Mangafodipir trisodium injection, a new contrast medium for magnetic resonance imaging: Detection and quantitation of the parent compound MnDPDP and metabolites in human plasma by high performance liquid chromatography

被引:10
|
作者
Toft, KG
Friisk, GA
Skotland, T
机构
[1] Nycomed Imaging AS, Research and Development, N-0401 Oslo
关键词
HPLC; mixed-bed resin; mangafodipir trisodium; MnDPDP; plasma;
D O I
10.1016/S0731-7085(96)01945-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Manganese(II) dipyridoxpl diphosphate (MnDPDP) is the active component of mangafodipir trisodium injection (Teslascan(R)); a new contrast medium for magnetic resonance imaging. A high performance liquid chromatography (HPLC) method was developed for the simultaneous determination of MnDPDP and its five major metabolites in human plasma, i.e. the dephosphorylation products MnDPMP (manganese(II) dipyridoxyl monophosphate) and MnPLED (manganese(II) dipyridoxyl ethylenediamine diacetate) and the corresponding substances obtained after transmetallation with zinc (ZnDPDP, ZnDPMP and ZnPLED). Heparinized blood samples from patients receiving mangafodipir trisodium injection were immediately mixed with solid trisodium phosphate dodecahydrate to obtain pH 10.0 +/- 0.2 in order to inhibit further in vitro dephosphorylation and transmetallation. The plasma thus obtained was ultrafiltrated prior to HPLC analysis, The chromatographic separation was obtained using a mixed-bed resin with both anion exchange and reversed-phase functions (OmniPac(TM) PAX-500) using isocratic elution and UV detection at 310 nm. With an injection volume of 50 mu l, the limit of quantitation (LOQ) values were 0.8-2.3 mu M for the Mn compounds and 0.1-0.8 mu M for the Zn compounds. The between-run accuracy of spiked plasma samples was in the range 97.5-106.7% with a precision in the range 3.1-9.0%. The best fit calibration curves were obtained using non-linear regression according to the equation Y = A + BXM in the concentration range from LOQ to 100 mu M. Long-term storage of spiked plasma samples for three months at - 20 degrees C demonstrated the required stability with recovery values within 85-115% of MnDPDP and its five metabolites. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:973 / 981
页数:9
相关论文
共 50 条
  • [1] Metabolism of mangafodipir trisodium (MnDPDP), a new contrast medium for magnetic resonance imaging, in beagle dogs
    Toft, KG
    Hustvedt, SO
    Grant, D
    Friisk, GA
    Skotland, T
    EUROPEAN JOURNAL OF DRUG METABOLISM AND PHARMACOKINETICS, 1997, 22 (01) : 65 - 72
  • [2] Metabolism of mangafodipir trisodium (MnDPDP), a new contrast medium for magnetic resonance imaging, in beagle dogs
    K. G. Toft
    S. O. Hustvedt
    D. Grant
    G. A. Friisk
    T. Skotland
    European Journal of Drug Metabolism and Pharmacokinetics, 1997, 22 : 65 - 72
  • [3] Mangafodipir trisodium injection, a new contrast medium for magnetic resonance imaging: In vitro metabolism and protein binding studies of the active component MnDPDP in human blood
    Toft, KG
    Kindberg, GM
    Skotland, T
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (07) : 983 - 988
  • [4] Quantitation of trans-resveratrol and detection of its metabolites in human plasma and urine by high performance liquid chromatography
    Boocock, David J.
    Patel, Ketan R.
    Faust, Guy E. S.
    Normolle, Daniel P.
    Marczylo, Timothy H.
    Crowell, James A.
    Brenner, Dean E.
    Booth, Tristan D.
    Gescher, Andreas
    Steward, William P.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 848 (02): : 182 - 187
  • [5] Quantitation of Venetoclax in Human Plasma by High-Performance Liquid Chromatography with Ultraviolet Detection
    Fukuda, Natsuki
    Kobayashi, Takahiro
    Sato, Honami
    Akamine, Yumiko
    Takahashi, Naoto
    Miura, Masatomo
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2024, 62 (01) : 58 - 64
  • [6] Simultaneous and rapid quantitation of benazepril and benazeprilat in human plasma by high performance liquid chromatography with ultraviolet detection
    Wang, Xue-Ding
    Chan, Eli
    Chen, Xiao
    Liao, Xiao-Xing
    Tang, Cheng
    Zhou, Zhi-Wei
    Huang, Min
    Zhou, Shu-Feng
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (01) : 224 - 230
  • [7] Quantitation of zopiclone and desmethylzopiclone in human plasma by high-performance liquid chromatography using fluorescence detection
    Nirogi, Ramakrishna V. S.
    Kandikere, Vishwottam N.
    Mudigonda, Koteshwara
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (08) : 794 - 799
  • [8] QUANTITATION OF OXYCODONE IN HUMAN PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    SMITH, MT
    WATT, JA
    MAPP, GP
    CRAMOND, T
    THERAPEUTIC DRUG MONITORING, 1991, 13 (02) : 126 - 130
  • [9] Quantitation of a new macrolide in plasma by high performance liquid chromatography with tandem mass spectrometric detection: Comparison with electrochemical detection
    Daszkowski, DJ
    Ong, VS
    Menacherry, S
    El-Shourbagy, T
    Carroll, SL
    Marsh, KC
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1999, 22 (05) : 641 - 657
  • [10] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ELECTROCHEMICAL DETECTION OF VECURONIUM AND ITS METABOLITES IN HUMAN PLASMA
    DUCHARME, J
    VARIN, F
    BEVAN, DR
    DONATI, F
    THEORET, Y
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 573 (01): : 79 - 86