High Sensitive Voltammetric Determination of Paroxetine on Glassy Carbon Electrode Modified with Nafion/MWCNTs

被引:0
|
作者
Piech, Robert [1 ]
Rumin, Martyna [1 ]
Paczosa-Bator, Beata [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, PL-30059 Krakow, Poland
来源
关键词
Paroxetine; MWCNTs; Nafion; Voltammetry; SEROTONIN REUPTAKE INHIBITORS; PHARMACEUTICAL FORMULATIONS; METABOLITES; CHROMATOGRAPHY; SERTRALINE;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A glassy carbon electrode modified with a Nafion-MWCNT composite is shown to enable the high sensitive determination of paroxetine using differential pulse voltammetry in phosphate buffer of pH 6.5. At a preconcentration time of 15 s, the calibration graph is linear in the 0.1 mu M (0.033 mg.L-1) to 2.5 mu M (0.82 mg.L-1) concentration range with a correlation coefficient of 0.998. The detection limit at a preconcentration time of 60 s is as low as 2.6 mu g.L-1. The repeatability of the method at a 0. 16 mg.L-1 concentration level, expressed as the RSD, is 4.1% (for n = 5). The method was successfully applied and validated by analyzing paroxetine in drug and urine samples.
引用
收藏
页码:7528 / 7539
页数:12
相关论文
共 50 条
  • [1] APPLICATION OF GLASSY CARBON ELECTRODE MODIFIED WITH NAFION/MWCNTS FOR SENSITIVE VOLTAMMETRIC DETERMINATION OF THYMOL
    Piech, Robert
    Paczosa-Bator, Beata
    [J]. ACTA POLONIAE PHARMACEUTICA, 2015, 72 (06): : 1081 - 1088
  • [2] Voltammetric Determination of Codeine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
    Piech, Robert
    Rumin, Martyna
    Paczosa-Bator, Beata
    [J]. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2015, 2015
  • [3] Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples
    Yang, Suling
    Qu, Lingbo
    Yang, Ran
    Li, Jianjun
    Yu, Lanlan
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (07) : 1371 - 1378
  • [4] Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples
    Suling Yang
    Lingbo Qu
    Ran Yang
    Jianjun Li
    Lanlan Yu
    [J]. Journal of Applied Electrochemistry, 2010, 40 : 1371 - 1378
  • [5] Electrochemical Behavior and Voltammetric Determination of Theophylline at a Glassy Carbon Electrode Modified with Graphene/Nafion
    Li, Yamin
    Wu, Shufang
    Luo, Peili
    Liu, Jie
    Song, Ge
    Zhang, Kai
    Ye, Baoxian
    [J]. ANALYTICAL SCIENCES, 2012, 28 (05) : 497 - 502
  • [6] Electrochemical Behavior and Voltammetric Determination of Theophylline at a Glassy Carbon Electrode Modified with Graphene/Nafion
    Yamin Li
    Shufang Wu
    Peili Luo
    Jie Liu
    Ge Song
    Kai Zhang
    Baoxian Ye
    [J]. Analytical Sciences, 2012, 28 : 497 - 502
  • [7] Sensitive voltammetric sensor of dihydromyricetin based on Nafion/SWNT-modified glassy carbon electrode
    Xu, Ying
    Wang, Fei
    Wang, Le
    Zhao, Fangyuan
    Yang, Baocheng
    Ye, Baoxian
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (04) : 1473 - 1480
  • [8] Sensitive voltammetric sensor of dihydromyricetin based on Nafion/SWNT-modified glassy carbon electrode
    Ying Xu
    Fei Wang
    Le Wang
    Fangyuan Zhao
    Baocheng Yang
    Baoxian Ye
    [J]. Journal of Solid State Electrochemistry, 2012, 16 : 1473 - 1480
  • [9] MWNT/Nafion composite modified glassy carbon electrode as the voltammetric sensor for sensitive determination of 8-hydroxyquinoline in cosmetic
    Guo, Sujuan
    Wu, Xianli
    Zhou, Jing
    Wang, Jing
    Yang, Baocheng
    Ye, Baoxian
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 655 (01) : 45 - 49
  • [10] Pulse anodic stripping voltammetric determination of copper with an amoxicillin–nafion modified glassy carbon electrode
    A. A. Ramadan
    H. Mandil
    M. A. Saleh
    [J]. Journal of Applied Electrochemistry, 2008, 38 : 1715 - 1720