The quantitative analysis of heroin, methadone and their metabolites and the simultaneous detection of cocaine, acetylcodeine and their metabolites in human plasma by high-performance liquid chromatography coupled with tandem mass spectrometry

被引:111
|
作者
Rook, EJ
Hillebrand, MJX
Rosing, H
van Ree, JM
Beijnen, JH
机构
[1] Slotervaart Hosp, Dept Pharm & Pharmacol, NL-1006 BK Amsterdam, Netherlands
[2] Cent Comm Treatment Heroin Addicts, Utrecht, Netherlands
[3] Univ Utrecht, Rudolf Magnus Inst Neurosci, Dept Pharmacol & Anat, Med Ctr, Utrecht, Netherlands
[4] Univ Utrecht, Fac Pharmaceut Sci, Utrecht, Netherlands
关键词
heroin; acetylcodeine; cocaine; methadone; LC-MS-MS;
D O I
10.1016/j.jchromb.2005.05.048
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
For a pharmacokinetic-pharmacodynamic study in opioid tolerant patients, who were treated with heroin in combination with methadone, a liquid chromatographic assay with tandem mass spectrometry detection (LC-MS/MS) was developed for the simultaneous determination of heroin, methadone, heroin metabolites 6-monoacetylmorphine, morphine, and morphine-6 and 3-glucuronide and methadone metabolite EMDP. To detect any abuse of substances besides the prescribed opioids the assay was extended with the detection of cocaine, its metabolites benzoylecgonine and norcocaine and illicit heroin adulterants acetylcodeine and codeine. Heroin-d6, morphine-d3, morphine-3-glucuronide-d3 and methadone-d9 were used as internal standards. The sample pre-treatment consisted of solid phase extraction using mixed mode sorbent columns (MCX Oasis). Chromatographic separation was performed at 25 degrees C on a reversed phase Zorbax column with a gradient mobile phase consisting of ammonium formate (pH 4.0) and acetonitrile. The run time was 15 min. MS with relatively mild electrospray ionisation under atmospheric pressure was applied. The triple quadrupole MS was operating in the positive ion mode and multiple reaction monitoring (MRM) was used for drug quantification. The method was validated over a concentration range of 5-500 ng/mL for all analytes. The total recovery of heroin varied between 86 and 96% and of the heroin metabolites between 76 and 101%. lntra-assay and inter-assay accuracy and precision of all analytes were always within the designated limits (<= 20% at lower limit of quantification (LLQ) and <= 15% for other samples). This specific and sensitive assay was successfully applied in pharmacokinetic studies with medically prescribed heroin and toxicological cases. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:213 / 221
页数:9
相关论文
共 50 条
  • [1] Quantitative analysis of cocaine and its metabolites in whole blood and urine by high-performance liquid chromatography coupled with tandem mass spectrometry
    Johansen, Sys Stybe
    Bhatia, Helle Merete
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 338 - 344
  • [2] Simultaneous determination of cyadox and its metabolites in plasma by high-performance liquid chromatography tandem mass spectrometry
    He, Limin
    Liu, Kaiyong
    Su, Yijuan
    Zhang, Jiahui
    Liu, Yahong
    Zeng, Zhenling
    Fang, Binghu
    Zhang, Guijun
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (15) : 1755 - 1762
  • [3] Simultaneous analysis of buprenorphine, methadone, cocaine, opiates and nicotine metabolites in sweat by liquid chromatography tandem mass spectrometry
    Marta Concheiro
    Diaa M. Shakleya
    Marilyn A. Huestis
    Analytical and Bioanalytical Chemistry, 2011, 400 : 69 - 78
  • [4] Simultaneous analysis of buprenorphine, methadone, cocaine, opiates and nicotine metabolites in sweat by liquid chromatography tandem mass spectrometry
    Concheiro, Marta
    Shakleya, Diaa M.
    Huestis, Marilyn A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (01) : 69 - 78
  • [5] Analysis of nitrofuran metabolites in food by high-performance liquid chromatography with tandem mass spectrometry detection
    Edder, P
    Vargas, S
    Ortelli, D
    Corvi, C
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, 41 (12) : 1608 - 1614
  • [6] Simultaneous analysis of flunitrazepam and its major metabolites in human plasma by high performance liquid chromatography tandem mass spectrometry
    Kollroser, M
    Schober, C
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 28 (06) : 1173 - 1182
  • [7] Simultaneous determination of Aprepitant and two metabolites in human plasma by high-performance liquid chromatography with tandem mass spectrometric detection
    Chavez-Eng, CM
    Constanzer, ML
    Matuszewski, BK
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 35 (05) : 1213 - 1229
  • [8] Simultaneous determination of glimepiride and its metabolites in human plasma by liquid chromatography coupled to a tandem mass spectrometry
    Kyeumhan Noh
    Eunyoung Kim
    Taecheon Jeong
    MinKyun Na
    Moon-Chang Baek
    Kwang-Hyeon Liu
    Pil-Hoon Park
    Beom Soo Shin
    Wonku Kang
    Archives of Pharmacal Research, 2011, 34 : 2073 - 2078
  • [9] Simultaneous Determination of Glimepiride and its Metabolites in Human Plasma by Liquid Chromatography Coupled to a Tandem Mass Spectrometry
    Noh, Kyeumhan
    Kim, Eunyoung
    Jeong, Taecheon
    Na, MinKyun
    Baek, Moon-Chang
    Liu, Kwang-Hyeon
    Park, Pil-Hoon
    Shin, Beom Soo
    Kang, Wonku
    ARCHIVES OF PHARMACAL RESEARCH, 2011, 34 (12) : 2073 - 2078
  • [10] Quantitative determination of active racecadotril metabolites in human plasma with high performance liquid chromatography tandem mass spectrometry
    Zhong Jia-Qing
    Qin Yong-Pin
    Yu Qin
    Zheng Wei
    Liang Mao-Zhi
    Nan Feng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (01) : 91 - 94