Screening of abnormal LiF:Mg,Cu,P glow curves

被引:1
|
作者
Bautro, N
Cassata, J
Rotunda, JE
机构
[1] John R Marsh Canc Ctr, Hagerstown, MD 21742 USA
[2] USN, Dosimetry Ctr, Bethesda, MD 20889 USA
[3] St Gobain Ind Ceram Inc, Biocron NE Div, Solon, OH 44139 USA
关键词
D O I
10.1093/oxfordjournals.rpd.a032762
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A process to screen electronically abnormal LiF:Mg,Cu,P glow curves in routine dosimetry is proposed. The method is based on the fact that when a glow curve is normalised to a part of the integral of the glow curve it loses its dependence on the magnitude of the exposure. This characteristic allows a glow curve from a dosemeter exposed in the field to be compared with an 'ideal' glow curve from the same dosemeter. A difference curve is generated from the differences between the normalised 'ideal' and the normalised field curves. This difference curve can be used to identify the abnormal characteristics of the field-generated glow curve and, since both normalised curves are essentially the same, the anomalies can be resolved by reconstructing the field curve to match the 'ideal' curve.
引用
收藏
页码:387 / 391
页数:5
相关论文
共 50 条
  • [41] Characteristics of LiF:Mg,Cu,P for clinical applications
    Ginjaume, M
    Ortega, X
    Duch, MA
    Jornet, N
    Sánchez-Reyes, A
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 389 - 391
  • [42] Defect mechanisms in the thermoluminescence of LiF:Mg, Cu, P
    Mahajna, S
    Yossian, D
    Horowitz, YS
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 1995, 136 (1-4): : 181 - 185
  • [43] Personnel dosimetry using LiF:Mg,Cu,P
    Moscovitch, M
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 49 - 56
  • [44] Low temperature studies in LiF:Mg,Cu,P
    Mathur, VK
    Bandyopadhyay, PK
    Barkyoumb, JH
    Cai, GG
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 103 - 106
  • [45] Studies on the thermoluminescence spectra and thermal stability of LiF:Mg,Cu, LiF:Mg,Cu,Na and LiF:Mg,Cu,Si
    Yang, B
    Lu, Q
    Wang, S
    Townsend, PD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 239 (03): : 171 - 178
  • [46] Analysis of the glow curves obtained from LiF:Mg,Cu,Na,Si TL material using the general order kinetics model
    Lee, JI
    Kim, JL
    Chang, SY
    Nam, YM
    Chung, KS
    Choe, HS
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 341 - 344
  • [47] A HIGH-SENSITIVITY LIF THERMOLUMINESCENT DOSIMETER - LIF(MG, CU, P)
    WU, DK
    SUN, FY
    DAI, HC
    HEALTH PHYSICS, 1984, 46 (05): : 1063 - 1067
  • [48] Analysis of the glow curves obtained from LiF:Mg,Cu,Na,Si TL material using the general order kinetics model
    Lee, JI
    Kim, JL
    Chang, SY
    Nam, YM
    Chung, KS
    Choe, HS
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 341 - 344
  • [49] Further study on the influence of thermal treatments on the glow curve structure in LiF:Mg,Cu,P (GR-200A)
    Tang, K.
    Fan, H.
    Cui, H.
    Zhu, H.
    Liu, Z.
    RADIATION MEASUREMENTS, 2014, 63 : 1 - 5
  • [50] Dependence of LiF:Mg,Cu,P (MCP-N) glow curve structure on dopant composition and thermal treatment
    Bilski, P
    Budzanowski, M
    Olko, P
    RADIATION PROTECTION DOSIMETRY, 1997, 69 (03) : 187 - 198