VOLTAMMETRIC DETERMINATION OF ROPINIROLE AT GLASSY CARBON ELECTRODE EMPLOYING PULSED TECHNIQUES

被引:0
|
作者
Bozal-Palabiyik, Burcin [1 ]
Uslu, Bengi [1 ]
机构
[1] Ankara Univ, Fac Pharm, Dept Analyt Chem, TR-06100 Ankara, Turkey
关键词
ropinirole; glassy carbon electrode; voltammetry; drug analysis; validation; PHARMACEUTICAL DOSAGE FORMS; LIQUID-CHROMATOGRAPHY; PARKINSONS-DISEASE; PASTE ELECTRODE; HUMAN PLASMA; HUMAN SERUM; DRUG; NANOPARTICLES; VALIDATION; IMPURITIES;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study electrochemical studies were performed for ropinirole, which is used for the treatment of Parkinson's disease. In order to obtain rapid, simple and repeatable determination for ropinirole at glassy carbon electrode differential pulse voltammetry and square wave voltammetry were used. The oxidation behavior of this drug was analyzed with different supporting electrolytes between pH 0.3 - 12.0 by using cyclic voltammetry, differential pulse voltammetry and square wave voltammetry. The regression and the required validation parameters were studied in 0.1 M H2SO4 and pH 7.0 Britton-Robinson buffer solutions. Linearity was found between 8x10(-6) M and 2x10(-4) M for differential pulse and 4x10(-6) M and 2x10(-4) M for square wave voltammetry in 0.1 M H2SO4 with detection limits of 1.06x10(-6) M and 1.04x10(-6) M, respectively. Linear range was found 2x10(-6) - 6x10(-5) M for differential pulse and 4x10(-6) - 6x10(-5) M for square wave voltammetry in pH 7.0 BrittonRobinson buffer solution with detection limits of 4.73x10(-7) M and 2.65x10(-7) M, respectively. The applicability of developed techniques was shown through analyzing from pharmaceutical dosage forms and serum samples as well. Average recovery values were found between 99.65 % - 100.55 % which showed the accuracy of the developed techniques.
引用
收藏
页码:559 / 567
页数:9
相关论文
共 50 条
  • [22] Voltammetric Determination of Codeine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
    Piech, Robert
    Rumin, Martyna
    Paczosa-Bator, Beata
    [J]. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2015, 2015
  • [23] Anodic Adsorptive Stripping Voltammetric Determination of Rafoxanide on Glassy Carbon Electrode
    Radi, Abd-elgawad
    El-samboskany, Hassan
    [J]. COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2020, 23 (10) : 1002 - 1009
  • [24] Voltammetric Determination of Tenoxicam in Drug Formulation at Modified Glassy Carbon Electrode
    Sadikoglu, Murat
    Cabuk, Ahmet
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (05): : 4508 - 4519
  • [25] Selective and Highly Sensitive Voltammetric Determination of Citalopram with Glassy Carbon Electrode
    Madej, Maria
    Kochana, Jolanta
    Bas, Boguslaw
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (08) : H359 - H369
  • [26] Voltammetric Determination of Epinephrine using a Thiourea Modified Glassy Carbon Electrode
    Yazdely, Malihe Ahmadian
    Taher, Mohammad Ali
    Tajik, Somayeh
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2013, 5 (04): : 517 - 527
  • [27] VOLTAMMETRIC DETERMINATION OF BENZIDINE AND ITS DERIVATIVES, AT A GLASSY-CARBON ELECTRODE
    BAREK, J
    BERKA, A
    TOCKSTEINOVA, Z
    ZIMA, J
    [J]. TALANTA, 1986, 33 (10) : 811 - 815
  • [28] VOLTAMMETRIC DETERMINATION OF TOTAL ALKANNIN USING A GLASSY-CARBON ELECTRODE
    CHAISUKSANT, R
    VOULGAROPOULOS, A
    MELLIDIS, AS
    PAPAGEORGIOU, VP
    [J]. ANALYST, 1993, 118 (02) : 179 - 182
  • [29] Diaminoanthraquinone polymer modified glassy carbon electrode for the voltammetric determination of imidacloprid
    Soman, Sithara
    Ramakrishnan, Kala
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2024, 54 (12) : 2831 - 2843
  • [30] Application of double disc glassy carbon electrode for voltammetric determination of viloxazine
    Madej, Maria
    Kochana, Jolanta
    Bas, Boguslaw
    [J]. PROCEEDINGS OF THE 15TH INTERNATIONAL STUDENTS CONFERENCE MODERN ANALYTICAL CHEMISTRY, 2019, : 98 - 103