Diaminoanthraquinone polymer modified glassy carbon electrode for the voltammetric determination of imidacloprid

被引:0
|
作者
Soman, Sithara [1 ]
Ramakrishnan, Kala [1 ,2 ]
机构
[1] Cochin Univ Sci & Technol, Dept Appl Chem, Kochi 682022, Kerala, India
[2] Cochin Univ Sci & Technol, Inter Univ Ctr Nanomat & Devices IUCND, Kochi 682022, Kerala, India
关键词
Imidacloprid; Electropolymerization; Redox polymer; Cyclic voltammetry; Pesticide sensing; Electrochemical sensing; GRAPHENE OXIDE; ELECTROCHEMICAL DETERMINATION; SENSOR; POLY(1,5-DIAMINOANTHRAQUINONE);
D O I
10.1007/s10800-024-02145-5
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A simple electrochemical sensor was developed towards the widely used insecticide Imidacloprid (IMI) using a redox active polymer, poly(1,5-diaminoanthraquinone) (PDAAQ) modified glassy carbon electrode (GCE). The electro catalytic reduction of IMI was obtained using the GCE/PDAAQ electrode in phosphate buffer solution having pH 7. The irreversible reduction of IMI occurs at a potential of -1.031 V with a slight shift towards negative potential with increase in concentration of IMI. The linear range obtained is 9.98 x 10-6 to 6.6 x 10-4 M with a limit of detection 2.95 x 10-7 M. Repeatability and reproducibility of the sensor was checked and was found to be in the acceptable range with relative standard deviation less than 5%. Selectivity of the sensor was studied in presence of various metal ions and organic molecules and found that there is no significant interference. IMI analysis was done using spike recovery tests in well water and cucumber juice samples which shows that the developed sensor can be successfully applied to the trace determination of IMI in real samples.
引用
收藏
页码:2831 / 2843
页数:13
相关论文
共 50 条
  • [1] Voltammetric Determination of Arsenic with Modified Glassy Carbon Electrode
    Stankovic, Anamarija
    Kajinic, Zana
    Turkalj, Jelena Vesligaj
    Romic, Zeljka
    Sikiric, Maja Dutour
    Asserghine, Abdelilah
    Nagy, Geza
    Medvidovic-Kosanovic, Martina
    [J]. ELECTROANALYSIS, 2020, 32 (05) : 1043 - 1051
  • [2] VOLTAMMETRIC DETERMINATION OF RUPATADINE AT GRAPHENE MODIFIED GLASSY CARBON ELECTRODE
    Devnani, H.
    Singh, P.
    Saxena, S.
    Satsangee, S. P.
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2014, 5 (11):
  • [3] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Beigmoradi, Fariba
    Beitollahi, Hadi
    [J]. SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2024, 60 (01) : 15 - 23
  • [4] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    [J]. Surface Engineering and Applied Electrochemistry, 2024, 60 : 15 - 23
  • [5] Voltammetric Determination of Bergenin with Graphene Modified Glassy Carbon Electrode
    Li, Xiaobao
    Zou, Ruyi
    Niu, Yanyan
    Shao, Taiming
    Chen, Yong
    Sun, Wei
    He, Mengxiong
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (02): : 1976 - 1984
  • [6] Voltammetric determination of disinfectants at multiwalled carbon nanotube modified glassy carbon electrode
    Baranowska, I.
    Bijak, K.
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (10) : 891 - 895
  • [7] Voltammetric determination of disinfectants at multiwalled carbon nanotube modified glassy carbon electrode
    I. Baranowska
    K. Bijak
    [J]. Journal of Analytical Chemistry, 2013, 68 : 891 - 895
  • [9] Voltammetric Determination of Codeine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
    Piech, Robert
    Rumin, Martyna
    Paczosa-Bator, Beata
    [J]. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2015, 2015
  • [10] Voltammetric Determination of Tenoxicam in Drug Formulation at Modified Glassy Carbon Electrode
    Sadikoglu, Murat
    Cabuk, Ahmet
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (05): : 4508 - 4519