Screening of abnormal LiF:Mg,Cu,P glow curves

被引:1
|
作者
Bautro, N
Cassata, J
Rotunda, JE
机构
[1] John R Marsh Canc Ctr, Hagerstown, MD 21742 USA
[2] USN, Dosimetry Ctr, Bethesda, MD 20889 USA
[3] St Gobain Ind Ceram Inc, Biocron NE Div, Solon, OH 44139 USA
关键词
D O I
10.1093/oxfordjournals.rpd.a032762
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A process to screen electronically abnormal LiF:Mg,Cu,P glow curves in routine dosimetry is proposed. The method is based on the fact that when a glow curve is normalised to a part of the integral of the glow curve it loses its dependence on the magnitude of the exposure. This characteristic allows a glow curve from a dosemeter exposed in the field to be compared with an 'ideal' glow curve from the same dosemeter. A difference curve is generated from the differences between the normalised 'ideal' and the normalised field curves. This difference curve can be used to identify the abnormal characteristics of the field-generated glow curve and, since both normalised curves are essentially the same, the anomalies can be resolved by reconstructing the field curve to match the 'ideal' curve.
引用
收藏
页码:387 / 391
页数:5
相关论文
共 50 条
  • [31] Optical absorption in LiF, LiF:Mg, LiF:Mg,Cu,P irradiated with high gamma and beta doses
    Remy, K.
    Sholom, S.
    Obryk, B.
    McKeever, S. W. S.
    RADIATION MEASUREMENTS, 2017, 106 : 113 - 117
  • [32] Recent improvements in LiF:Mg,Ti and LiF:Mg,Cu,P based environmental dosimetry
    Delgado, A
    RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 129 - 134
  • [33] Comparison of the effects of exposure to light in Harshaw LiF:Mg,Ti and LiF:Mg,Cu,P
    Baker, S. T.
    Gilvin, P. J.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 258 - 260
  • [34] Evaluating two extremity dosemeters based on LiF:Mg,Ti or LiF:Mg,Cu,P
    Luo, LZ
    Velbeck, KJ
    Rotunda, JE
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 211 - 216
  • [35] Evaluating two extremity dosemeters based on LiF:Mg,Ti or LiF:Mg,Cu,P
    Luo, LZ
    Velbeck, KJ
    Rotunda, JE
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A211 - A216
  • [36] Role of impurities in the thermoluminescence of LiF:Mg,Cu,P
    Chen, TC
    Stoebe, TG
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 243 - 246
  • [37] Low temperature studies in LiF:Mg,Cu,P
    Mathur, VK
    Bandyopadhyay, PK
    Barkyoumb, JH
    Cai, GG
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 103 - 106
  • [38] DOSE REASSESSMENT OF LIF-MG,CU,P
    DRISCOLL, CMH
    RADIATION PROTECTION DOSIMETRY, 1987, 19 (01) : 59 - 61
  • [39] Low temperature radioluminescence of LiF:Mg,Cu,P
    Kurt, K.
    Mathur, V. K.
    McKeever, S. W. S.
    Townsend, P. D.
    Valberg, L.
    RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 134 - 138
  • [40] Role of impurities in the thermoluminescence of LiF:Mg,Cu,P
    Chen, TC
    Stoebe, TG
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 243 - 246