass spectrometric detection
    Zhang, Xianhua
    Zhai, Suodi
    Zhao, Rongsheny
    Jin Ouyang
    Li, Xiaoquang
    Baeyens, Willy R. G.
    ANALYTICA CHIMICA ACTA, 2007, 600 (1-2) : 142 - 146
  • [49] CONFIRMATION OF CANNABIS USE .3. SIMULTANEOUS QUANTITATION OF 6 METABOLITES OF DELTA-9-TETRAHYDROCANNABINOL IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    NAKAHARA, Y
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 434 (01): : 247 - 252
  • [50] On-line coupling of automated solid-phase extraction with high-performance liquid chromatography and electrochemical detection -: Quantitation of oxidizable drugs of abuse and their metabolites in plasma and urine
    Krämer, E
    Kovar, KA
    JOURNAL OF CHROMATOGRAPHY B, 1999, 731 (02): : 167 - 177