Mangafodipir trisodium injection, a new contrast medium for magnetic resonance imaging: Detection and quantitation of the parent compound MnDPDP and metabolites in human plasma by high performance liquid chromatography

被引:10
|
作者
Toft, KG
Friisk, GA
Skotland, T
机构
[1] Nycomed Imaging AS, Research and Development, N-0401 Oslo
关键词
HPLC; mixed-bed resin; mangafodipir trisodium; MnDPDP; plasma;
D O I
10.1016/S0731-7085(96)01945-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Manganese(II) dipyridoxpl diphosphate (MnDPDP) is the active component of mangafodipir trisodium injection (Teslascan(R)); a new contrast medium for magnetic resonance imaging. A high performance liquid chromatography (HPLC) method was developed for the simultaneous determination of MnDPDP and its five major metabolites in human plasma, i.e. the dephosphorylation products MnDPMP (manganese(II) dipyridoxyl monophosphate) and MnPLED (manganese(II) dipyridoxyl ethylenediamine diacetate) and the corresponding substances obtained after transmetallation with zinc (ZnDPDP, ZnDPMP and ZnPLED). Heparinized blood samples from patients receiving mangafodipir trisodium injection were immediately mixed with solid trisodium phosphate dodecahydrate to obtain pH 10.0 +/- 0.2 in order to inhibit further in vitro dephosphorylation and transmetallation. The plasma thus obtained was ultrafiltrated prior to HPLC analysis, The chromatographic separation was obtained using a mixed-bed resin with both anion exchange and reversed-phase functions (OmniPac(TM) PAX-500) using isocratic elution and UV detection at 310 nm. With an injection volume of 50 mu l, the limit of quantitation (LOQ) values were 0.8-2.3 mu M for the Mn compounds and 0.1-0.8 mu M for the Zn compounds. The between-run accuracy of spiked plasma samples was in the range 97.5-106.7% with a precision in the range 3.1-9.0%. The best fit calibration curves were obtained using non-linear regression according to the equation Y = A + BXM in the concentration range from LOQ to 100 mu M. Long-term storage of spiked plasma samples for three months at - 20 degrees C demonstrated the required stability with recovery values within 85-115% of MnDPDP and its five metabolites. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:973 / 981
页数:9
相关论文
共 50 条
  • [31] Assay for quantitation of clozapine and its metabolite N-desmethylclozapine in human plasma by high-performance liquid chromatography with ultraviolet detection
    Edno, L
    Combourieu, I
    Cazenave, M
    Tignol, J
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 16 (02) : 311 - 318
  • [32] New sensitive assay of vancomycin in human plasma using high-performance liquid chromatography and electrochemical detection
    Favetta, P
    Guitton, J
    Bleyzac, N
    Dufresne, C
    Bureau, J
    JOURNAL OF CHROMATOGRAPHY B, 2001, 751 (02): : 377 - 382
  • [33] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY OF THE MAGNETIC-RESONANCE-IMAGING CONTRAST AGENT GADOBENATE IN PLASMA, URINE AND BILE
    LORUSSO, V
    POGGESI, I
    ARBUGHI, T
    DALFIUME, D
    TIRONE, P
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 656 (02): : 415 - 422
  • [34] Quantitation of atorvastatin in human plasma using directly suspended acceptor droplet in liquid-liquid-liquid microextraction and high-performance liquid chromatography-ultraviolet detection
    Farahani, Hadi
    Norouzi, Parviz
    Beheshti, Abolghasem
    Sobhi, Hamid Reza
    Dinarvand, Rasoul
    Ganjali, Mohammad Reza
    TALANTA, 2009, 80 (02) : 1001 - 1006
  • [35] QUANTITATION OF THE NEW HYPOGLYCEMIC AGENT AG-EE 388-ZW IN HUMAN PLASMA BY AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    GREISCHEL, A
    BESCHKE, K
    RAPP, H
    ROTH, W
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 568 (01): : 246 - 252
  • [36] Determination of metoprolol and its two metabolites in human plasma and urine by high performance liquid chromatography with fluorescence detection and its application in pharmacokinetics
    Xu, Tao
    Bao, Shihui
    Geng, Peiwu
    Luo, Jun
    Yu, Lei
    Pan, Peipei
    Chen, Yi
    Hu, Guoxin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 937 : 60 - 66
  • [37] A NOVEL METHOD FOR THE QUANTITATION OF 6-MERCAPTOPURINE IN HUMAN-PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    BURTON, NK
    AHERNE, GW
    MARKS, V
    JOURNAL OF CHROMATOGRAPHY, 1984, 309 (02): : 409 - 414
  • [38] SIMULTANEOUS DETERMINATION OF CITALOPRAM AND ITS METABOLITES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING AND FLUORESCENCE DETECTION BY DIRECT PLASMA INJECTION
    MATSUI, E
    HOSHINO, M
    MATSUI, A
    OKAHIRA, A
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 668 (02): : 299 - 307
  • [39] High-performance liquid chromatographic determination of the magnetic resonance imaging contrast agent gadobenate ion in plasma, urine, faeces, bile and tissues
    Arbughi, T
    Bertani, F
    Celeste, R
    Grotti, A
    Sillari, S
    Tirone, P
    JOURNAL OF CHROMATOGRAPHY B, 1998, 713 (02): : 415 - 426
  • [40] DETERMINATION OF DICLOFENSINE, AN ANTIDEPRESSANT AGENT, AND ITS MAJOR METABOLITES IN HUMAN-PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUOROMETRIC DETECTION
    STROJNY, N
    DESILVA, JAF
    JOURNAL OF CHROMATOGRAPHY, 1985, 341 (02): : 313 - 331