Simultaneous voltammetric determination of paracetamol and domperidone based on a graphene/platinum nanoparticles/nafion composite modified glassy carbon electrode

被引:98
|
作者
Kalambate, Pramod K. [1 ]
Sanghavi, Bankim J. [2 ]
Karna, Shashi P. [3 ]
Srivastava, Ashwini K. [1 ]
机构
[1] Univ Bombay, Dept Chem, Bombay 400098, Maharashtra, India
[2] Univ Virginia, Dept Elect & Comp Engn, Charlottesville, VA 22904 USA
[3] US Army Res Lab, Weap & Mat Res Directorate, Aberdeen Proving Ground, MD 21005 USA
关键词
Paracetamol; Domperidone; Graphene; Platinum nanoparticles; Electrodeposition; Nafion; POTENTIOMETRIC STRIPPING ANALYSIS; ELECTROCHEMICAL DETERMINATION; BIOMIMETIC SENSOR; GRAPHENE OXIDE; ACETAMINOPHEN; NANOCOMPOSITE; FORMULATIONS; FABRICATION; REDUCTION; TYROSINE;
D O I
10.1016/j.snb.2015.02.090
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Graphene oxide and hexachloroplatinic acid were electrochemically reduced on a glassy carbon electrode (GCE) surface so as to form a graphene (Gr)-platinum nanoparticles (PtNP) composite. This nano composite was then coated with nafion (NAF) film so as to form NAF/PtNP/Gr/GCE. In this work, an electrochemical method based on adsorptive stripping square wave voltammetry (AdSSWV) employing NAF/PtNP/Gr/GCE has been proposed for the subnanomolar determination of paracetamol (PCT) and domperidone (DOM) simultaneously. The electrode material was characterized by scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction. The electrochemical performance of PCT and DOM on modified electrode was investigated by cyclic voltammetry, electrochemical impedance spectroscopy, and chronocoulometry. A sixteen fold enhancement in the AdSSWV signal was observed at NAF/PtNP/Gr/GCE in pH 6.0, phosphate buffer, as compared to GCE. Under the optimized conditions, the method allowed simultaneous determination of PCT and DOM in the linear working range of 8.2 x 10(-6)-1.6 x 10(-9) M with detection limits (3 x SD/s) of 1.06 x 10(-10) and 4.37 x 10(-10) M for PCT and DOM respectively. The practical analytical utilities of the modified electrode were demonstrated by the determination of PCT and DOM in pharmaceutical formulations, human urine, and blood serum samples. This proposed method was validated by HPLC and the results are in agreement at the 95% confidence level. Simultaneous voltammetric determination of PCT and DOM has been reported for the first time. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:285 / 294
页数:10
相关论文
共 50 条
  • [1] Voltammetric determination of sumatriptan based on a graphene/gold nanoparticles/Nafion composite modified glassy carbon electrode
    Sanghavi, Bankim J.
    Kalambate, Pramod K.
    Karna, Shashi P.
    Srivastava, Ashwini K.
    [J]. TALANTA, 2014, 120 : 1 - 9
  • [2] Graphene/Nafion composite film modified glassy carbon electrode for simultaneous determination of paracetamol, aspirin and caffeine in pharmaceutical formulations
    Yigit, Aydin
    Yardim, Yavuz
    Celebi, Metin
    Levent, Abdulkadir
    Senturk, Zuhre
    [J]. TALANTA, 2016, 158 : 21 - 29
  • [3] Electrochemical behavior and voltammetric determination of paracetamol on Nafion/TiO2-graphene modified glassy carbon electrode
    Fan, Yang
    Liu, Jin-Hang
    Lu, Hai-Ting
    Zhang, Qin
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 85 (02) : 289 - 292
  • [4] Electrochemical Behavior and Voltammetric Determination of Theophylline at a Glassy Carbon Electrode Modified with Graphene/Nafion
    Li, Yamin
    Wu, Shufang
    Luo, Peili
    Liu, Jie
    Song, Ge
    Zhang, Kai
    Ye, Baoxian
    [J]. ANALYTICAL SCIENCES, 2012, 28 (05) : 497 - 502
  • [5] Electrochemical Behavior and Voltammetric Determination of Theophylline at a Glassy Carbon Electrode Modified with Graphene/Nafion
    Yamin Li
    Shufang Wu
    Peili Luo
    Jie Liu
    Ge Song
    Kai Zhang
    Baoxian Ye
    [J]. Analytical Sciences, 2012, 28 : 497 - 502
  • [6] Nafion-graphene composite film modified glassy carbon electrode for voltammetric determination of p-aminophenol
    Hayati Filik
    Gamze Çetintaş
    Serkan Naci Koç
    Handan Gülce
    İsmail Boz
    [J]. Russian Journal of Electrochemistry, 2014, 50 : 243 - 252
  • [7] Nafion-Graphene Composite Film Modified Glassy Carbon Electrode for Voltammetric Determination of p-Aminophenol
    Filik, Hayati
    Cetintas, Gamze
    Koc, Serkan Naci
    Gulce, Handan
    Boz, Ismail
    [J]. RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (03) : 243 - 252
  • [8] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Fangyuan Zhao
    Fei Wang
    Weining Zhao
    Jing Zhou
    Yang Liu
    Lina Zou
    Baoxian Ye
    [J]. Microchimica Acta, 2011, 174 : 383 - 390
  • [9] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Zhao, Fangyuan
    Wang, Fei
    Zhao, Weining
    Zhou, Jing
    Liu, Yang
    Zou, Lina
    Ye, Baoxian
    [J]. MICROCHIMICA ACTA, 2011, 174 (3-4) : 383 - 390
  • [10] Voltammetric Sensing of Bilirubin Based on Nafion/Electrochemically Reduced Graphene Oxide Composite Modified Glassy Carbon Electrode
    Avan, Asiye Aslihan
    Aydar, Sevda
    Filik, Hayati
    [J]. CURRENT ANALYTICAL CHEMISTRY, 2015, 11 (02) : 96 - 103