Voltammetric Determination of Codeine on Glassy Carbon Electrode Modified with Nafion/MWCNTs

被引:5
|
作者
Piech, Robert [1 ]
Rumin, Martyna [1 ]
Paczosa-Bator, Beata [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, PL-30059 Krakow, Poland
关键词
ASCORBIC-ACID; HUMAN-PLASMA; FORMULATIONS; PARACETAMOL; OXIDATION; PHOSPHATE; MORPHINE; URINE;
D O I
10.1155/2015/626458
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glassy carbon electrode modified with a Nafion/MWCNTs composite is shown to enable the determination of codeine using differential pulse voltammetry in phosphate buffer of pH 3.0. At a preconcentration time of 15 s, the calibration graph is linear in the 0.5 mu M (0.15 mg.L-1) to 15 mu M (4.5 mg.L-1) concentration range with a correlation coefficient of 0.998. The detection limit at a preconcentration time of 120 s is as low as 4.5 mu g.L-1. The repeatability of the method at a 0.6 mu g.L-1 concentration level, expressed as the RSD, is 3.7% (for n = 5). The method was successfully applied and validated by analyzing codeine in drug, human plasma, and urine samples.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Voltammetric Determination of Lead and Copper in Wine by Modified Glassy Carbon Electrode
    Vesna Antunović
    Tatjana Tripković
    Biljana Tomašević
    Rada Baošić
    Dijana Jelić
    Aleksandar Lolić
    [J]. Analytical Sciences, 2021, 37 (2) : 353 - 358
  • [42] Simultaneous voltammetric determination of paracetamol and domperidone based on a graphene/platinum nanoparticles/nafion composite modified glassy carbon electrode
    Kalambate, Pramod K.
    Sanghavi, Bankim J.
    Karna, Shashi P.
    Srivastava, Ashwini K.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 213 : 285 - 294
  • [43] MWNT/Nafion composite modified glassy carbon electrode as the voltammetric sensor for sensitive determination of 8-hydroxyquinoline in cosmetic
    Guo, Sujuan
    Wu, Xianli
    Zhou, Jing
    Wang, Jing
    Yang, Baocheng
    Ye, Baoxian
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 655 (01) : 45 - 49
  • [44] Sensitive voltammetric sensor of dihydromyricetin based on Nafion/SWNT-modified glassy carbon electrode
    Xu, Ying
    Wang, Fei
    Wang, Le
    Zhao, Fangyuan
    Yang, Baocheng
    Ye, Baoxian
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (04) : 1473 - 1480
  • [45] Sensitive voltammetric sensor of dihydromyricetin based on Nafion/SWNT-modified glassy carbon electrode
    Ying Xu
    Fei Wang
    Le Wang
    Fangyuan Zhao
    Baocheng Yang
    Baoxian Ye
    [J]. Journal of Solid State Electrochemistry, 2012, 16 : 1473 - 1480
  • [46] Electrochemical determination of bisphenol A based on PHD/MWCNTs modified glassy carbon electrode
    Yi, Jie
    Tang, Shuai
    Wang, Zhou
    Yin, Yefeng
    Yang, Sui
    Zhang, Bingxing
    Shu, Shi
    Liu, Tingya
    Xu, Lu
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2015, 95 (02) : 158 - 174
  • [47] Voltammetric determination of niclosamide at a glassy carbon electrode
    Alemu, H
    Wagana, P
    Tseki, PF
    [J]. ANALYST, 2002, 127 (01) : 129 - 134
  • [48] VOLTAMMETRIC DETERMINATION OF NEPTUNIUM AT GLASSY CARBON ELECTRODE
    PLOCK, CE
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1968, 18 (03): : 289 - &
  • [49] Voltammetric determination of paracetamol on the glassy carbon electrode
    毕淑云
    王桂芬
    朴元哲
    王大力
    殷晓萍
    [J]. 延边大学学报(自然科学版), 2000, (02) : 110 - 112
  • [50] Voltammetric Determination of Caffeine at Pt/Carbon Nanotubes Composite Modified Glassy Carbon Electrode
    Wei, Yingliang
    Zhang, Luping
    Shao, Chen
    Li, Chao
    [J]. CHEMIA ANALITYCZNA, 2009, 54 (04): : 607 - 617