Voltammetric Determination of Codeine on Glassy Carbon Electrode Modified with Nafion/MWCNTs

被引:5
|
作者
Piech, Robert [1 ]
Rumin, Martyna [1 ]
Paczosa-Bator, Beata [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, PL-30059 Krakow, Poland
关键词
ASCORBIC-ACID; HUMAN-PLASMA; FORMULATIONS; PARACETAMOL; OXIDATION; PHOSPHATE; MORPHINE; URINE;
D O I
10.1155/2015/626458
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glassy carbon electrode modified with a Nafion/MWCNTs composite is shown to enable the determination of codeine using differential pulse voltammetry in phosphate buffer of pH 3.0. At a preconcentration time of 15 s, the calibration graph is linear in the 0.5 mu M (0.15 mg.L-1) to 15 mu M (4.5 mg.L-1) concentration range with a correlation coefficient of 0.998. The detection limit at a preconcentration time of 120 s is as low as 4.5 mu g.L-1. The repeatability of the method at a 0.6 mu g.L-1 concentration level, expressed as the RSD, is 3.7% (for n = 5). The method was successfully applied and validated by analyzing codeine in drug, human plasma, and urine samples.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] APPLICATION OF GLASSY CARBON ELECTRODE MODIFIED WITH NAFION/MWCNTS FOR SENSITIVE VOLTAMMETRIC DETERMINATION OF THYMOL
    Piech, Robert
    Paczosa-Bator, Beata
    [J]. ACTA POLONIAE PHARMACEUTICA, 2015, 72 (06): : 1081 - 1088
  • [2] High Sensitive Voltammetric Determination of Paroxetine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
    Piech, Robert
    Rumin, Martyna
    Paczosa-Bator, Beata
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (12): : 7528 - 7539
  • [3] Electrochemical Behavior and Voltammetric Determination of Theophylline at a Glassy Carbon Electrode Modified with Graphene/Nafion
    Li, Yamin
    Wu, Shufang
    Luo, Peili
    Liu, Jie
    Song, Ge
    Zhang, Kai
    Ye, Baoxian
    [J]. ANALYTICAL SCIENCES, 2012, 28 (05) : 497 - 502
  • [4] Electrochemical Behavior and Voltammetric Determination of Theophylline at a Glassy Carbon Electrode Modified with Graphene/Nafion
    Yamin Li
    Shufang Wu
    Peili Luo
    Jie Liu
    Ge Song
    Kai Zhang
    Baoxian Ye
    [J]. Analytical Sciences, 2012, 28 : 497 - 502
  • [5] Pulse anodic stripping voltammetric determination of copper with an amoxicillin–nafion modified glassy carbon electrode
    A. A. Ramadan
    H. Mandil
    M. A. Saleh
    [J]. Journal of Applied Electrochemistry, 2008, 38 : 1715 - 1720
  • [6] Voltammetric Determination of Arsenic with Modified Glassy Carbon Electrode
    Stankovic, Anamarija
    Kajinic, Zana
    Turkalj, Jelena Vesligaj
    Romic, Zeljka
    Sikiric, Maja Dutour
    Asserghine, Abdelilah
    Nagy, Geza
    Medvidovic-Kosanovic, Martina
    [J]. ELECTROANALYSIS, 2020, 32 (05) : 1043 - 1051
  • [7] Electrochemical behavior and voltammetric determination of norfloxacin at glassy carbon electrode modified with multi walled carbon nanotubes/Nafion
    Huang, Ke-Jing
    Liu, Xue
    Xie, Wan-Zhen
    Yuan, Hong-Xia
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2008, 64 (02) : 269 - 274
  • [8] Voltammetric determination of L-dopa using a carbon nanotubes-Nafion modified glassy carbon electrode
    Xiang, Cuili
    Zou, Yongjin
    Xie, Jingjing
    Fei, Ximing
    [J]. ANALYTICAL LETTERS, 2006, 39 (13) : 2569 - 2579
  • [9] Voltammetric behavior and determination of estrogens at Nafion-modified glassy carbon electrode in the presence of cetyltrimethylammonium bromide
    Hu, SS
    Wu, KB
    Yi, HC
    Cui, DF
    [J]. ANALYTICA CHIMICA ACTA, 2002, 464 (02) : 209 - 216
  • [10] Differential pulse adsorptive stripping voltammetric determination of benzocaine and butacaine with Nafion modified glassy carbon electrode
    Reddy, Tukiakula Madhusudana
    Balaji, Kodigutta
    Reddy, Srinivasulu Jayarama Reddy
    [J]. CROATICA CHEMICA ACTA, 2006, 79 (02) : 253 - 259