Low temperature radioluminescence of LiF:Mg,Cu,P

被引:7
|
作者
Kurt, K.
Mathur, V. K.
McKeever, S. W. S.
Townsend, P. D.
Valberg, L.
机构
[1] Univ Sussex, Brighton BN1 9QH, E Sussex, England
[2] USN, Warfare Ctr, Carderock Div, Bethesda, MD 20817 USA
[3] Oklahoma State Univ, Dept Phys, Stillwater, OK 74078 USA
关键词
D O I
10.1093/rpd/nci658
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Low temperature radioluminescence spectra of LiF, variously co-doped with Mg, Cu and P, show highly unusual temperature dependencies which resemble thermoluminescence data. The signals include intense peaks and a relatively weak continuous background. One peak occurs below 30 K, together with a major peak near 125 K. The signals are highly sensitive to the dopants and slightly sensitive to X-ray dose rate. The role of donor acceptor pairs and the perturbations from intrinsic defects formed by ionisation can be used to describe all the observations. The 290 nm emission band is linked to H center annealing.
引用
收藏
页码:134 / 138
页数:5
相关论文
共 50 条
  • [1] Low temperature studies in LiF:Mg,Cu,P
    Mathur, VK
    Bandyopadhyay, PK
    Barkyoumb, JH
    Cai, GG
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 103 - 106
  • [2] Low temperature studies in LiF:Mg,Cu,P
    Mathur, VK
    Bandyopadhyay, PK
    Barkyoumb, JH
    Cai, GG
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 103 - 106
  • [3] Comparison between the low temperature thermoluminescence spectra in annealed LiF:Mg,Cu, LiF:Mg,Cu,P and LiF:Mg,Cu,Si
    Yang, B.
    Wang, L.
    Townsend, P. D.
    Gao, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (11): : 2581 - 2586
  • [4] Low temperature thermoluminescence of annealed LiF:Mg, Cu, P
    Yang, B
    Gao, H
    Townsend, PD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 247 (02): : 324 - 330
  • [5] A competitive radioluminescence material - LiF:Mg,Cu,P for real-time dosimetry
    Zhang, Siyuan
    Tang, Kaiyong
    Fan, Haijun
    Fu, Li
    RADIATION MEASUREMENTS, 2022, 151
  • [7] Role of dopants in LiF:Mg,Cu, LiF:Mg,P and LiF:Mg,Cu,P detectors
    Mohammadi, Kh
    Zarandi, A. Moussavi
    Afarideh, H.
    Shahmaleki, S.
    JOURNAL OF SOLID STATE CHEMISTRY, 2013, 202 : 282 - 290
  • [8] Optical and thermoluminescence properties of LiF:Cu, LiF:Mg,Cu and LiF:Mg,Cu,P single crystals
    Chernov, V
    Mironenko, S
    Rogalev, B
    Bos, AJJ
    de Haas, JTM
    Delgado, A
    RADIATION MEASUREMENTS, 1998, 29 (3-4) : 365 - 372
  • [9] A study on thermal degradation of LiF:Mg,Cu,P and LiF:Mg,Cu,Si
    Konnai, Akiko
    Ozasa, Naoto
    Lee, Jung-il
    RADIATION MEASUREMENTS, 2010, 45 (3-6) : 533 - 536
  • [10] An improved LiF:Mg,Cu,P chip with a low residual signal
    Tang, K
    Cai, G
    Shen, W
    Min, L
    Zhu, H
    RADIATION PROTECTION DOSIMETRY, 1999, 84 (1-4) : 227 - 229